• Title/Summary/Keyword: Ultrasonics

Search Result 130, Processing Time 0.025 seconds

A Study on the Intensity Measurng of Ultrasonics by Added Two Sensive point of Thermocouple (이감온점 열전대에 의한 초음파의 강도측정에 관한 연구)

  • Kim, Ju-Hong;Lee, Dong-Hwi;O, Yeong-Don
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.6
    • /
    • pp.1-7
    • /
    • 1971
  • This paper describes concerning the method of measurement for the intensity of ultrasonics in liquid. The probe which is added two sensive point of thermocople which is surrounded by the absorbed material of sonic wave on the both side of the refleftite plate have measured the intensity of ultrasonics indirectly by the difference of the temperature of two sensive point which had raised the temperature by the sonic wave and its reflective wave which transmitted the ultrasonic energy. This minify the influence from the temparature of liquid and time constant. Consequently, this is the basic industrial method which is with in the bounds of possibility on the simple measurement of the intensity of the local ultrasonics concerning direction of its propagation.

  • PDF

Finite element modeling of laser ultrasonics nondestructive evaluation technique in ablation regime

  • Salman Shamsaei;Farhang Honarvar
    • Advances in Computational Design
    • /
    • v.8 no.3
    • /
    • pp.219-236
    • /
    • 2023
  • In this paper, finite element modeling of the laser ultrasonics (LU) process in ablation regime is of interest. The momentum resulting from the removal of material from the specimen surface by the laser beam radiation in ablation regime is modeled as a pressure pulse. To model this pressure pulse, two equations are required: one for the spatial distribution and one for the temporal distribution of the pulse. Previous researchers have proposed various equations for the spatial and temporal distributions of the pressure pulse in different laser applications. All available equations are examined and the best combination of the temporal and spatial distributions of the pressure pulse that provides the most accurate results is identified. This combination of temporal and spatial distributions has never been used for modeling laser ultrasonics before. Then by using this new model, the effects of variations in pulse duration and laser spot radius on the shape, amplitude, and frequency spectrum of ultrasonic waves are studied. Furthermore, the LU in thermoelastic regime is simulated by this model and compared with LU in ablation regime. The interaction of ultrasonic waves with a defect is also investigated in the LU process in ablation regime. Good agreement of the results obtained from the new finite element model and available experimental data confirms the accuracy of the proposed model.

The Use of Guided Waves for Rapid Screening of Chemical Plant Pipework

  • Alleyne, D.N.;Pavlakovic, B.;Lowe, M.J.S.;Cawley, P.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.589-598
    • /
    • 2002
  • The safe operation of petrochemical plant requires screening of the pipework to ensure that there are no unacceptable levels of corrosion. Unfortunately, each plant has many thousands of metres of pipe, much of which is insulated or inaccessible. Conventional methods such as visual inspection and ultrasonic thickness gauging require access to each point of the pipe which is time consuming and very expensive to achieve. Extensional or torsional ultrasonic guided waves in the pipe wall provide an attractive solution to this problem because they can be excited at one location on the pipe and will propagate many metres along the pipe, returning echoes indicating the presence of corrosion or other pipe features. Guided Ultrasonics Ltd have now commercialised the technique and this paper describes the basis of the method, together with examples of practical test results and typical application areas.

Implement Of Automobile Robot Using the Ultrasonic Sensors And the DSP Chip(TMS320C31) (초음파 센서와 DSP 음성인식을 이용한 이동 로봇 구현)

  • 임창환;문철홍
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.155-158
    • /
    • 2000
  • In this paper, For operator's conveniency of the mobile robot, achieved the system which control the robot by adopting the speaker independently isolated word recognition and by implementing the real time with TMS320C31. and This paper using the Tri-ultrasonics range finder to detect obstacles and implements the mobile robot. In this paper, DSP processor (TMS320C31) is used signal processing for speech recognition in the real time and Micro processor(80C196KC) is controling the ultrasonics range finders.

  • PDF

CLEANLINESS AND WALL MOPHOLOGY OF ULTRASONIC ROOT-END RETROGRADE CAVITY (초음파로 형성된 치근단 역충전와동의 정화도 및 와벽형태)

  • Kim, Sung-Kyo;Lee, Jae-Whan;Baek, Seung-Moo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.536-545
    • /
    • 1997
  • The purposes of this study were to evaluate the degree of cavity cleanliness and to observe cavity wall morphology when root-end retrograde cavity preparation was done with ultrasonics. Root resections were done on 20 extracted human maxillary central incisors after canal filling with gutta-percha, and retrocavities were prepared using a slow-speed round bur as a control, and stainless steel ultrasonic tips of power settings of 2 and 6 ($Miniendo^{TM}$, EIE, SA, USA) as experimentals. The degree of the remaining cavity debris and smear layer, and wall morphology were evaluated under the scanning electron microscope. The results were as follows : Cavity prepared with ultrasonics of either power setting showed significantly less smear layer than did slow-speed preparations (p<0.01). However, there was no significant difference in canal debris (p<0.05). Cavity prepared with ultrasonics showed hatcheted appearance of wall, while slow-speed preparation showed relatively plain one.

  • PDF

Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 이상훈;심승환;이광식;김달우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • It is well known that a partial-discharge(PD) in insulation oil is the source of various physical and chemical phenomena, such as heat, light, gas, chemical transformation, electric current, electromagnetic radiation and ultrasonics. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Ultrasonic-wave detection is a useful method for the diagnosis of the transformer-insulation condition. Conventionally, ulyrasonic waves are detected by Piezo-electric transducer, but we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

EFFICIENCY OF ULTRASONIC ROOT-END RETROGRADE CAVITY PREPARATION AND ITS INFLUENCE ON TOOTH STRUCTURE (초음파기구의 치근단 역충전와동형성 효율 및 치질에의 영향)

  • Lee, Jae-Whan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.546-559
    • /
    • 1997
  • The purposes of this study were to evaluate the efficiency of cavity preparation and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with ultrasonics. 91 distobuccal root-ends of extracted human maxillary first molars were cut by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw, retrocavities were prepared using a slow-speed no. 2 round bur as controls, and stainless steel ultrasonic tips of power settings of 1 through 10 as experimentals. Time consumed and the number of strokes used for the cavity preparation were measured and evaluated, and the incidence of tooth cracks was observed under a stereomicroscope. The results were as follows : For the retrograde cavity preparation, time and number of strokes used were decreased as the ultrasonic power setting increased (p<0.001). High power setting of ultrasonics induced significantly more tooth cracks than did the slow-speed bur or low- and medium power setting of ultrasonics (p<0.05). Teeth with previous crack induced significantly more tooth cracks than those without previous one when high power setting of ultrasonics were used for the retrograde cavity preparation (p<0.001). Teeth with initial apical canal size of no. 10 induced significantly more crack than did those with size of no. 15 when low power setting of ultrasonics were used for the retrograde cavity preparation (p<0.05).

  • PDF

A Study on Evaluation of Thermal Shock Damage of Metal Matrix Composite using Ultrasonics (초음파를 이용한 금속복합재료의 열충격 손상 평가 연구)

  • 강문필;이준현
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.31-37
    • /
    • 2000
  • Metal matrix composites(MMCs) are rapidly becoming one of the strongest candidates for structural materials for many high temperature application. Among the high temperature environment, thermal shock is known to cause significant degradation in most MMC system. Therefore, the nondestructive evaluation on thermal shock damage behavior of SiC/A16061 composite has been carried out using ultrasonic surface and SH-waves. For this study, Sic fiber reinforced metal matrix composite specimens fabricated by a squeeze casting technique were thermally cycled in the temperature range 25~$400^{\circ}C$ up to 1000 cycles. Three point bend test was conducted to investigate the effect of thermal shock damage on mechanical properties. The relationship between thermal shock damage behavior and the change of ultrasonic velocity and attenuation were discussed by considering SEM observation of fracture surface.

  • PDF