• 제목/요약/키워드: Ultrasonic C-scanner

검색결과 23건 처리시간 0.03초

초음파 주사장치의 Computer화 (Computerization of Ultrasonic Scanner)

  • 김영환;김영길;이세경
    • 비파괴검사학회지
    • /
    • 제4권2호
    • /
    • pp.15-19
    • /
    • 1985
  • Computerization of ultrasonic scanner is considered to achieve more quantitative and reliable ultrasonic testing. Testech LS-24 ultrasonic scanner is modified, and step motors in this modified ultrasonic scanner are driven by multiprogrammer controlled by computer. Two step motors can be controlled independently and simultaniously. The performance of computerized ultrasonic scanner is examined entloying modified C scan for a flat bottom hole ultrasonic reference block.

  • PDF

초음파를 이용한 용접부 핸디 스캔 검사기 개발 (Developement of Ultrasonic Handy Scanner for Welding Inspection)

  • 강동명
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.14-18
    • /
    • 2005
  • The ultrasonic handy scanner to be developed in this research is a nondestructive inspection equipment with various facility. The ultrasonic inspection is the technique area which apply range is increasing greatly with IT. The purpose of this research is development of a ultrasonic handy scan inspection device with the utility in a work spot. The ultrasonic handy scanner to be developed with portability in this research is able to carry out the spot inspection. It can contribute to the quality improvement, cost reduction and safety design.

컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구 (A study on Computer-controlled Ultrasonic Scanning Device)

  • 허형;박치승;홍순신;박종현
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발 (Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor)

  • 주영상;배진호;박창규;이재한;김종범
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.338-344
    • /
    • 2010
  • 웨이브가이드 초음파센서를 적용하여 소듐냉각 고속로 KALIMER-600의 원자로 노심과 내부구조물의 소듐내부가시화를 수행하는 이중회전 구동 C-스캔 시스템과 소프트웨어 프로그램 Under-Sodium MultiVIEW를 개발하였다. 이중회전 구동 C-스캔 시스템은 KALIMER-600 원자로 헤드의 이중회전 플러그를 모사하여 설계 제작하였으며 웨이브가이드 초음파센서에 초음파 펄스를 송수신할 수 있는 고출력 초음파 시스템과 스캐너 구동 제어 장치를 구축하였다. Under-Sodium MultiVIEW 프로그램은 이중회전 스캐너의 구동을 제어하면서 웨이브가이드 초음파센서에 초음파 신호를 송수신하여 영상 처리를 수행하는 소듐내부가시화 프로그램으로서 LabVIEW 그래픽 프로그램 언어를 기반으로 개발되었다. 이중회전 구동에 의한 수중 C-스캔 성능시험을 수행하여 Under-Sodium MultiVIEW 프로그램의 가시화 성능을 실험적으로 검증하였다.

탄소섬유복합평판에 낙추충격을 가할 때 적층구성에 미치는 영향에 관한 연구 (A Study on the Influence of Stacking Sequences using CFRP Laminate Plates by Falling Weight Impact)

  • 임광희;박노식;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.106-109
    • /
    • 2000
  • Impact tester was build up to evaluate the characterization of CFRP laminate plates under the low velocity impact. The tests were conducted on several laminates of different ply orientation A system was budded for the impact strength of CFRP laminates in consideration of stress wave propagation theory using drop-weight impact tester as one of impact test. Results indicate that absorbed energy of quasi-isotropic specimen having four interfaces is higher than that of orthotropic laminates with two interfaces. Also the damage area was measured with ultrasonic C-scanner on some samples. In the specimens the relationship was linear between damaged area and absorbed energy to some degree. Absorbed energy in the specimen that ply number, interface number and fiber stacking sequences is same but having hybrid is higher than that of orthotropic laminates without hybrid.

  • PDF

DSP 를 이용한 초음파 C-scan 시스템 개발 (Ultrasonic C-scan System Development Using DSP)

  • 남영현;성운학;김정태
    • 한국정밀공학회지
    • /
    • 제16권7호
    • /
    • pp.32-39
    • /
    • 1999
  • Digital signal processor (DSP) is used to obtain the peak value and the time difference of ultrasonic signals, to make digital filter, and to derive mathematical transformation from analog circuit. In this study, C-scan system and control program have been developed to high speed data acquisition. This system consists of signal processing parts (DSP, oscilloscope, pulser/receiver, digitizer), scanner, and control program. The developed system has been applied to a practical ultrasonic testing in overlay weld, and demonstrated high speed with precision

  • PDF

A STUDY ON IMPACT CHARACTERISTICS OF THE STACKING SEQUENCES IN CFRP COMPOSITES SUBJECTED TO FALLING-WEIGHT IMPACT LOADING

  • Im, K.H.;Park, N.S.;Kim, Y.N.;Yang, I.Y.
    • International Journal of Automotive Technology
    • /
    • 제4권4호
    • /
    • pp.203-211
    • /
    • 2003
  • This paper describes a method for a falling weight impact test to estimate the impact energy absorbing characteristics and impact strength of CFRP (Carbon-fiber reinforced plastics) laminate plates based on considerations of stress wave propagation theory, which were converted to measurements of load and displacement verses time. The delamination area of impacted specimens for the different ply orientations was measured with an ultrasonic C-scanner to determine the correlation between impact energy and delamination area. The energy absorbed by a quasi-isotropic specimen having four interfaces was higher than that of orthotropic laminates with two interfaces. The more interfaces, the greater the energy absorbed. The absorbed energy of a hybrid specimen embedding GFRP (Glass-fiber reinforced plastics) layer was higher than that of normal specimens. Also, a falling weight impact tester was built to evaluate the characteristics and impact strength of CFRPs.

초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과 (Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images)

  • 양정화;강관석;이경성;팽동국;최민주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.277-283
    • /
    • 2009
  • 임상에서 정확한 진단을 위해 양질의 초음파 영상을 얻는 것은 중요하다. 본 연구에서는 초음파 진단기의 주파수와 동적 영역(dynamic range, DR) 설정 및 프로브 유형에 따른 초음파 영상의 변화를 관찰하였다. 실험에서 고형 및 낭성 종괴 병변과 유사한 초음파 평가 팬텀(539,551, ATS, USA)의 6가지 LCS(low contrast sensitivity) 표적(-15, -6, -3, +3, +6, +15 dB)에 대한 영상을 대상으로 평가하였다. 초음파 영상은 볼록형(convex, C3-7IM) 및 선형(linear probe, L5-12IM) 두 가지 탐촉자(Probe)에 대해 SA-9900(Medison Ltd, Korea)을 이용하여 얻었다. 주파수는 4가지 방식(gen, pen, res, harmonic), 동적영역은 $40{\sim}100\;dB$ 범위에서 설정을 변화하면서 영상을 취득하였다. 취득한 영상의 질은 표적의 명목상 LCS 값과 영상에서 측정된 LCS을 비교하여 평가 하였다. 실험 결과 볼록형 탐촉자의 경우, 각 LCS 표적에 대해 주파수 방식 별로 동적영역 값을 40, 60, 80, 100 dB로 변화할 때, 초음파 영상의 질은 유의한 변화가 없었다. 그러나 낭종성 병변에 가까운 LCS 표적 -15 dB에서는 동적영역 60 dB과 하모닉 주파수 방식에서 LCS 값이 높게 나타났다. 선형 프로브에서는 -15 dB LCS 표적에서 동적영역 40 dB, 하모닉 방식에서 명목상 값에 근접하였다. LCS관점에서 정량화된 영상의 평가의 한계와 주관적인 평가 즉 심리적인 관점에서의 ROC(Receiver Operating Characteristic) 평가의 필요성에 대해 토의하였다.

  • PDF

초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과 (Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images)

  • 양정화;이경성;강관석;팽동국;최민주
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 초음파 진단기의 설정은 영상의 질에 영향을 준다. sonographer는 최적의 영상을 얻기 위해 초음파 영상의 질에 영향을 주는 설정 변수에 대한 효과를 이해해야 한다. 본 연구에서는 4가지 대표적인 영상 조절 변수 즉 TGC (Time Gain Control), 이득 (Gain), 주파수 (Frequency), DR (Dynamic Range)를 고려하였다. 초음파 영상의 질은 LCS (Law Contrast Sensitivity) 관점에서 정량적으로 비친 평가하였다. 실험은 임상용 초음파 진단기 (SA-9000 PRIME, Medison, Korea)를 사용하여 초음파 평가 팬텀 (539, ATS, USA)의 LCS 타겟을 영상화하였다. 영상 조절 변수의 설정을 변화하면서, 각 설정에 대한, 6개의 LCS 영상 (+15 dB, +C dB, +3 dB, -3 dB, -6 dB, -15 dB)을 취득하고, 영상에 대한 LCS픽셀 값을 계산하였다. 실험결과 TGC가 최대, Gain은 중간에서 최대사이, 주파수가 Pen모드, DR이 40-66 dB일 때 타겟 영상 (LCS)의 평균 픽셀 값이 높았다. 모든 타겟 영상에서 DR이 40 dB일 때에 LCS가 좋은 영상을 얻었다. 본 결과는 임상에서 잘 발견되는 solid lesion (+15, +6, +3 dB 타겟과 유사) 또는 cystic lesion (-15, -6, -3 dB 타겟과 비슷)이 있는 mass 평가 시 적절한 영상조절 변수 설정에 유용한 정보를 제공할 것으로 기대된다.

Ultrasonic Approach of Rayleigh Pitch-catch Contact Ultrasound Waves on CFRP Laminated Composites

  • Yang, In-Young;Im, Kwang-Hee;Heo, Uk;Hsu, David K.;Sim, Jae-Ki;Kim, Hak-Joon;Song, Sung-Jin
    • 한국주조공학회지
    • /
    • 제27권5호
    • /
    • pp.209-211
    • /
    • 2007
  • 최근에는 탄소섬유강화복합재료(CFRP)는 우수한 기계적인 물성치와 수월한 설계특성으로 인해 우주.민간 항공산업분야 뿐만 아니라 여러분야에 응용성이 매우 높다. 그러나 CFRP 복합적층판으로 제작된 구조물은 충격손상을 받을 시에는 50-75%치 강도가 낮아지는 취약성을 가지고 있다. 따라서 본 연구에는 CFRP복합재의 구조건전성 및 결함여부를 비파괴적으로 검사 및 탐상을 하기 위해서 시도하였다. 특히, C-scanner의 수침조에서 충격손상을 받은 시험편을 집어넣어 자동 데이터 획득 시스템을 구동하여 현장응용성이 가장 높은 일 방향 초음파측정 (one-sided ultrasonic measurement) 방법인 평가기법을 제안하였다. 본 연구에서 제안한 일방향 초음파 피치캐치방법이 CFRP 복합적층판내에서 일반 수직 초음파 탐상기법보다 훨씬 민감함을 알 수 있었다.