• Title/Summary/Keyword: V-factor

Search Result 2,446, Processing Time 0.031 seconds

V-Factor Estimation Under Thermal and Mechanical Stress for Circumferentially Cracked Cylinder (열하중 및 기계하중이 작용하는 원주 방향 균열 배관에 대한 V-계수 평가)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1123-1131
    • /
    • 2008
  • This paper provides V-factor estimation under combined mechanical and thermal load for circumferential cracks. Results are based on finite element analyses and effect of types and magnitudes of the thermal stress, crack geometry, the loading mode and plastic strain hardening on variations of the V-factor are investigated. The results of finite element analyses are compared with R6 values. As a result, it is shown that R6 gives generally conservative results. The conservatism is especially increased for the combination of large mechanical and thermal load. As a result, new estimation method which uses failure assessment line in R6 is proposed for V-factor and gives less conservative results.

SHARP CONDITIONS FOR THE EXISTENCE OF AN EVEN [a, b]-FACTOR IN A GRAPH

  • Cho, Eun-Kyung;Hyun, Jong Yoon;O, Suil;Park, Jeong Rye
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.1
    • /
    • pp.31-46
    • /
    • 2021
  • Let a and b be positive integers, and let V (G), ��(G), and ��2(G) be the vertex set of a graph G, the minimum degree of G, and the minimum degree sum of two non-adjacent vertices in V (G), respectively. An even [a, b]-factor of a graph G is a spanning subgraph H such that for every vertex v ∈ V (G), dH(v) is even and a ≤ dH(v) ≤ b, where dH(v) is the degree of v in H. Matsuda conjectured that if G is an n-vertex 2-edge-connected graph such that $n{\geq}2a+b+{\frac{a^2-3a}{b}}-2$, ��(G) ≥ a, and ${\sigma}_2(G){\geq}{\frac{2an}{a+b}}$, then G has an even [a, b]-factor. In this paper, we provide counterexamples, which are highly connected. Furthermore, we give sharp sufficient conditions for a graph to have an even [a, b]-factor. For even an, we conjecture a lower bound for the largest eigenvalue in an n-vertex graph to have an [a, b]-factor.

RELATIVE SEQUENCE ENTROPY PAIRS FOR A MEASURE AND RELATIVE TOPOLOGICAL KRONECKER FACTOR

  • AHN YOUNG-HO;LEE JUNGSEOB;PARK KYEWON KOH
    • Journal of the Korean Mathematical Society
    • /
    • v.42 no.4
    • /
    • pp.857-869
    • /
    • 2005
  • Let $(X,\;B,\;{\mu},\;T)$ be a dynamical system and (Y, A, v, S) be a factor. We investigate the relative sequence entropy of a partition of X via the maximal compact extension of (Y, A, v, S). We define relative sequence entropy pairs and using them, we find the relative topological ${\mu}-Kronecker$ factor over (Y, v) which is the maximal topological factor having relative discrete spectrum over (Y, v). We also describe the topological Kronecker factor which is the maximal factor having discrete spectrum for any invariant measure.

Long-Term Expression of von Willebrand Factor by a VSV-G Pseudotyped Lentivirus Enhances the Functional Activity of Secreted B-Domain-deleted Coagulation Factor VIII

  • Park, Sang Won;Choi, Sang-Yun
    • Molecules and Cells
    • /
    • v.24 no.1
    • /
    • pp.125-131
    • /
    • 2007
  • von Willebrand factor (vWF) is a multimeric glycoprotein which functions within the coagulation system. It colocalizes with factor VIII (FVIII) by non-covalent interaction and alters its intracellular trafficking. vWF is also instrumental in maintaining the stability of secreted FVIII. The principal objective of this study was to generate a lentivirus-based vWF expression vector for gene therapy of hemophilia A. We inserted a vWF of 8.8 Kb into a lentiviral vector thereby producing VSV-G-pseudotyped vEx52. However, its titer was quite low, presumably because the length of vWF gene exceeds the size limit of the lentiviral vector. In order to overcome the low-titer, we concentrated the vEx52 and thus increased the efficiency of transduction approximately 6-fold with $1/100^{th}$ of the volume. However, as concentration requires an additional laborious step, we attempted to enhance the transduction efficiency by deleting exons 24-46 and 29-46 in pRex52 to construct pRex23 and pRex28, and in pvEx52, yielding pvEx23 and pvEx28, respectively. The transfected pRex52 had a profound effect on the activity of secreted FVIII, and this activity declined as domains of vWF were deleted. However, when the domain-deleted vWF-lentiviruses were transduced into K562 cells, the vEx28 increased the activity of the secreted FVIII compared to what was observed with vEx52. This result is probably due to higher efficiencies of transduction and expression while retaining the essential domains required for proper interaction with FVIII.

Interaction of thermal stress with mechanical stress in circumferentially cracked pipe (원주방향 균열배관에 대한 열하중 및 기계하중의 상호 작용)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.327-332
    • /
    • 2008
  • For the cracked component under combined primary and secondary stress, an interacion between the loads occurs and the secondary stress is relaxed by the primary load. To account for this phenomena, R6 code provides the correction factor which is called V-factor. However, evaluation corrected with V-factor need to be examined for its conservatism. In this paper the conservatism of the current V-factor is examined for the circumferentially cracked pipe under the combined load and new evaluation method is proposed to reduce the conservatism.

  • PDF

Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber

  • Yu, Jili;Wu, Jinjie;Liao, Zhenyu;Zhou, Zhenjie
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1466-1472
    • /
    • 2018
  • A key comparison has been made between the air-kerma standards of the National Institute of Metrology (NIM), China, and other Asia Pacific Metrology Programme (APMP) members in the medium-energy X-ray. This paper reviews the primary standard Free-air ionization chamber correction factor experimental method and Monte Carlo simulation method in the NIM. The experimental method and the Monte Carlo simulation method are adopted to obtain the correction factor for the medium-energy X-ray primary standard free-air ionization chamber at 100 kV, 135 kV, 180 kV, 250 kV four CCRI reference qualities. The correction factor has already been submitted to the APMP as key comparison data and the results are in good agreement with those obtained in previous studies. This study shows that the experimental method and the EGSnrc simulation method are usually used in the measurement of the correction factor. In particular, the application of the simulation methods is more common.

The Study on the Performance Evaluation of IPTV according to the increase of network traffic on the Internet Environment (인터넷환경에서 트래픽증가에 따른 IPTV 성능평가에 관한 연구)

  • Cho, Tae-Kyung
    • Journal of Digital Convergence
    • /
    • v.13 no.11
    • /
    • pp.179-185
    • /
    • 2015
  • In this paper, we research the IPTV that is the convergence technique of TV and network technique and performed the performance evaluation of picture quality of IPTV in the situation of increasing the network traffic in the Internet environment. To do this, we constructed the mock Internet network similar to the real Internet environment and measured the quality of received video using V-Factor model according to the increase of network traffic, and analyzed the result of the experiment. Making use of the result of this paper for the threshold value of V-Factor, the measured factor of network performance, the measured factor of video performance in the watchable IPTV video quality.

[2,3]-FACTORS IN A 3-CONNECTED INFINITE PLANAR GRAPH

  • Jung, Hwan-Ok
    • Journal of applied mathematics & informatics
    • /
    • v.10 no.1_2
    • /
    • pp.27-40
    • /
    • 2002
  • For two integers m, n with m $\leq$ n, an [m,n]-factor F in a graph G is a spanning subgraph of G with m $\leq$ d$\_$F/(v) $\leq$ n for all v ∈ V(F). In 1996, H. Enomoto et al. proved that every 3-connected Planar graph G with d$\_$G/(v) $\geq$ 4 for all v ∈ V(G) contains a [2,3]-factor. In this paper. we extend their result to all 3-connected locally finite infinite planar graphs containing no unbounded faces.

The Effect of Pile Length on the Handle and Physical Properties of Velvet (Velvet의 pile 길이가 촉감 및 물리적 특성에 미치는 영향)

  • 장정애;류덕환
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.3
    • /
    • pp.471-482
    • /
    • 1995
  • Using the acetate velvet and viscose velvet whose pile lengths were sheared as 1.45, 1.55, 1 65, 1.75, 1.85, 1.90mm under the condition equating the weaving process of ground fabric, the conclusions were as follows through the results of the sensory assessments estimated by women students in our university and the physical properties, H. V and T. H. V obtained by KES-F system. 1. In the sensory assessments estimated by the method of paired comparison and ranking of samples, the longer pile length was, the more the hand values of smoothness, softness, thickness, heaviness increased on the whole. 2. The H V. and T. H. V. measured by KES-F system were as follows; Kohi increased to pile length 1.85mm and then decreased a little at 1.90mm. hummer increased as pile length was longer. Fukurami increased to pile length 1.75mm and then decreased gradually as pile length was longer. Total hand value increased gradually from 1. 45mm to 1.85mm, had the top value at 1.85mm, and then decreased a little at 1.90mm. 3. In the results of summarizing $\ulcorner$the physical properties correlated closely with the H. V obtained by sensory assessments$\lrcorner$ and tithe Physical properties correlated closely with the H. V. and T. H. V obtained by KES-F systems, it showed that all the sensory properties correlated closely with compressive energy, flexural rigidity, thickness, weight and pile ratio in the former and that the physical properties correlated closely with each H V and T. H. V were different in the latter. 4. It showed that factor 1 was related to compressive energy, thickness, weight, pile ratio, factor 2 was related to recovery energy, compressive resilience, compressive index, and factor 3 was related to compressive recovery ratio in the result of factor analysis. 5. In the multiple repression analysis, the expressions of all sensory properties had compressive ratio, frictional coefficient in the regression expressions of $\ulcorner$H. V. obtained by sensory assessments$\lrcorner$, while the expressions of each H. V. and different physical properties in the regression expressions of $\ulcorner$H. V. obtained by KES-F system$\lrcorner$.

  • PDF

Use of a Transformed Diode Equation for Characterization of the Ideality Factor and Series Resistance of Crystalline Silicon Solar Cells Based on Light I-V Curves (Light I-V 곡선을 이용한 결정질 태양전지의 이상계수와 직렬 저항 특성 분석)

  • Jeong, Sujeong;Kim, Soo Min;Kang, Yoonmook;Lee, Hae-seok;Kim, Donghwan
    • Korean Journal of Materials Research
    • /
    • v.26 no.8
    • /
    • pp.422-426
    • /
    • 2016
  • With the increase in installed solar energy capacity, comparison and analysis of the physical property values of solar cells are becoming increasingly important for production. Therefore, research on determining the physical characteristic values of solar cells is being actively pursued. In this study, a diode equation, which is commonly used to describe the I-V behavior and determine the electrical characteristic values of solar cells, was applied. Using this method, it is possible to determine the diode ideality factor (n) and series resistance ($R_s$) based on light I-V measurements. Thus, using a commercial screen-printed solar cell and an interdigitated back-contact solar cell, we determined the ideality factor (n) and series resistance ($R_s$) with a modified diode equation method for the light I-V curves. We also used the sun-shade method to determine the ideality factor (n) and series resistance ($R_s$) of the samples. The values determined using the two methods were similar. However, given the error in the sun-shade method, the diode equation is considered more useful than the sun-shade method for analyzing the electrical characteristics because it determines the ideality factor (n) and series resistance ($R_s$) based on the light I-V curves.