• Title/Summary/Keyword: Utility Interactive Photovoltaic System

Search Result 96, Processing Time 0.041 seconds

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

A filed operation characteristics and the controversial point of Photovoltaic power generation system (태양광 발전시스템의 현장 운전특성 및 문제점)

  • Koh, Kang-Hoon;Suh, Ki-Young;Lee, Hyun-Woo;Hong, Doo-Sung;Gang, Yeong-Cheol;U, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.381-383
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using da transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

A study of on the Efficiency Analysis for 3kW Utility interactive PV System (3kW 태양광발전시스템의 효율분석에 관한 연구)

  • Park, J.M.;Lim, H.W.;Choi, Y.O.;Lee, S.G.;Cho, G.B.;Baek, H.N
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.61-63
    • /
    • 2005
  • Utility interactive photovoltaic systems is one of the most premising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because utility power may be used to supplement photovoltaic systems when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility inter-tied. In this paper, Principle and operating characteristic of Utility Interconnected Photovoltaic System is presented. For the purpose of optimal utility Inter-tied photovoltaic system design and installation. It is that demonstrate throughout the installed 3 PV system respectively, 3kW utility interconnected residential system.

  • PDF

A Utility Interactive Photovoltaic Generation System using PWM Chopper and Current Source Inverter (PWM 쵸퍼와 전류형 인버터를 이용한 계통연계형 태양광발전시스템)

  • 이승환;성낙규;오봉환;검성남;이훈구;김용주;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.323-329
    • /
    • 1998
  • In this paper, we compose of the utility interactive photovoltaic(PV) generation system with a PWM stepdown chopper and a current source inverter. The stepdown chopper is controlled by the several gate pulses (twice frequency of utility voltage, square pulse and without the chopper) of chopper part to reduce pulsation of DC current and size of DC reactor. PV current only is measured for maximum power point tracking without any influence on the variation of insolation and temperature. Therefore, we can control modulation factor of the chopper to operate at maximum power point of solar cell. And, the utility interactive photovoltaic generation system supplies an AC power to the load and the utility power system.

  • PDF

The Construction and Operating Characteristics analysis of Utility interactive PV power generation system (계통연계형 태양광 발전시스템의 운전특성 해석과 문제점 분석)

  • Hong, D.S.;Koh, K.H.;Koh, H.S.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.334-336
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller PLL control system and the phase detector of interactive voltage by using do transformation. The proposed inverter system provides a sinusoidal are current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

The Utility Power Factor Control system of Photovoltaic Power Generation System

  • Koh Kang-Hoon;Lee Hyun-Woo;Suh Ki-Young;Taniguchi Katsunori
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.673-676
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel, which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

Operationg Characteristics of 50kW Utility Interactive Photovoltaic System (목포대학교 기숙사 30[kW]급 태양광발전시스템 발전특성)

  • Moon, Chae-Joo;Lim, Joung-Min;Cheang, Eui-Heang;Park, Sang-Jin;Park, Gui-Yeol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.53-56
    • /
    • 2008
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system used infinity of solar energy, cost of fuel is needless and there in no air pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 30[kW] large scale applications installed in Mokpo National University dormitory roof. The status of photovoltaic system components, are inter-connection and safety equipment monitoring system will be summarized as this article. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory. In this paper represent 30[kW] utility photovoltaic system examination result.

  • PDF

Implementation of the 50kW Utility Interconnected Photovoltaic System Simulator (50kW급 계통연계형 태양광발전시스템의 시뮬레이터 구현)

  • Jeong, Byeong-Ho;Park, Jeong-Min;Cho, Geum-Bae;Baek, Hyung-Lae;Chung, Soo-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.21-27
    • /
    • 2005
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW middle scale applications installed in Cho-sun University dormitory roof. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination and developed simulation results. The performance of photovoltaic system has been evaluated and analyzed with simulation. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

Modeling of utility interactive photovoltaic system DC-DC converter (태양광 발전 시스템용 DC-DC 컨버터의 모델링)

  • Mun, S.P.;Park, Y.J.;Kim, Y.M.;Kang, W.J.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.215-217
    • /
    • 2002
  • In this paper, a new converter for utility interactive photovoltaic system is proposed, the conventional utility interactive photovoltaic system is composed of a PWM inverter and a DC converter. However, the increased switching loss and the high frequency switching noise become a problem. the control accuracy of the system is made to lower by the dead time of the switching devices. and it becomes a cause of the lower conversion efficiency. In order to resolve those problems, we applied a non- dissipative snubber circuit to a converter, which generates the single phase absolute value of sinusoidal current. the converter consists of two switching devices and one capacitor which constitute a non-dissipative snubber circuit. the proposed circuit is very useful to minimize and increase efficiency, when it is used to an utility interactive photovoltaic system. it is confirmed by simulation that the proposed converter for new photovoltaic system has stable operation and good output.

  • PDF

Modeling for Utility Interactive Photovoltaic Power Generation System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 태양광 발전시스템의 배전계통 연계운전을 위한 모델링)

  • Kim, Woo-Hyun;Kang, Min-Kyu;Kim, Eung-Sang;Kim, Ji-Won;Ro, Byong-Kwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1180-1182
    • /
    • 1999
  • Modeling for utility interactive photovoltaic power generation system has been studied using PSCAD/EMTDC. The proposed model system consists of a simple utility circuit configuration, 3kW of single phase utility interactive photovoltaic system, single phase PWM voltage source inverter module, and feed forward PID controller as control circuit. In the system, the DC current is assumed constant, and the voltage source inverter provides sinusoidal ac current for the loads of utility system. The simulation results are given in order to verify the effectiveness of the proposed model. The phases of output voltage of utility system and the output current of the inverter module are compared. Especially, the compensation effect of the photovoltaic system for the unbalanced load is analyzed. and the transient phenomena for a phase to ground fault are also simulated.

  • PDF