• 제목/요약/키워드: Ultrasound diagnostic system

검색결과 61건 처리시간 0.023초

초음파 영상진단장치 (A Diagnostic Ultrasound Imaging System)

  • 이승우
    • 비파괴검사학회지
    • /
    • 제19권3호
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

초음파검사실 감염관리 인식에 대한 연구 (A Study on the Perception of Infection Control in Ultrasound Diagnostic Room)

  • 안현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.367-374
    • /
    • 2020
  • The purpose of this study is to understand the infection prevention system and infection management perception of Ultrasound diagnostic room in medical institutions by sonographer's in general practitioner, semi and general hospitals. As a research method, a statistical analysis was conducted by surveying a total of 20 items in four category to determine the infection perception of sonographer's according to gender, age, working institution, and working period. As a result of infection awareness, males were in the ultrasound gel management category, women were in the transducer management category, all age groups were in the transducer management system category, and the General Practitioner, semi and general hospitals. were in the transducer management system category, and general hospitals showed a high degree of infection awareness in the category of disinfection and sterilization, and in the category of transducer management in the entire working period. In the results of the analysis of the correlation between the sub-factors of the perception of infection control in the Ultrasound diagnostic room the degree of correlation between each category showed a middle degree correlation(r>0.5) and a significant difference by category(p<.01). In conclusion, the prevention of infection in the ultrasound diagnostic room, which sonographer's firms think, was found to be the most efficient ultrasound diagnostic room infection control to implement transducer and gel management in accordance with the principles of disinfection and sterilization.

초음파진단기의 Beam Simulation (Beam Simulation in Diagnostic Ultrasound)

  • 배무호;이승우
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.289-292
    • /
    • 1996
  • The 2-way beam simulation for the diagnostic ultrasound is performed with simplified computation by approximating the transducer and the system. The results show that the simulation program can be used as a good system design tool.

  • PDF

근골격계 초음파검사가 도움이 되는 진료 상황 (Clinical Situations in which Musculoskeletal Ultrasound is Helpful)

  • 조길호
    • Journal of Yeungnam Medical Science
    • /
    • 제18권2호
    • /
    • pp.170-186
    • /
    • 2001
  • Musculoskeletal ultrasound (MSUS) has newly evolved by the mechanical improvement of the machine over past several years, becoming a part of imaging techniques for the evaluation of variable diseases in the musculoskeletal system. MSUS has proven diagnostic superiority in pathologies including rotator cuff disease of the shoulder, lateral epicondylitis of the elbow, diseases of the peripheral nerve, detection of intra-articular loose bodies and soft tissue foreign bodies, and in evaluating small superficial soft tissue tumors such as ganglion, epidermoid cyst, and glomus tumor. Besides, MSUS is very useful for obtaining tissue or fluid via percutaneous fine needle aspiration and/or biopsy for the histopathologic diagnosis. Combining MSUS with MR would play a great role in the field of the diagnostic imaging of the musculoskeletal system. The MSUS examiner should have the knowledge of cross-sectional anatomy, and of the mechanical and physical properties of ultrasound in order to interpret the ultrasound findings accurately and properly, and to avoid diagnostic errors due to variable artifacts subsequently. The goal of this article is to introduce the capabilities of MSUS in certain kinds of clinical situation and to familiarize the reader with MSUS. For the purpose, author intends to describe this article according not to the disease-, or organ-based, but to the clinical problem-based format.

  • PDF

전국 소동물 병원의 초음파 진단기기 및 활용도 현황조사 (Survey on Utilization of Ultrasonographic Machine in Small Animal Clinics in South Korea)

  • 장진화;백민지;장동우
    • 한국임상수의학회지
    • /
    • 제28권4호
    • /
    • pp.408-414
    • /
    • 2011
  • This study was carried out to analyze the utilization of ultrasound machines in animal hospitals and focused on surveying the present condition of diagnostic ultrasound on veterinary medicine in South Korea. Total 279 veterinary hospitals were surveyed with e-mail questionnaires or telephone survey. E-mail questionnaires consist of 17 items of questions including existence of ultrasound machine, types of ultrasound machine, ultrasound examination costs, frequency, purposes, other diagnostic imaging equipments, and referring system of ultrasound. Telephone surveys asked about the existence of the ultrasound machine and types of the ultrasound machine to 279 animal hospitals. Two hundred and seventy-one out of 279 animal hospitals holds ultrasound machine. Seventy-two percents clinics purchased used ultrasonographic machines and mean years after the date of manufacture is 7.5 years and the proportion of superannuated machines are relatively high. Also many clinicians prefer single organ scanning rather than general scan technique and more than 60% of clinics perform ultrasonographic examination less than 5 times a week. Clinics located in Seoul area tend to have more expensive and brand-new ultrasonographic machines and the distribution of radiology specialist are higher in this area. Problems associated with the present condition were oversupply of machines, unequal distribution of the medical equipment in different localities, ineffective use of the medical equipment, and high percentage of old poor-quality medical equipments. There should be a viable alternative proposal to control amount and quality of the ultrasound machines. Also, the improved management system for the ultrasound machine is required.

초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계 (Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics)

  • 임도형;김은근;이균정;박원필;김한성;신태민;최서형;이용흠
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.

수십 MHz 대역 초음파 트랜스듀서와 그 응용 (Ultrasound Transducers in Several Tens MHz Band and Their Applications)

  • 하강렬;김무준
    • 한국음향학회지
    • /
    • 제22권8호
    • /
    • pp.622-628
    • /
    • 2003
  • 최근 안과 또는 피부과의 의료진단분야에 도입하기 위한 수십 μm 이하의 높은 공간분해능을 갖는 수십 MHz 대역의 초음파 트랜스듀서에 대한 연구가 활발히 수행되고 있다. 본 해설에서는 그 연구의 배경 및 트랜스듀서의 구조와 특성, 그리고 그것을 이용하여 얻은 영상에 대하여 간략하게 소개하였다.

Artificial Intelligence-Based Breast Nodule Segmentation Using Multi-Scale Images and Convolutional Network

  • Quoc Tuan Hoang;Xuan Hien Pham;Anh Vu Le;Trung Thanh Bui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권3호
    • /
    • pp.678-700
    • /
    • 2023
  • Diagnosing breast diseases using ultrasound (US) images remains challenging because it is time-consuming and requires expert radiologist knowledge. As a result, the diagnostic performance is significantly biased. To assist radiologists in this process, computer-aided diagnosis (CAD) systems have been developed and used in practice. This type of system is used not only to assist radiologists in examining breast ultrasound images (BUS) but also to ensure the effectiveness of the diagnostic process. In this study, we propose a new approach for breast lesion localization and segmentation using a multi-scale pyramid of the ultrasound image of a breast organ and a convolutional semantic segmentation network. Unlike previous studies that used only a deep detection/segmentation neural network on a single breast ultrasound image, we propose to use multiple images generated from an input image at different scales for the localization and segmentation process. By combining the localization/segmentation results obtained from the input image at different scales, the system performance was enhanced compared with that of the previous studies. The experimental results with two public datasets confirmed the effectiveness of the proposed approach by producing superior localization/segmentation results compared with those obtained in previous studies.

유한차분법을 이용한 기능성 위장 장애 진단용 초음파 시스템의 개발 (Development of Ultrasound Diagnostic System for Functional Gastrointestinal Disorders using Finite Difference Method)

  • 박원필;우대곤;고창용;이균정;이용흠;최서형;신태민;김한성;임도형
    • 한국정밀공학회지
    • /
    • 제24권9호
    • /
    • pp.130-139
    • /
    • 2007
  • The disaster from functional gastrointestinal disorders (FGID) has detrimental impact on the quality of life of the affected population. There are, however, rare diagnostic methods for FGID. Our research group identified recently that the gastrointestinal tract well of the patients with FGID became more rigid than that of healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The objective of the current study is, therefore, to identify feasibility of a diagnostic system for FGID based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid models) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. Based on the results from FD analysis, the ultrasound system for diagnosis of the FGID was developed and clinically tested via application of it to 40 human subjects with/without FGID who were assigned to Normal and Patient Groups. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasound reflective signal in the rigid models $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal model $(0.1{\pm}0.0Vp-p)$. Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasound reflective signals near to the gastrointestinal tract well for the patient group $(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group $(0.1{\pm}0.2Vp-p)$. These findings suggest that our customized ultrasound system using the ultrasound reflective signal may be helpful to the diagnosis of the FGID.

A Review of the Clinical Use of Ultrasound in Korean Traditional Medicine

  • Kim, Seok Hee;Yook, Tae Han;Song, Beom Yong;Choi, Yoo Min;Shin, Jin Hyeon;Shin, Hye Jeong;Lee, Sanghun;Jeon, Young Ju;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • 제36권4호
    • /
    • pp.204-210
    • /
    • 2019
  • This study was performed to evaluate research studies utilizing ultrasound diagnostic units, the practitioners who performed the ultrasound assessments, and how they had been used primarily in tandem with the Korean Medicine Advanced Searching Integrated System. This study identified 46 studies following a literature search, and discovered that a Korean medicine doctor led the ultrasonography in 13 studies, a medical technician was responsible in 6 studies, a roentgenologist carried it out in 5, and 19 of the studies did not specify who had conducted it. Ultrasonography had been actively used in the course of the clinical practice of Korean medicine, and it may serve as a useful and reliable diagnostic tool for evaluating the effectiveness of Korean medicine. The results of this study will help to promote more ultrasound studies in the future.