• Title/Summary/Keyword: Unbalance Weight

Search Result 62, Processing Time 0.026 seconds

Study on the replacement of last moving blade at lower pressure turbine (저압 터빈 마지막 단 동익 교체에 대한 고찰)

  • Koo, Jae-Raeyang;Lee, Woo-Kwang;Koo, Woo-Sik;Kim, Yeon-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.834-838
    • /
    • 2003
  • Vibration of turbine is concerned with array of last moving blade at lower pressure turbine. When last moving blade at lower pressure turbine was replaced, we must consider mass unbalance problems of blades. If mass unbalance happened at rotor, it is impossible to operate turbine. In this paper, we have how to minimize the mass unbalance problems of last moving blade at lower pressure turbine.

  • PDF

Physique, Physical Fitness, Body Composition and Blood Lipid by BMI of Female Students in a Teachers' College (여자 교대생들의 BMI에 따른 체격, 체력, 체조성 및 혈중지질 비교)

  • Kim, Do-Yeon;Kim, Jong-Won
    • Journal of health informatics and statistics
    • /
    • v.42 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • Objectives: The purpose of this study was to provide the basic materials to form sense of value for health and to emphasize the importance of physical education by comparative analysis of physique, physical fitness, body composition and blood. Methods: The subjects were 188 female college students and they were classified 3 groups by BMI: lower weight group (LWG), normal weight group (NWG), and over weight group (OWG). Results: In the physique, there was significantly high in order LWGNWG, OWG in unbalance of the upper and lower parts of the body, and LWG, OWGNWG, OWG in HDL-C. Conclusions: In the result of this study, it is recognized that regular exercise as well as eating right, life style are needed and offered to take part in the exercise programs for healthy campus life of female college students.

Diagnosis of Edge overcoating by Air Knife Pattern Modification in CGL (용융아연도금라인에서 에어나이프 형상패턴 변경에 의한 단부과도금 진단)

  • 배용환;최홍태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.20-28
    • /
    • 2000
  • Air wiping technique is widely used because of easy and efficient coating control in present CGL The coating weight is controlled by nozzle header pressure. strip line speed, and the distance between strip and nozzle. Coating defects are resulted from the unbalance of these control factors and the inaccuracy of coating equipments. We investigates the main cause of coating defects, such as edge overcoating and coating deviation through various experiments. It is found that the edge overcoating is mainly come from nozzle lip type, and the coating deviation is caused by the unbalance of dynamic pressure.

  • PDF

Analysis of Magneto-rheological Fluid Based Semi-active Squeeze Film Damper and its Application to Unbalance Response Control of Rotor (자기유변유체를 이용한 반능동형 스퀴즈 필름 댐퍼의 해석 및 회전체 불균형 응답 제어)

  • Kim, Keun-Joo;Lee, Chong-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.354-363
    • /
    • 2005
  • Squeeze film dampers (SFDs) have been commonly used to effectively enhance the dynamic behavior of the rotating shaft supported by rolling element bearings. However, due to the recent trends of high operating speed, high load capacity and light weight in rotating machinery, it is becoming increasingly important to change the dynamic characteristics of rotating machines in operation so that the excessive vibrations, which may occurparticularly when passing through critical speeds or unstable regions, can be avoided. Semi-active type SFDs using magneto-rheological fluid (MR fluid), which responds to an applied magnetic field with a change in rheological behavior, are introduced in order to find its applications to rotating machinery as an effective device attenuating unbalance responses. In this paper, a semi-active SFD using MR fluid is designed, tested, and identified to investigate the capability of changing its dynamic properties such as damping and stiffness.In order to apply the MR-SFD to the vibration attenuation of a rotor, a systematic approach for determining the damper's optimal location is investigated, and also, a control algorithm that could improve the unbalance response characteristics of a flexible rotor is proposed and its control performance is validated with a numerical example.

Analysis of Magneto-rheological Fluid based Semi-active Squeeze Film Damper and Its Application to Unbalance Response Control of Rotor (자기유변유체를 이용한 반능동형 스퀴즈 필름 댐퍼의 해석 및 회전체 불균형 응답 제어)

  • Kim, Keun-Joo;Lee, Chong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1005-1011
    • /
    • 2004
  • Squeeze film dampers (SFDs) have been commonly used to effectively enhance the dynamic behavior of the rotating shaft supported by rolling element bearings. However, due to the recent trends of high operating speed, high load capacity and light weight in rotating machinery, it is becoming increasingly important to change the dynamic characteristics of rotating machines in operation so that the excessive vibrations, which may occur particularly when passing through critical speeds or unstable regions, can be avoided. Semi-active type SFDs using magneto-rheological fluid (MR fluid), which responds to an applied magnetic field with a change in rheoloaical behavior, are introduced in order to find its applications to rotating machinery as an effective device attenuating unbalance responses. In this paper, a semi-active SFD using MR fluid is designed, tested and identified by means of linear analysis to investigate the capability of changing its dynamic properties such as damping and stiffness. Furthermore, the proposed device is applied to a rotor system to investigate its potential capability for vibration attenuation: an efficient method for selecting the optimal location of the proposed damper is introduced and control algorithm that could improve the unbalance response properties of a flexible rotor is also proposed.

  • PDF

A study on modeling and measuring method of tire weight imbalances and improving reliability (ICCAS 2004)

  • Lee, Ki-Seong;Jeong, Tae-Woon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1685-1688
    • /
    • 2004
  • I propose a modeling of a mechanism for weight fire uniformity measurement of a tire and a way I interpret a Sampling signal by Loadcell through an analysis, and to measure fire uniformity in this study. Correct a weight fire uniformity measurement was possible through the production of conversion and influence factor of a signal with a basis with the model who was an oscillation mechanics enemy.

  • PDF

A Study on the Elevator Overbalance-Ratio Control and Improved Scheme for Safety (엘리베이터 오버밸런스율 제어와 안전을 위한 개선방안 연구)

  • Lee, Ho-Cheol;Choi, Young-Kiu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2785-2792
    • /
    • 2013
  • An elevator is driven by the friction between the pulley and wire rope. A balancing counter weight is connected to the elevator car with a wire rope. This structure is essential to drive elevators while it always has weight unbalance problems on each side. The overbalance-ratio of elevators may be an important factor for safety and structural efficiency; however, it is not yet clearly defined in the Requirements of Korea Elevator Inspection. This paper describes these "weight unbalance ratio" for control of elevators to reduce the number of accidents. It includes the analysis of current elevator maintenance situations and also proposes some fundamental improvement schemes for safety.

Vibration Characteristics of a Synchro Clutch Coupling for Steam Turbine (증기터빈용 Synchro Clutch Coupling의 진동 특성)

  • Shim, Eung-Gu;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.66-72
    • /
    • 2008
  • The vibration of steam turbine is caused by Mass unbalance, Shaft misalignment, Oil whip and rubbing etc. But in turbine which is normally operated and maintained, the Mass unbalance component possesses the greatest portion. Our power plant has two steam turbines in capacity of 200 MW and 135 MW respectively and each turbine is supported by 6 journal bearings. However, we had many difficulties because the vibration amplitude of #3 and #4 Bearings was high during the start-up and operation mode change of steam turbine. But, with this study, we completely solved the vibration problem caused by the mass unbalance of #1 steam turbine. Until a recent date, #3 and #4 bearings which support high pressure turbine for #1 steam turbine had shown about $135{\mu}m$ in vibration amplitude (sometimes it increased to $221{\mu}m$ maximum. alarm: 6 mils, trip: 9 mils) at base load. After applying the study, they decreased to about $45{\mu}m$ maximum. It is a result from that we did not change the setting value of bearing alignment and only changed the assembly position of internal parts in Synchro clutch coupling rachet wheel which links between high pressure turbine and low pressure turbine, and increased the internal gap and machining of the Pawl cage surface. In the operation of steam turbine, if the vibration value increases by 1X, we should reduce the vibration of bearing by weight balancing. However, unless the vibration of bearing is declined by the balancing, we will have to disassemble and check the component and find the cause. In this study, we researched the way to lower mass unbalance that is 1X vibration component which has the greatest portion of vibration generated by steam turbine and we got good result by applying the findings of this study.

  • PDF

A study on Mass Unbalance Vibration Generated from 200MW Steam Turbine Synchro Clutch Coupling (증기터빈용 Synchro Clutch Coupling에서 발생하는 진동에 관한 연구)

  • Shim, Eung-Gu;Kim, Young-Kyun;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.232-235
    • /
    • 2008
  • The vibration of steam turbine is caused by Mass Unbalance, Shaft Misalignment, Oil Whip and Rubbing etc. but in turbine which is normally operated and maintained, the Mass Unbalance component possesses the greatest portion. Our power plant has two steam turbines in capacity of 200MW and 135MW respectively and each turbine is supported by 6 journal bearings. However, we had many difficulties because the vibration amplitude of No 3 and 4 Bearings was high during the start-up and operation mode change of steam turbine. But, with this study, we completely solved the vibration problem caused by the mass unbalance of No 1 steam turbine. Until a recent date, No 3 and 4 bearings which support high pressure turbine for No 1 steam turbine had shown about 135${\mu}$m in vibration amplitude (sometimes it increased to 221${\mu}$m maximum. alarm: 6mils, trip: 9mils) at base load. After applying the study, they decreased to about 40${\mu}$m maximum. It is a result from that we did not change the setting value of Bearing Alignment and only changed the assembly position of internal parts in Synchro Clutch Coupling Rachet Wheel which links between high pressure turbine and low pressure turbine, and increased the internal gap and machining of the Pawl stopper surface. In the operation of steam turbine, if the vibration value increases by 1X, we should reduce the vibration of bearing by weight balancing. However, unless the vibration of bearing is declined by the balancing, we will have to disassemble and check the component and find the cause. In this study, We researched the way to lower mass unbalance that is 1X vibration component which has the greatest portion of vibration generated by steam turbine and We got good result by applying the findings of this study.

  • PDF

Kinematic Analysis and Dynamic Balancing Technique in a Link-Motion Mechanism (링크모션 메커니즘의 기구학적 분석 및 다이나믹 발란싱 테크닉)

  • Suh, Jin-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.498-502
    • /
    • 2004
  • In a link-motion mechanism, numerous links are interconnected and each link executes a constrained motion at a high speed. Due to the complicated constrained motions of the constituent links, dynamic unbalance forces and moments are generated and transmitted to the main frame. Therefore unwanted vibration is produced. This degrades productivity and precise work. Based on constrained multi-body dynamics, the kinematic analysis is carried out to enable design changes to be made. This will provide the fundamental information for significantly reducing dynamic unbalance forces and moments which are transmitted to the main frame. In this work, a link-motion punch press is selected as an example of a link-motion mechanism. To calculate the mass and inertia properties of every link comprising a link-motion punch press, 3-dimensional CAD software is utilized. The main issue in this work is to eliminate the first-order unbalance force and moment in a link-motion punch press. The mass, moment of inertia link length, location of the mass center in each link have a great impact on the degree of dynamic balancing which can be achieved maximally. Achieving good dynamic balancing in a link motion punch press is quite essential fur reliable operation at high speed.

  • PDF