• 제목/요약/키워드: Ultrasonic Flowmeter

검색결과 40건 처리시간 0.021초

전달 시간차 방식 다회선 초음파 가스 유량계 개발 (Study on the Development of Multi-Path Ultrasonic Gas Flowmeter)

  • 황원호;박상국;이치환;장경영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

초음파 가스 유량계 개발과 활용 (Development and Application of an Ultrasonic Gas Flowmeter)

  • 황원호;박상국;정희돈;장경영
    • 비파괴검사학회지
    • /
    • 제22권3호
    • /
    • pp.246-253
    • /
    • 2002
  • 제철공정에서 발생하는 열악한 환경의 가스를 계측하기 위해서 개발한 초음파 가스 유량계와 현장 적용 결과에 대해서 기술한다. 개발된 초음파 유량계는 제철공정에 생산되는 부생가스인 LDG, COG, BFG 등의 활용에 적합하도록 개발했다. 그리고 본 초음파 유량계는 초음파 전달시간차 방식을 채택하고 있다. 전달 시간차 방식의 초음파 유량계를 구현하기 위한 초음파 신호의 송수신 알고리즘 및 초음파 신호처리 알고리즘을 개발했다. 유량계의 성능을 검증하기 위해서 대용량 유량 검 교정 장치를 자체 제작하여 유량계 검 교정 실험을 행했고 Venturi Type의 기준유량계와 비교실험을 통해서 측정오차를 평가했다. 실제 제철공정에 1년 이상의 적용 테스터를 통해 초음파 유량계의 신뢰성을 확인했으며 현재 상업화 모델이 개발되어 현장에서 활용 중에 있다.

배관 형상이 다회선 초음파 유량계의 특성에 미치는 영향 (Installation effects on the characteristics of multi-path ultrasonic flowmeter)

  • 박경암;최용문;최해만;윤병로;황규보
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.114-117
    • /
    • 1999
  • Five-path ultrasonic flowmeters (200 and 300 mm diameters) were tested to obtain it's characteristics in a water flow standard system. A five-path ultrasonic flowmeter was installed after various pipe fittings (elbow, valve, tee) or a pump. The distance between flow disturbance source and a flowmeter was main experimental parameter. Without a flow conditioner, a five-path ultrasonic flowmeter shows good characteristics as the distance between flow disturbance source and a flowmeter is longer than 10 diameter of a flowmeter.

  • PDF

초음파 가스 유량계 개발 연구 (Study on the development of ultrasonic gas flowmeter)

  • 황원호;박상국;양규홍;장경영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.76-81
    • /
    • 2001
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has already well been proven by extensive field tests for several months in POSCO, iron & steel making company.

  • PDF

유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구 (A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters)

  • 이동근;박종호
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

초음파 가스 유량계 개발 연구 (Study on the Development of Ultrasonic Gas Flowmeter)

  • 황원호;박상국;장경영
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.138-143
    • /
    • 2003
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG. COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has been proven by extensive field tests for several months in POSCO, iron & steel making company.

밸브후단에서의 다회선 초음파 유량계의 특성변화 (Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter with Valve)

  • 황상윤;서경호;김병찬;김경식;장학수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.65-74
    • /
    • 2000
  • A five path ultrasonic and/or magnetic flowmeter were installed after valve. Five path ultrasonic flowmeter were tested to obtain it's performance in a water flow standard system and magnetic flowmeter. It's varied with straight pipe length(nD), install direction and valve position. All the results are summerized. The multi-path flowmeters(MUF) showed up to $\pm0.5{\%}$ at a 2, 4, 8, 15D spacing : the MUF was significantly better than magnetic flowmeter at disturbed flow conditions.

  • PDF

원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구 (A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants)

  • 유성식;박종호
    • 한국유체기계학회 논문집
    • /
    • 제6권1호
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

기체유량계용 초음파 센서의 설계 및 공진 특성 (Design and Resonant Characteristics of the Ultrasonic Sensor for Gas Flowmeter)

  • 홍재일;이상철
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.193-197
    • /
    • 2002
  • In this paper, the ultrasonic sensor for gas flowmeter was simulated, fabricated and measured according to the assembly step and the piezoelectric vibrator layers. The simulated resonant frequency and the measured resonant frequency were similar except two layer sensor. The simulated resonant frequency of three layer sensor was 48 kHz and the measured resonant frequency of three layer sensor was 45.2 kHz. From the results, the ultrasonic sensor for gas flowmeter could be designed and expected without fabrication.

다회선 초음파 유량계를 이용한 거래용 오일유량 측정 (Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement)

  • 황상윤;이호준;박기환
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF