• 제목/요약/키워드: Vaneless Diffuser

검색결과 49건 처리시간 0.026초

Employing rotating vaneless diffuser to enhance the performance of plenum fan

  • Dou, Hua-Shu;Wu, Lin;Wei, Yikun;Chen, Yongning;Cao, Wenbin;Ying, Cunlie
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.9-18
    • /
    • 2017
  • Numerical simulation is carried out for flow characteristics in a plenum fan and the influence of the diameter ratio of the rotating vaneless diffuser on the performance of plenum fan is analyzed. The diameter ratio of the rotating vaneless diffuser employed is from 1.03 to 1.3. The research results show that the rotating vaneless diffuser is able to enhance the performance of plenum fan. It is found that there is significant improvement in static pressure and efficiency at the diameter ratio of 1.05 at high flow coefficients, while the optimal diameter ratio is 1.2 at rated and low flow coefficient.

원심형 송풍기에서 베인리스 디퓨저의 폭변화가 선회실속에 미치는 영향 (Effect of Diffuser Width on Rotating Stall in Centrifugal with Vaneless Diffuser)

  • 김진형;조강래
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1293-1302
    • /
    • 2001
  • It is generally known that radial vane blowers with vaneless diffuser may generate mostly only a rotating stall but backward curved vane blowers may do both an impeller and a diffuser rotating stalls. In this study, it was found from the numerical and experimental results that the diffuser rotating stall does not appear in a radial vane because of the suppression for the diffuser stall appearance by occurring of impeller rotating stall in a large flow rate coefficient. The diffuser rotating stalls occurring when the width of diffuser is broaden fur a backward curved vane blower are classified definitely by the diffuser flow rate coefficient defined by adopting the varying diffuser width.

Unsteady Flows Arising in a Mixed-Flow Vaneless Diffuser System

  • Tsurusaki, Hiromu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.92-100
    • /
    • 2008
  • The main objective of this study was to clarify the origin of the unsteady flows arising in a mixed-flow vaneless diffuser system and also the effects of physical components of the system. The testing equipment consists of a straight tube, a swirl generator, and a mixed-flow vaneless diffuser. Pressure fluctuations of the flow through the tube and diffuser were measured by using a semiconductor-type pressure transducer and analyzed by an FFT analyzer. In the experiment, the velocity ratio (axial velocity/peripheral velocity) of the internal flow, and the geometric parameters of the diffuser were varied. Two kinds of unsteady flows were measured according to the combination of the components, and the origin of each unsteady flow was clarified. The fundamental frequencies of unsteady flows arose were examined by two-dimensional small perturbation analysis.

베인없는 디퓨저에서의 스톨 임계 유동각에 관한 연구 (Stall Critical Flow Angle in a Vaneless Diffuser of a Centrifugal Compressor)

  • 강정식;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.611-614
    • /
    • 2002
  • Rotating stall in vaneless diffusers of centrifugal compressor occurs in the diffuser wall due to flow separation at large inlet flow angle. For this reason, the critical inlet flow angles are suggested by several researchers. Beyond this critical angle, flow separates in the diffuser, and develops into rotating stall. This paper studied this critical flow angle. Rotating stall is measured through eight fast-response pressure transducers which are equally spaced around the circumference at the inlet and exit of a vaneless diffuser. Experiments are done from 20000rpm to 60000rpm for the diffuser stall. Two-cell structure which rotates at $6{\~}l0{\%}$ of impeller speed is fully developed at $20000{\~}40000rpm$, and three-cell structure which rotates at $7{\~}9{\%}$ of impeller speed is fully developed at $50000{\~}60000rpm$. This paper shows that the critical inlet flow angle is not constant but related with tip speed of impeller. As tip speed increases, so does the critical inlet flow angle.

  • PDF

소형 원심 압축기의 성능 향상을 위한 베인 없는 디퓨저와 볼류트 케이싱의 설계에 관한 연구 (A study on the vaneless diffuser and volute casing design for the improvement of small centrifugal compressors)

  • 조재필;백승윤;김성돈;안규복
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.3722-3730
    • /
    • 2015
  • 하수 처리용으로 사용되는 소형 원심 압축기의 베인 없는 디퓨져와 볼류트 케이싱의 성능 개선을 수행하였다. 기존의 두 모델은 임펠러가 동일하나, 베인 없는 디퓨져의 폭과 길이 및 볼류트 케이싱의 형상은 서로 다르다. 기존 모델에 대한 실험과 유동해석 결과를 바탕으로 베인 없는 디퓨져와 볼류트 케이싱의 설계를 변경하였다. 세 모델에 대한 연구 결과로부터, 볼류트 케이싱의 단면적 및 입구 반경 길이는 볼류트 혀와 베인 없는 디퓨져 및 임펠러와의 상호작용 강도에 영향을 주었고, 시스템 손실량에 변화를 나타내었다. 베인 없는 디퓨져 폭이 감소하면 임펠러의 효율은 증가했지만 디퓨져에서의 손실도 증가하였다. 결과적으로 개선된 모델의 효율이 설계 점에서 기존 대비 약 2.88%p 향상된 것이 유동해석 결과로 확인되었다.

Development of a Performance Prediction Method for Centrifugal Compressor Channel Diffusers

  • Kang, Jeong-Seek;Cho, Sung-Kook;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제16권8호
    • /
    • pp.1144-1153
    • /
    • 2002
  • A hybrid performance prediction method is proposed in the present study. A channel diffuser is divided into four subregions: vaneless space, semi-vaneless space, channel, and channel exit region. One-dimensional compressible core flow and boundary layer calculation of each region with an incidence loss model and empirical correlation of residuary pressure recovery coefficient of a channel predict the performance of diffusers. Three channel diffusers are designed and tested for validating the developed prediction method. The pressure distributions from an impeller exit to the channel diffuser exit are measured and discussed for various operating conditions from choke to nearly surge conditions. The strong non-uniform pressure distribution which is caused by impeller-diffuser interaction is obtained over the vaneless and semi-vaneless spaces. The predicted performance shows good agreement with the measured performance of diffusers at a design condition as well as at off-design conditions.

PIV측정에 의한 깃 없는 디퓨저에서의 유동특성 (The Flow Characteristics in a Vaneless Diffuser by PIV Measurements)

  • 윤지인;신유환;이윤표;김광호
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.45-50
    • /
    • 2012
  • The flow characteristics in a vaneless diffuser with a backswept radial impeller have been experimentally investigated according to the variation of discharge flow rate. Particle image velocimetry(PIV) system was applied to measure velocity fields with several operating conditions and on some diffuser horizontal planes. Pressure transducers were installed on hub wall of the diffuser in order to analyze the pressure fluctuations and their corresponding velocity fields. The results show that the location of the main flow center moves from the hub to the shroud side as the flow rate decreases, and the reverse flow is locally generated on the hub side.

2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동 (Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor)

  • 강경준;신유환;김광호;이윤표
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

반경류형 회전차를 가진 원심송풍기의 깃이 없는 디퓨저 내의 선회실속에 관한 실험적 연구 (An Experimental Study on the Rotating Stall in Vaneless Diffuser of Centrifugal Blower with Radial Type Impeller)

  • 김진형;조강래
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1247-1254
    • /
    • 1998
  • The vaneless diffusers are widely used in industrial centrifugal compressors which are required to operate within a wide flow range. When very high pressure gases are handled by centrifugal compressor. rotating stall is a serious problem because of the occurance of large aerodynamic exciting forces. Rotating stall mostly often occurs in the impellers but it can occur in vaneless diffusers as well. In this experimental study, the rotating stall in vaneless diffuser with radial type centrifugal impeller was measured by changing the flow rate with I-type, X-type hotwire. As the result, it was cleared which type of rotating stall of the impeller stall would occur and how many stall cells would appear relating with the flow rate. As the flow rate reduced, the propagation speed of rotating stall was reduced. But the stall cell number unchanged with respect to the flow rate.

Experimental Study on Surge Inception in a Centrifugal Compressor

  • Tamaki, Hideaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.409-417
    • /
    • 2009
  • An investigation of surge inception in a centrifugal compressor was done with measurements of steady and unsteady static pressure. Vaneless diffuser and vaned diffuser were tested. Analyses of the static pressure and the pressure fluctuation showed that stall at the impeller leading edge occurred at first, and then it extended to downstream. In case of the vaneless diffuser, deterioration of the pressure rise in the impeller triggered instability. For the vande diffuser, instability that was generated in the impeller propagated into the vaned diffuser, however the pressure recovery by the vaned diffuser made the operation of the compressor stable at low flow rate.