• Title/Summary/Keyword: Ultrafiltration Membrane

Search Result 476, Processing Time 0.027 seconds

Enhancement of Ultrafiltration Performance Using Ultrasound (초음파를 이용한 한외여과의 성능 향상)

  • 염경호;육영재
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.283-290
    • /
    • 2003
  • To improve membrane performance, the dead-end and Cross-flow ultrafiltration with or without ultrasound irradiation onto the membrane module were carried out using a BSA protein solution. Intermittent or continuous irradiation of ultrasound effectively suppressed the formation of fouling on membrane or removed the fouling layers from membrane. Effect of ultrasound irradiation on the enhancement of ultrafiltration performance was more increased at the operating conditions which form more membrane fouling (at the operating conditions of higher feed concentration and TMP, and lower flow rate). The permeate flukes were enhanced up to 1.9 times in case of the dead-end ultrafiltration and 1.5 times in case of the cross-flow ultrafiltration by ultrasound irradiation onto the membrane module.

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

Separation of Humic Acid Using Polysulfone Ultrafiltration Membrane (폴리설폰 UF막에 의한 부식산 분리)

  • Song, Kun-Ho;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.343-350
    • /
    • 1999
  • The separation of humic acid by ultrafiltration was most influenced by pressure difference. when pressure difference increased from latm to 3atm, permeate flux increased from 40% to 60% but rejection rate reduced from 97% to 91% because of adsorption of molecules of humic acid at membrane surface. Since physical adsorption was more dominant than chemical adsorption, adsorption of membrane surface was reduced 50% when slow rate increased at same conditions.

  • PDF

History of Membrane Development and Mass Tranfer Modelling

  • Matsuura, Takeshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.33-89
    • /
    • 1996
  • History of Membrane Process Development 1920 : microfiltration : Zsigmondy 1930 : ultrafiltration 1950 : hemodialysis : Kolff 1955 : electrodialysis 1960 : reverse osmosis : Loeb, sourirajan 1960 : ultrafiltration 1979 : gas separation : Henis, Tripodi 1982 : pervaporation : Tusel

  • PDF

Modification of ultrafiltration membranes with carbon nanotube buckypaper for fouling alleviation

  • Guo, Jin;Liu, Jian-Hong;Wang, Li-Ying;Liu, Hong
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2015
  • The modification of ultrafiltration membranes with carbon nanotube (CNT) buckypaper on fouling control was investigated. Two types of commercially available flat-sheet membranes were used: PS35 and PES900C/D (PES) (the PS35 membranes were hydrophilic with a molecular weight cutoff of 20 kDa, and the PES membranes were hydrophobic with a molecular weight cutoff of 20 kDa). The CNT buckypaper modified ultrafiltration membranes were prepared by filtering a CNT suspension through the flat-sheet membrane in a dead-end ultrafiltration unit. After modification, the pure water flux of PES was significantly increased, while the pure water flux of PS35 was decreased. The properties of the CNT modified membranes were also investigated. Considering the antifouling properties, pure water flux of the modified membrane, and the stability of CNT buckypaper layer on the membrane surface, ethanol solution with a concentration of 50 wt.%, multi-walled carbon nanotubes (MWCNTs) with a larger diameter (30-50 nm), and the CNT loading with $7.5g/m^2$ was selected. The CNT buckypaper on the surface of ultrafiltration membranes can trap the pollutants in sewage effluent and prevent them reaching the surface of virgin membranes. Water quality analysis showed that the effluent quality of the modified membrane was obviously improved. The removal efficiency of humic acid and protein-like matters by the modified membrane was significant. These results indicate the potential application of the CNT buckypaper layer modified membranes in the field of wastewater reclaim.

Performance and characterization of PEG400 modified PVC ultrafiltration membrane

  • Aryanti, P.T.P.;Yustiana, R.;Purnama, R.E.D.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.6 no.5
    • /
    • pp.379-392
    • /
    • 2015
  • Polyvinyl chloride (PVC) ultrafiltration membrane was prepared by blending 12 wt.% of PVC in N, N-dimethylacetimide (DMAc) with polyethylene glycol 400 (PEG400) as an additive. The influence of PEG400 concentration on the PVC membrane morphology, permeability, fouling and rejection were investigated. Fouling and rejection of the PVC membrane were characterized by dextran T-100 filtration. The results showed that membrane water flux was increased up to $682Lm^{-2}h^{-1}$ when 28 wt.% of PEG400 was added into the PVC membrane solution. The best membrane performance with a low fouling and a high selectivity was achieved by adding 12 wt.% concentration of PEG400, which resulted in 90% rejection of dextran and 90% of flux recovery ratio. At further addition of PEG400 concentration, irreversible fouling was starting to increase. A 90% of irreversible fouling was formed in the PVC membrane when more than 22 wt.% of PEG400 is added.

Fouling characteristics of humic substances on tight polysulfone-based ultrafiltration membrane

  • Ariono, Danu;Aryanti, Putu T.P.;Wardani, Anita K.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.353-361
    • /
    • 2018
  • Fouling characteristics of humic substances on tight ultrafiltration (UF) membrane have been investigated. The tight UF membrane was prepared by blending polysulfone (PSf) in N.N-dimethylacetamide (DMAc) with 25%wt of Polyethylene glycol (PEG400) and 4%wt of acetone. Fouling characteristic of the modified PSf membrane was observed during peat water filtration in different trans-membrane pressure (TMP). It was found that the acetone modified membrane provided 13% increase in TMP during five hours of peat water filtration, where a stable flux was reached within 150 minutes. Meanwhile, the increase of TMP from 10 psig to 30 psig resulted in a fouling resistance enhancement of 60%. Furthermore, based on the fouling analysis, fouling mechanism at the first phase of filtration was attributed to intermediate blocking while the second phase was cake formation.

Synthesis and Characterization of Copoly(amide-imide) Derivatives and Ultrafiltration Membrane Performances II - Permeation Properties of Copoly(amide-imide)s Ultrafiltration Membranes -

  • Jeon, Jong- young;Kim, Jong-hp
    • Korean Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.24-31
    • /
    • 2001
  • Ultrafiltration membranes base on copoly(amide-imide) derivatives were prepared by the phase inversion method and the factors determining the permeation characteristics of membrane were investigated. The permeation behavior was observed by the relative ratio of permeate flux (J$\_$t/)/pure water flux (J$\_$o/). The characteristics through membrane were measured using aqueous solution of poly(ethyleneglycol) (MW 2.0$\times$10$\^$4/) over a temperature range of 10∼90$\^{C}$. With increasing the operating temperature, the relative ratio of flux became high. All the membranes had good chemical stability. Copoly(amide-imide) membranes having various Permeation properties could be obtained. Further, it was proved that the membrane performances could be determined from the preparation conditions as well as various operating conditions.

  • PDF

The Major Developments of the Evolving Reverse Osmosis Membranes and Ultrafiltration Membranes

  • Kurihara, Masaru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.9-16
    • /
    • 1991
  • The current status of reverse osmosis and ultrafiltration membranes are reviewed with the view for the future. In the case of reverse osmosis (RO) membranes, as examples, new crosslinked aromatic polyamide membranes exhibited the superior separation performance with the sufficient water permeability, the high tolerance for oxidizing agents and chemicals. Ultrafiltration (UF) membrane based on poly(phenylene sulfide sulfone) (PPSS) also exibited the superior separation performance with the high solvent, heat and fouling resistance.

  • PDF

Membrane Ultrafiltration for Apparent Molecular Weight Distributions of Dissolved Organic Matter

  • Seo, Jun-Won;Sa, Tongmin;Kim, Jong-Soo
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • Apparent MWDs of DOM in natural waters and swine wastewaters were determined through membrane ultrafiltration. The nominal MWCOs of ultrafiltration membranes by the manufacturer were confirmed to be similar with those obtained from the ultrafiltration procedures employed in this study using six MW standard compounds. Natural waters showed a wide range of MWOs, but 62.4~87.5% were in the range of MW<10K. High MW fractions were preferentially removed through water treatment processes. Swine wastewater showed two major ranges of MWDs, 49.0% in <1K and 36% in >50k while anaerobically treated swine wastewaters showed 17.5~18.0% in <1K and 53.0~58.8% in <50K. The overall DOM was reduced during anaerobic treatment by 76.8~80.0% as COD; however. the percentage of low MW fractions decreased and that of the high MW fractions increased.

  • PDF