• Title/Summary/Keyword: Underwater Ultrasound

Search Result 9, Processing Time 0.036 seconds

Characteristics of Backscattering of Harmful Algae Using Underwater Ultrasound (수중 초음파를 이용한 적조 플랑크톤의 후방산란 특성)

  • Kim Eunhye;Bok Tae-hoon;Na Jungyul;Paeng Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.447-453
    • /
    • 2005
  • Laboratory measurements were performed in a uni-algae medium Cochlodinium polykrikoides (Phytoplankton, dinoflagellates) using an Underwater Ultrasound $(5\~15\;MHz)$ to study Characteristics of Acoustic Backscattering of Harmful algae. In an effort to detect the harmful algal scatterers with population density of less than 300 cells/ml that corresponds to the precaution stage of red tide, backscattered signals from various scatterer-density samples were obtained and analyzed. Correlations between volume backscattering strength (Sv) and population density (cells/ml) of scatterers in the medium have been investigated. Comparison of Volume Backscattering Strengths calculated with the fluid-sphere model [1] and the measured values showed an agreement.

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography (초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.4 s.287
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

Compact AUV platform system designed for the experiment of underwater multi-agent development

  • Watanabe, Keisuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2036-2041
    • /
    • 2005
  • The underwater multi-agent technology has many potential for the various activities related to ocean development/conservation in the near future. For example, in such fields as water pollution investigation, aquaculture control, or coral reef research, we feel a growing need for a system that realizes underwater continuous monitoring in the wide rang e. In this case, the target monitoring area will be sliced planar hierarchically toward the depth as monitoring layers, and many AUVs arranged on each layer track the given trajectory and gather various environmental information continuously, with communicating each other in the layer or with other layers. To realize those systems we need to develop AUV multi-agent technologies. So we are now building basic systems for basin experiment for the development of AUV multi-agent behavior. We must experience many situations and problems to be solved for the development of its elemental technologies by using real systems as well as our computer simulations. In this paper we introduce our concept of the experiment in the near future and the hardware/software design of our two types of handy AUVs and ultrasound ranging/communication system for that experiment. One AUV is designed using a 17inches-diameter glass sphere with DOS/V and RT-Linux based subsystems, which is intended to use not only in the basin but also in the calm real sea. The other AUV is designed for the basin experiment using a 7inches-diameter acrylic sphere with low-cost embedded system with SH-2 based subsystems. The basin experiment to verify the basic AUV facilities and ultrasound ranging for position detection was carried out.

  • PDF

MIMO Vector Channel Modeling and Performance Analysis in Underwater Channel Environments (수중 MIMO 벡터 채널 모델링 및 성능 분석)

  • Lee, Deok-Hwan;Ko, Hak-Lim;Lim, Yong-Kon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.426-431
    • /
    • 2007
  • In this paper we have studied the underwater vector channel modeling for MIMO(Multiple Input Multiple Output) to increase the performance and efficiency for ultrasound communication in underwater channel environments. Also we have analyzed the MIMO techniques using the proposed channel modeling. For underwater MIMO channel modeling. experiments were done in real channel environments and the data were analyzed to estimate parameters such as fading, Doppler, time delay, angle of arrival, and receiving power. These were used for modeling of underwater vector channel modeling for MIMO. Additionally, we have analyzed the performance of MIMO systems using our proposed channel models. As a result we could see that the BER has decreased severely with the same SNR when using the MIMO system.

The design technique of the underwater anechoic basin in KRISO and its acoustic characteristics in ultrasound region. (무향 수조의 설계 기법 및 초음파 영역에서의 음향학적 특성)

  • 김시문;임용곤;이종무;박종원;최영철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.350-355
    • /
    • 2001
  • In order to verify the performance of acoustic-based communication systems, a reliable check-up method is needed, which simulates similar oceanic conditions in low cost. One of the possible candidates would be the performance test in an underwater anechoic basin producing no reflecting waves. For this purpose KRISO (Korea Research Institute of Ships and Ocean Engineering) have constructed an underwater semi-anechoic basin from 1999 to 2001. This paper describes its design procedure, especially, how the material and size of the absorbing walls were chosen. Experiments were also performed to check its anechoic quality, Comparing the results with simple analytical results we concluded that the anechoic basin is working well for some selected frequency ranges.

  • PDF

Design of Low-Power Hybrid LNA with Multi-Input for Mobile Ultrasound System (이동형 초음파시스템에 적합한 다중 입력방식의 저전력 혼성 저잡음 증폭기 설계)

  • Song, Jae-Yeol;Lee, Kyung-Hoon;Park, Sung-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Ultrasound system is one of the complex wireless signal processing systems that are widely used in the fields of modern industry such as medical diagnostics, underwater communications, and sensor-networks. Miniaturization of ultrasound system has been raging recently. In this paper, a hybrid LNA that is suitable for miniaturization and mobile diagnostic ultrasound system has been developed. The proposed LNA has low noise figure of less than 5dB, and the feedback resistor is designed to be electrically adjusted in order to attain the impedance-matching for various ultrasound transducers. It supports the whole ultrasound frequencies from 10KHz to 150MHz frequency band and also provides sleep modes. A gain from -18.8 to -29.5 dB is achieved by adjusting each transducer to fit the system character. Power consumption can be reduced up to 90% in similar performance as compared to the existing LNA.

The Study of Voice and Data Transmission System using Underwater Ultrasound (수중초음파를 이용한 음성 및 데이터전송 시스템에 관한 연구)

  • Cho, Hyeok;Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.163-166
    • /
    • 2002
  • The underwater acoustic communication has been widely applied to various objects such as ocean exploration-development and military affairs. And recently for embodiment of the communication system that is installed in a submarine and underwater work system, many studies have been progressing. This scope of the main studies in the meantime. It made it possible for a diver and a scuba diver who arc difficult to notice the situation of the outside because of staying in the water to hear a sound through a small speaker by using a ultra sound transducer that a central frequency is 32KHz after modulation of a voice to give the information of the outside. Also in case of happening an emergency to a diver in the water, it made him/her ask for help to a person in the outside by pressing a key and send a letter data to a person in the outside by using a keyboard. Through this system, it is possible to send a voice or data between the underwater and the outside and it is available to a diver or skin scuba diver.

  • PDF

A Study of Improve on a Backscatter Data of Multibeam Echo-sounder Using Digital Image Processing (디지털 영상처리기법를 이용한 멀티빔 음향측심기의 음압자료 향상 연구)

  • Hye-Won Choi;Doo-Pyo Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.133-141
    • /
    • 2023
  • Accurate measurement of seafloor topography plays a crucial role in developing marine industries such as maritime safety, resource exploration, environmental protection, and coastal management. The seafloor topography is constructed using side scan sonar (SSS) and single beam echosounder (SBES) or multibeam echosounder (MBES), which transmit and receive ultrasound waves through a device attached to a marine survey vessel. However, the use of a sonar system is affected by noise pollution areas, and the single beam has a limited scope of application. At the same time, the multibeam is mainly applicable for depth observation. For these reasons, it is difficult to determine the boundaries and areas of seafloor topography. Therefore, this study proposes a method to improve the backscatter data of multibeam echosounder, which has a relationship with the seafloor quality, by using digital image processing to classify the shape of the underwater surface.