• Title/Summary/Keyword: UV illuminance

Search Result 6, Processing Time 0.02 seconds

Study on the UV illuminance to improve on attraction effect of fluorescent bait cage for pots (통발용 형광 미끼통의 유인 효과 개선을 위한 자외선 조도에 관한 연구)

  • Chang, Ho-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.4
    • /
    • pp.316-326
    • /
    • 2011
  • In this study, the entrapped number is investigated on the UV light with different illuminance to fluorescent bait cage for swimming crab in order to find the appropriate illuminance which has the best attraction effect of fluorescent bait cage for pots. In addition, preference to the light, arrival time and residence time at light area are compared and analyzed to fluorescent bait cage and non-fluorescent bait cage for American lobster at the UV light and ordinary light according to the illuminance condition. Pot with red non-fluorescent bait cage at the no lighting (<0.01lux), pot with blue fluorescent bait cage at the 20W UV lighting (0.16lux) and pot with blue fluorescent bait cage at the 30W UV lighting (0.22lux) were soaked for 6 hours and the entrapped number of swimming crab was examined. The mean entrapped number of swimming crab in pot with red non-fluorescent bait cage at the no lighting (<0.01lux) was 1.0, but the mean entrapped number of swimming crab in pot with blue fluorescent bait cages at the 20W UV lighting (0.16lux) and 30W UV lighting (0.22lux) were 1.4 and 0.4, respectively (P<0.05). The rate of preference to the blue fluorescent bait cage at the UV lighting shows 1.6-4.8 times higher than that of preference to the red non-fluorescent bait cage at the ordinary lighting. In addition, The rate of preference to the blue fluorescent bait cage at the UV lighting is higher when the illuminance of ordinary light is same as or is lower than that of UV light (P<0.05). However, the preference to the light depending on gender shows no significant difference (P>0.05). The arrival time to UV light area of lobster is shown as 1.2-2.4 times faster than that to ordinary light area. Generally, it is shown that arrival time to UV light area is faster than the arrival time to ordinary light area when the illuminance of ordinary light is the same as or lower than that of UV light (P<0.05). However, arrival time to the light area depending on gender shows no significant difference (P>0.05). The residence time at UV light area of lobster is 1.2-1.7 times longer than that at ordinary light area. The residence time depending on different illuminance of ordinary light and genders showed no significant difference (P>0.05).

A study on the Design and Application of a TIR Lens for Realizing A Compact Spot-Type UV Curing Machine Optical System (컴팩트한 Spot형 UV 경화기 광학계를 구현하기 위한 TIR 렌즈 설계 및 응용에 관한 연구)

  • Kim, Yu-Rim;Heo, Seung-Ye;Lee, Sang-Wook;Kim, Wan-Chin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.255-264
    • /
    • 2022
  • The conventional spot-type UV curing machine configures a collimator optical system using a plurality of lenses so that the light beam is incident through an optical cable. In order to increase the transmission light efficiency, a collimator optical system composed of three or more lenses is required, and accordingly, it is difficult to align the optical system, and it is difficult to implement the system compactly. In this study, a single TIR lens collimator that can realize the same level of spot diameter and light efficiency as the conventional collimator optical system composed of three lenses was designed. Through this, the light efficiency at the curing area with the minimum illuminance deviation was 33.2 %, which was similar to the performance of the reference collimator optical system, and the illuminance deviation on the curing area was 18.8 %, ensuring acceptable performance. In addition, by arranging a fly-eye lens with field flattening function at the front end of the condensing lens, the effective curing area diameter was reduced from 5.0 mm to 3.0 mm, enabling higher curing energy density to be realized. In addition, it was confirmed that the illuminance deviation can be greatly improved to a level of 14.4%.

Design of a Bar-type TIR Lens Having a Freeform Surface for Forming a Line Beam Using an LED Light Source (LED 광원 사용 시 line beam 형성을 위한 자유 곡면 bar type의 TIR lens 설계)

  • Seo, Jin-Hee;Lee, Jeong-Su;Kim, Seo-Young;Jeong, You-Jin;Park, Hye-Jin;Nam, Deuk-Young;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.295-303
    • /
    • 2017
  • In this paper, we have studied a method of forming a line beam using a UV LED. The existing linear-type UV LED curing optical system is composed of several cylindrical lenses, but problems such as optical system alignment, enlargement of the module, efficiency, etc. may arise in the future. As an alternative to these problems, a bar-type TIR lens having a freeform surface only in the y-axis direction is designed, to verify that it shows advantages in maximum illuminance, uniformity of illuminance, and flux efficiency.

Effect of Climatic Conditions on Pollination Behavior of Honeybees (Apis mellifera L.) in the Greenhouse Cultivation of Watermelon (Citrullus lanatus L.)

  • Lee, Kyeong Yong;Lim, Jeonghyeon;Yoon, Hyung Joo;Ko, Hyeon-Jin
    • Journal of Apiculture
    • /
    • v.33 no.4
    • /
    • pp.239-250
    • /
    • 2018
  • We investigated the pollination activity of honeybees (Apis mellifera L.) in terms of different climatic conditions in the greenhouse cultivation of watermelons (Citrullus lanatus L.) during winter. The aim of the study was to search a climatic condition which effectively can be use honeybees as pollinators during the flowering season of watermelons in winter or early spring. The average climatic conditions inside the greenhouse during the bee activity time (BAT)-between 10:00 and 16:00 in mid-Februarywere a temperature of $30.4^{\circ}C$, relative humidity of 53.7%, illuminance level of 22,728.4lx, and UV level of $0.233mW/cm^2$. Bee traffic and foraging activity were at their greatest at 10:00 and tended to decrease with time. Male watermelon flowers typically dehisced between 10:00 and 12:00. Climatic conditions were significantly correlated with bee activities, including bee traffic and foraging activity. Bee activities were positively correlated with temperature, illuminance level, and UV level but negatively correlated with relative humidity. Temperature had the greatest effect on honeybee behavior. Among the foraging honeybees, the number of high-flying bees that did not pollinate flowers showed a strong positive correlation with temperature, and the number of bees landing on the flowers showed a positive correlation with the UV level. The temperature range inside greenhouses at which the pollination activities of honeybees can be maintained efficiently during winter watermelon pollination was found to be $21{\sim}25^{\circ}C$.

A Study of a Sunlight Collector System and Its Application (태양광 채광시스템의 조명 적용에 관한 연구)

  • 박준석;어익수;여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • In this paper, it is analysed the spectrum of optical fiber output through the sunlight collector system. As the result of the analysis, the sunlight collector system's UV distribution is lower then the sunlight'UV distribution. Also, the lighting environments under the optical fiber bundles are predicted when applied to the minimum workroom's(6${\times}$6${\times}$2.3[m]) interior lighting by using a lighting design program. In case of optical filer output\`s hight of 1.3[m], the illuminance value over 500[lx] in the area 50${\times}$50[cm] was achieved. As the result its feasibility as an interior lighting source shows no serious problem except the system cost.

  • PDF

DNN Model for Calculation of UV Index at The Location of User Using Solar Object Information and Sunlight Characteristics (태양객체 정보 및 태양광 특성을 이용하여 사용자 위치의 자외선 지수를 산출하는 DNN 모델)

  • Ga, Deog-hyun;Oh, Seung-Taek;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.29-35
    • /
    • 2022
  • UV rays have beneficial or harmful effects on the human body depending on the degree of exposure. An accurate UV information is required for proper exposure to UV rays per individual. The UV rays' information is provided by the Korea Meteorological Administration as one component of daily weather information in Korea. However, it does not provide an accurate UVI at the user's location based on the region's Ultraviolet index. Some operate measuring instrument to obtain an accurate UVI, but it would be costly and inconvenient. Studies which assumed the UVI through environmental factors such as solar radiation and amount of cloud have been introduced, but those studies also could not provide service to individual. Therefore, this paper proposes a deep learning model to calculate UVI using solar object information and sunlight characteristics to provide an accurate UVI at individual location. After selecting the factors, which were considered as highly correlated with UVI such as location and size and illuminance of sun and which were obtained through the analysis of sky images and solar characteristics data, a data set for DNN model was constructed. A DNN model that calculates the UVI was finally realized by entering the solar object information and sunlight characteristics extracted through Mask R-CNN. In consideration of the domestic UVI recommendation standards, it was possible to accurately calculate UVI within the range of MAE 0.26 compared to the standard equipment in the performance evaluation for days with UVI above and below 8.