• Title/Summary/Keyword: Vacuum system modeling

Search Result 40, Processing Time 0.042 seconds

Simulation of Modeling Characteristics of Pumping Design Factor on Vacuum System

  • Kim, Hyung-Taek;Cho, Han-Ho
    • International journal of advanced smart convergence
    • /
    • v.5 no.2
    • /
    • pp.1-7
    • /
    • 2016
  • Recently, with the development of advanced thin film devices comes the need for constant high quality vacuum as the deposition pressure is more demanding. It is for this reason our research seeks to understand how the variable design factors are employed in such vacuum systems. In this study, the effects of design factor applications on the vacuum characteristics were simulated to obtain the optimum design modeling of variable models on an ultra high vacuum system. The commercial vacuum system simulator, $VacSim^{(multi)}$, was used in our investigation. The reliability of the employed simulator was verified by the simulation of the commercially available models of ultra high vacuum system. Simulated vacuum characteristics of the proposed modeling aligned with the observed experimental behavior of real systems. Simulated behaviors showed the optimum design models for the ideal conditions to achieve optimal pressure, pumping speed, and compression ratio in these systems.

Simulation of Conductance Effects on Vacuum Characteristics of High Vacuum System for Semiconductor Processing (반도체공정 고진공시스템 진공특성에 대한 배기도관 컨덕턴스 영향 전산모사)

  • Kim, Hyung-Taek;Seo, Man-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.4
    • /
    • pp.287-292
    • /
    • 2010
  • Effect of conductance factors on performance of vacuum system was simulated for optimum design of vacuum system. In this investigation, the feasibility of modeling mechanism for VacSim$^{Multi}$ simulator was proposed. Application specific design of vacuum system is required to meet the particular process conditions for various industrial implementations of vacuum equipments. Geometry and length, diameter of exhaust pipeline were modeled as simulation modeling variables for conductance effects. Series vacuum system was modeled and simulated with varied dimensions and structures of exhaust pipeline. Variation of pipeline diameter showed the more significant effects on vacuum characteristics than that of pipeline length variations. It was also observed that the aperture structure of pipeline had the superior vacuum characteristics among the modeled systems.

Simulation of Vacuum Characteristics by Applications of Vacuum Valves in Display Processing (디스플레이공정 진공시스템 밸브응용에 따른 진공특성 전산모사)

  • Kim, Hyung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.77-83
    • /
    • 2012
  • Effect of valve conductance on performance of vacuum system was simulated for optimum design of vacuum system. In this investigation, the feasibility of modeling mechanism for VacSimMulti simulator was proposed. Application specific design of vacuum system is required to meet the particular process conditions for various industrial implementations of vacuum equipments. Geometry and length, diameter of vacuum valve were modeled as simulation modeling variables for conductance effects. Series vacuum system was modeled and simulated with varied dimensions and structures of exhaust valves. Variation of valve diameter showed the more significant effects on vacuum characteristics than that of pipeline length variations. It was also observed that the aperture structure of valve had the superior vacuum characteristics among the modeled systems.

DR VACUUM CO., LTD.

  • 이찬용
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.30-30
    • /
    • 2000
  • 당사는 각종 진공 장비를 개발/제작한 경험을 바탕으로 25년 동안 진공 산업 발전에 기여하여 왔으며 자체 기술로 HIGH VACUUM 응용시스템 설계 및 제작하고 있다. 이와 함께 3D CAD를 이용한 consulting 및 Modeling 분석을 수행하여, 자체 기술로 설계 및 제작 판매하고 있다. Vacuum System은 In-line System (ITO, SiO2, Cr Tio2, Ag, Al 등), Roll to Roll(Web) Sputtering system (ITO, SiO2, Ar, Metal 등), 유기 EL 박막 진공 증착 장치, PECVD System, Evaporator 시스템 등을 제작 공급하고 있다. 현재 Roll to Roll(Web) Sputtering System은 Dual Cathode를 사용하는 방식으로 개발중에 있으며, 평판 디스플레이용 대면적 Glass를 위한 In-line Sputtering System을 같이 개발하고 있다.

  • PDF

Simulation of Vacuum Characteristics of High Vacuum System Modelled by VacCAD

  • Kim, Hyungtaek;Park, Junhyung;Yun, Gyeongah
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.84-91
    • /
    • 2018
  • In this paper, we simulated three different HV systems and analyzed of each vacuum characteristics by VacCAD modelling. In each of modelled vacuum systems, selection of chamber materials, combination of rough pump with high vacuum pump and conductance of roughing line (diameter and length) were proposed as system variables. In the modelling of chamber materials, the pumping times to ultimate pressures of different chamber materials (stainless steel, aluminum) were compared by the variations of chamber volume. In this model, the effects of outgassing dependent on the chamber materials was also simulated and aluminum was estimated to optimum chamber materials. It was also obtained that modelling of vane and roots pump with diffusion pump and diameter, length of $50{\times}250$ [mm]roughing line were characterized as optimum variables to reach the ultimate pressure of 10E-7 [mbar] most effectively. Optimum design factors for vacuum characteristics of modelled vacuum system were achieved by VacCAD simulations. Feasibility of VacCAD as vacuum simulator was verified and applications of VacCAD expected to be increased to fields in vacuum needed.

A Comparison of Simulation Characteristics of VacCAD and VacTran as Vacuum Simulator

  • Hyung-Taek Kim
    • International journal of advanced smart convergence
    • /
    • v.12 no.4
    • /
    • pp.217-223
    • /
    • 2023
  • In this study, we compared the VacCAD and VacTran, commercial vacuum simulators, to investigate the simulation applicability and efficiency as vacuum simulation software. It was verified on reliability and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and employed vacuum materials. First, usability of simulation schematics was estimated through the modeling tools and the overall simulation characteristics of each simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping performance characteristics of commercial high vacuum system models. In addition, the degree of tolerances on both simulators was also evaluated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacTran has been presented, and it was also expected that the utilization of VacTan in vacuum applications to be increased due to the higher availability of modelling variations.

Modeling and Control of an Electronic-Vacuum Booster for Vehicle Cruise Control

  • Lee, Chankyu;Kyongsu Yi
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1314-1319
    • /
    • 2002
  • A mathematical model and control laws for an Electronic-Vacuum Booster (EVB) for application to vehicle cruise control will be presented. Also this paper includes performance test result of EVB and vehicle cruise control experiments. The pressure difference between the vacuum chamber and the apply chamber is controlled by a PWM-solenoid-valve. Since the pressure at the vacuum chamber is identical to that of the engine intake manifold, the output of the electronic-vacuum booster Is sensitive to engine speed. The performance characteristics of the electronic-vacuum booster have been investigated via computer simulations and vehicle tests. The mathematical model of the electronic-vacuum booster developed in this study and a two-state dynamic engine model have been used in the simulations. It has been shown by simulations and vehicle tests that the EVB-cruise control system can provide a vehicle with good distance control performance in both high speed and low speed stop and go driving situations.

A study on Applicability of VacCAD Simulator

  • Kim, Hyung-Taek;Kim, Kang-Won
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.200-206
    • /
    • 2019
  • In this study, we compared the VacCAD and VacSim(Multi), commercial vacuum simulators, to verify the advantages of VacCAD's efficiency. It was emphasized on immediacy and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and vacuum materials. First, usability of simulation mechanism was estimated through the modeling schematics and obtained simulation results of each employed simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping characteristics of commercially available high vacuum systems. In addition, the degree of tolerances on VacCAD was also investigated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacSim(Multi) has been presented, and it was expected that the utilization of VacCAD in vacuum applications to be increased.

Numerical Modeling of Floating Electrodes in a Plasma Processing System

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.24 no.4
    • /
    • pp.102-110
    • /
    • 2015
  • Fluid model based numerical analysis is done to simulate a plasma processing system with electrodes at floating potential. $V_f$ is a function of electron temperature, electron mass and ion mass. Commercial plasma fluid simulation softwares do not provide options for floating electrode boundary value condition. We developed a user subroutine in CFD-ACE+ and compared four different cases: grounded, dielectric, zero normal electric field and floating electric potential for a 2D-CCP (capacitively coupled plasma) with a ring electrode.