• 제목/요약/키워드: Vacuum packaged process.

검색결과 26건 처리시간 0.02초

다결정 다공성 실리콘의 전계방출 특성 (Electron Emission From Porous Poly-Silicon Nano-Device for Flat Panel Display)

  • 이주원;김훈;이윤희;장진;주병권
    • 한국전기전자재료학회논문지
    • /
    • 제16권4호
    • /
    • pp.330-335
    • /
    • 2003
  • This paper reports the optimum structure of the vacuum packaged Porous poly-silicon Nano-Structured (PNS) emitter. The PNS layer was obtained by electrochemical etching process into polycrystalline silicon layer in a process controlled to anodizing condition. Current-voltage studies were carried out to optimize process condition of electron emission properties as a function of anodizing condition and top electrode thickness. Also, we measured in advance the electron emission properties as a function of substrate temperature because the vacuum packaged process was performed under the condition of high temperature ambient (430$^{\circ}C$). Auger Electron Spectrometer (AES) studies shows that Au as a top-electrode was diffused to PNS layer during temperature experiments. Thus, we optimized the thickness of top-electrode in order to make the vacuum package PNS emitter. As a result, the vacuum Packaged PNS emitter was successfully emitted by optimizing process.

Effect of Packaging and Antioxidant Combinations on Physicochemical Properties of Irradiated Restructured Chicken Rolls

  • Yim, Dong-Gyun;Ahn, Dong U.;Nam, Ki-Chang
    • 한국축산식품학회지
    • /
    • 제35권2호
    • /
    • pp.248-257
    • /
    • 2015
  • Effects of double packaging (combinational use of aerobic and vacuum conditions) and antioxidants on physicochemical properties in irradiated restructured chicken rolls were determined. Chicken breast treated with antioxidants (none, sesamol+a-tocopherol) was used to process restructured chicken breast rolls. The sliced rolls were vacuum, aerobic, or double packaged (vacuum for 7 d then aerobic for 3 d) and electron beam irradiated at 2.5 kGy. Color, 2-thiobarbituric acid reactive substances (TBARS), oxidation reduction potentials (ORP), and volatile profiles of the samples were determined at 0 and 10 d. Irradiation made restructured chicken rolls redder (p<0.05), and the increased redness was more distinct in irradiated vacuum-packaged than irradiated aerobic or double packaged meats. TBARS values of antioxidant-treated double packaged rolls were lower than even nonirradiated vacuum-packaged meat, and those were distinct at 10 d (p<0.05). ORP and lipid oxidation values were lower in irradiated vacuum and double packaged samples than those in irradiated aerobic packaged ones at 0 d (p<0.05). Irradiation of restructured chicken rolls increased the amount of total volatiles. Considerable amounts of off-odor volatiles were reduced or not detected by double packaging and antioxidant treatment at 10 d. Therefore, the combined use of antioxidants and double packaging would be useful to reduce redness and control the oxidative quality changes of irradiated restructured chicken rolls

Tubeless Packaging된 Field Emission Display의 개발 (Development of Tubeless-Packaged Field Emission Display)

  • 주병권;이덕중;이윤희;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.275-280
    • /
    • 1999
  • The glass-to-glass electrostatic bonding process in vacuum environment was developed and the tubeless-packaged FED was fabricated based on the bonding process. The fabricated tubeless-packaged FED showed stable field emission characteristics and potential applicability to the FED tubeless packaging and vacuum in-line sealing.

  • PDF

High vacuum packaging and vacuum evaluation for field emission display

  • Jung, S.J.;Woo, K.J.;Lee, N.Y.;Ahn, S.;Moon, G.J.;Kim, K.S.;Kim, M.S.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권1호
    • /
    • pp.95-97
    • /
    • 1999
  • A 3.12" FED panel was packaged successfully using the anode plate on which phosphors and black matrix were coated and cathode plate containing emitter arrays. The vacuum level of the panel was investigated during panel evacuation, tip-off and getter activation process. The packaged panel exhibited vacuum level below 2${\times}$10-6 Torr. Similar experiments were carried out for 10" panel made of bare plates. In addition, the vacuum level of two panels was compared continuously after tip off process; one with the getter and the other without it.

  • PDF

냉장 또는 동결우육에 있어서 저장기간과 재냉장이 연도에 미치는 영향 (Effects of Storage Period and Rechilling Process on Tenderness of Chilled or Frozen Beef)

  • 김미숙;문윤희
    • 한국축산식품학회지
    • /
    • 제18권3호
    • /
    • pp.216-223
    • /
    • 1998
  • This study was conducted to investigate the effects of the tenderness for the vacuum chilled, the air-frozen or the rechilled Holstein beef loin. The vacuum packaged beef was stored at 1$^{\circ}C$ and the air-packaged beef was stored at -20$^{\circ}C$ for 60 days. The rechilled beef was restored for 3 days at 1$^{\circ}C$ by using the vacuum chilled or the air-frozen beef. Hardness and chewiness of the vacuum chilled beef were better than those of the air-frozen beef. Hardness and chewiness were improved significantly(p<0.05) after the 40 days storage for the vacuum chilled beef, but there was no significant improvement for the air-frozen beef during the 60 days storage. By the rechilling process, tenderness and myofibrillar fragmentation index of the vacuum chilled and air-frozen beef improved. Especially those were improved significantly(p<0.05) in the vacuum chilled beef after the 20 days storage, and in the air-frozen beef after the 40 and 60 days storage.

  • PDF

The Influence of Vacuum Packaging of Hot-Boned Lamb at Early Postmortem Time on Meat Quality during Postmortem Chilled Storage

  • Zhao, Yingxin;Chen, Li;Bruce, Heather L.;Wang, Zhenyu;Roy, Bimol C.;Li, Xin;Zhang, Dequan;Yang, Wei;Hou, Chengli
    • 한국축산식품학회지
    • /
    • 제42권5호
    • /
    • pp.816-832
    • /
    • 2022
  • To evaluate the effects of early postmortem vacuum packaging (VP) on meat quality during postmortem chilled storage, hot-boned lamb was vacuum-packaged at 1, 6, 12, 24, and 48 h postmortem and stored around 2℃ until 168 h postmortem, with lamb packaged in plastic wrap as the control (aerobic packaging). Intramuscular pH decline was delayed when lamb was vacuum packaged at 1, 6, and 12 h postmortem (p<0.05). The lamb vacuum-packaged at 1 h postmortem (VP-1h group) had significantly lower shear force values and purge losses accompanied by lower free thiol group values than other treatments during postmortem storage and was also higher in extractable calpain-1 activity by 6 h postmortem (p<0.05). Free thiol group concentrations were significantly higher after VP at 6 and 12 h postmortem (p<0.05). Packaging lamb under vacuum very early postmortem produced the lowest shear force and purge loss, likely by slowing heat loss and muscle temperature decline, implying that lamb quality is improved by VP when applied very early postmortem. This was at the expense of protein oxidation, which was unrelated to other meat quality measurements, most likely because potential contracture during hot boning confounded its impact. Further research is required to understand the implications of the interaction between protein oxidation, VP, and hot boning on the acceptability of lamb.

Epi poly를 이용한 MEMS 소자용 웨이퍼 단위의 진공 패키징에 대한 연구 (A Study on Wafer Level Vacuum Packaging using Epi poly for MEMS Applications)

  • 석선호;이병렬;전국진
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.15-19
    • /
    • 2002
  • A new vacuum packaging process in wafer level is developed for the surface micromachining devices using glass silicon anodic bonding technology. The inside pressure of the packaged device was measured indirectly by the quality factor of the mechanical resonator. The measured Q factor was about 5$\times10^4$ and the estimated inner pressure was about 1 mTorr. And it is also possible to change the inside pressure of the packaged devices from 2 Torr to 1 mTorr by varying the amount of the Ti gettering material. The long-term stability test is still on the way, but in initial characterization, the yield is about 80% and the vacuum degradation with time was not observed.

  • PDF

대기압형 단결정 실리콘 MEMS 각속도계의 설계, 제작 및 성능 측정 (Design, Fabrication and Performance Test of A Non-Vacuum Packaged Single Crystalline Silicon MEMS Gyroscope)

  • 정형균;황영석;성운탁;장현기;이장규;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1635-1636
    • /
    • 2006
  • In this paper, a non-vacuum packaged single crystalline silicon MEMS gyroscope is designed, fabricated and tested. To reduce air damping of the gyroscope structure for non-vacuum packaging, air damping model is used and damping is minimized by analysis. The inner and outer spring length is optimized by ANSYS simulation for rigid body motion. The gyroscope is fabricated by SiOG(Silicon On Glass) process. The performance of the gyroscope is measured to evaluate the characteristic of the gyroscope. The sensitivity, non-linearity, noise density and the bias stability are measured to 9.7693 mV/deg/s, 04265 %, 2.3 mdeg/s/rtHz and 16.1014 deg/s, respectively.

  • PDF

비정질 실리콘 박막을 이용한 Sodalime-Sodalime 정전 열 접합 및 FEA Packaging 응용 (Sodalime-sodalime Electrostatic Bonding using Amorphous Silicon Interlayer and Its Application to FEA Packging)

  • 주병권;이덕중;최우범;김영조;이남양;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.656-661
    • /
    • 1999
  • As a fundamental study for FED tubeless packaging, sodalime-sodalime electrostatic bonding was performed by using on the developed bonding mechanism. Thebonding properties of the bonded sodalime-sodalime structure were investigated through SEM and SIMS analyses. Mo-tip FEA was vacuum-packaged by the developed bonding process and the packaged device generated the field emission current.

  • PDF

최적 증착 속도로 형성된 MgO를 갖는 인-라인 진공 실장된 플라즈마 디스플레이 패널의 방전 특성에 관한 연구 (A Study on Discharge Characteristics of the PDP Packaged with In-situ Vacuum Sealing with the MgO Protective Layer Deposited by Optimal Evaporation Rate)

  • 이조휘;조의식;권상직
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.916-922
    • /
    • 2008
  • AC PDP with MgO protective layer coated with the optimum evaporation rate of $5{\AA}/s$ can generate more enhanced efficiency through the vacuum in-line sealing process. However, the optimized process conditions still require the optimum driving scheme on the ramp-up and ramp-down slope of the reset waveform for enhancing the efficiency. In this paper, for the in-situ vacuum sealed PDP with the optimum evaporation rate of MgO protective layer, the address delay time was investigated with various slopes of ramp waveform during a reset ramp-up and ramp-down period. In this study, the minimum statistical delay time was obtained at the ramp-up rate of $6.0 V/{\mu}s$ and the ramp-down rate of $0.7 V/{\mu}s$ of the reset waveform.