• Title/Summary/Keyword: Voice Meter

Search Result 7, Processing Time 0.025 seconds

The Effects of Vocal Loudness on Nasalance Measures of Normal Adults (음의 크기가 정상성인의 비음도에 미치는 영향)

  • Lee, Su-Jung;Ko, Do-Heung
    • Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.191-203
    • /
    • 2003
  • This study examined the effect of vocal loudness on nasalance measures, under the conditions of three sentence patterns (i.e., Oral sentences, Mixed sentences, Nasal sentences). The vocal loudness level was classified into soft voice (55 dB), medium voice (65 dB) and loud voice (75 dB). The participants in the present study were 30 normal adults (male: female =1:1). Kay's Nasometer 6200 was used to measure nasalance and Sound level meter was used to adjust the loudness level. The results of the present study are as follows. Firstly, the change in vocal loudness is in the following. In the Oral sentence stimuli, the loud voice for both male and female showed the highest nasalance degree, and the medium voice the lowest level. In the Mixed and Nasal sentence stimuli, however, male participants showed the highest degree of nasalance in the soft voice, and the lowest degree in the loud voice, and female showed the highest degree of nasalance in the soft voice and the lowest in the medium voice. Secondly, when each subject's nasalance scores were ranked in a ordered manner, noticeable tendency. Lowest nasalance score occurred in the loud voice and the highest nasalance score was recorded in the soft voice during participants' reading of the Nasal sentences. However, it was hard to find such pattern in the Oral sentences. It is assumed that velopharyngeal function could be related to these findings. Furthermore, the findings associated with vocal loudness may have diagnostic as well as clinical implications.

  • PDF

Understanding of the Western Classical Singing in Medical Point of View (서양식 성악발성법의 의학적 이해)

  • Choi, Hong-Shik;Hong, Hyun-Jun;Yum, Yong-Hyuk;Nam, Do-Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.106-110
    • /
    • 2011
  • Western classical singing voices are different from those of pop song singer's singing voices as well as traditional Korean singing such as Pansori. We anlalysed the singing voices from three different categories with using free application programs available at the usual smart phones : sound level meter and Spectral View Analyzer and fiberoptic rhinolaryngoscopic evaluation. The intensity of voice produced by a classical western singer was 11 dB louder than that produced by a pop song singer. Source sound, glottic sound, as well as harmonic sound and singing resonant sound (Singer's formant) are much more prominent. When evaluated under video-rhinolaryngoscopy during singing, the resonance cavity especially oropharyngeal cavity and hypopharyngeal cavity are widely opened during singing of the western classical singer than those of the traditional Korean singer's singing. Difference of singing methods including producing the glottal sound, respiration and resonance are discussed. Possible explanation of development of 'Singer's Formant' is discussed.

  • PDF

Time Slot Exchange Protocol in a Reservation Based MAC for MANET

  • Koirala, Mamata;Ji, Qi;Choi, Jae-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.181-185
    • /
    • 2009
  • Recently, much attention to a self-organizing mobile ad-hoc network is escalating along with progressive deployment of wireless networks in our everyday life. Being readily deployable, the MANET (mobile ad hoc network) can find its applications to emergency medical service, customized calling service, group-based communications, and military purposes. In this paper we investigate a time slot exchange problem found in the time slot based MAC, that is designed for IEEE 802.11b interfaces composing a MANET. The paper provides a method to maintain the quality of voice call by providing a new time slot when the channel assigned for that time slot gets noisy with interferences induced from other nodes, which belong to the same and/or other subgroups. In order to assess the performance of the proposed algorithm, a set of simulations using the OPNET modeler has been performed assuming that the IEEE 802.11b interfaces are operating under a modified MAC, which is a time slot based reservation MAC implemented in the PCF part of the superframe. In a real-time voice call service over a MANET of a size 500 ${\times}$ 500 meter squares with the number of nodes up to 100, the simulation results are collected and analyzed with respect to the packet loss rate and packet delay. The results show us that the proposed time slot exchange protocol improves the quality of voice call over that of plain DCF.

  • PDF

Development of A Voice Recognition Multipurpose Meter for Blind People (시각장애인을 위한 음성인식 다용도 계량기 개발)

  • Bok Seonmin;Song Cheayeon;Jung Gyeongju;Jo Sunhang;Kim Seounghwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.994-995
    • /
    • 2023
  • 일상생활에서도 불편함을 겪는 시각 장애인들을 위해 기초적인 생활을 보완할 수 있는 음성인식 다용도 계량기를 개발하고자 하였다. 본 제품은 API를 통해 저울의 측정값을 한국어 음성으로 변환하여 출력하는 음성 저울과 음성인식을 통해 슬라이드 포트로 정수기를 제어하는 작동 기기로 구성되어 있다. 현재 음성인식 다용도 계량기 개발을 완료했으며, Web, APP 등의 개선 방안을 연구 및 적용하는 중에 있다. 본 계량기를 통하여 시각장애인·시력저하자의 일상생활 및 삶의 질 향상뿐만 아니라 병원 등의 공공시설 개선에도 도움을 줄 수 있을 것으로 기대된다.

Effects of Chest Compression Quality between Rescuer's Simplified Verbal-Order Method and Continued Verbal-Order Method during Cardiopulmonary Resuscitation (심폐소생술 시 구조자의 간소화된 구령방법과 연속된 구령방법 간의 가슴압박 질 효과)

  • Baek, Hong-Seok;Park, Sang-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.320-330
    • /
    • 2013
  • The purpose of this study is to increase efficiency of CPR through comparing the chest-compression quality between rescuer's simplified verbal order method and the continued verbal order method by utilizing voice meter during CPR. Subjects were 89 people(45 people for the experimental group, 44 people for the control group) who completed the 15-week CPR curriculum as undergraduates for the department of Emergency Medical Technology in C Province and were carried out by being randomly extracted. The group division was set for the experimental group as the group with the simplified verbal order and for the control group as the group with the continued verbal order. The period of measurement was progressed primarily(November 10, November 28, 2011) and secondarily(September 3-September 4, 2012). An analysis was used SPSS WIN 12.0 program. As a result of research, as for the implementation of appropriate chest compression(time, %), the quality was higher(p<.05) in the experimental group(102.86 times, 67.79%) than the control group(85.31 times, 55.84%). As a result of research, the chest compression(time, %) in the experimental group(102.86 times, 67.79%) had the higher effect of chest compression quality(p<.05) than the control group(85.31 times, 55.84%). On the other hand, the operation of weak chest compression(time) was higher in control group(61.13 times) than experimental group(35.54 times). The proper chest compression was shown(p<.05) in men of the experimental group as for gender and in over 60kg of the experimental group as for weight.

The Design and Performance Test of Miniaturized Sled Type Dual-Servo Actuator (초소형 Sled-type 이중 서보 엑추에이터 설계 및 특성 분석)

  • 강동우;김기현;정재화;권대갑
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.357-360
    • /
    • 2002
  • Nowadays, the improvement and development of Multi-media, information and communication technology are rapidly processed. And many products, for example, digital camera, digital camcorder, and PDA, are used for them. They need large data storage capacity and small size, light storage system. Due to that, many studies and researches in data storage system have been carried out. Especially, micro drive system was presented by IBM.(1) However, its system is expensive and uneasy to be portable. In ODD technologies, 1 inch drive system is not yet or in processing status.(2) If to be possible and to be come up, it is cheap than HDD system and easy to transfer information. In this paper, a miniaturized actuator(about linch) is designed and tested for ODD system. Specially, it is adapted for NFR(Near-field Recoding) system using SIL(Solid Immersion Lens). It is the dual-servo actuator which consists of a coarse actuator and fine actuator. Its actuating force generation method is VCM(Voice Ceil Motor). The fine actuator has 4-wire suspensions and bobbin wrapped by coil and includes focusing motion as well as tracking motion. The coarse actuator has an actuating coil and V-grooved guide mechanism. Also, the characteristics of the designed actuator is estimated by sine-swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF

The Design and Performance Test of Tracking Actuator for NFR system (근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험)

  • Kim, Gi-Hyeon;Lee, Mun-Gu;Gwon, Dae-Gap
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.174-181
    • /
    • 2001
  • Nowadays, the improvement and development of Multi-media and information & communication technology is rapidly processed. They need large data storage capacity. So that, many studies and researches in data storage have been carried out. According to them, the data storage capacity has been increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size are covered by new data storage methods-- for examples, AFM(Atomic Force Microscopy), MO(Magneto-optical) system, and NFR(Near-Field decoding) system etc. But the resolution limit of an actuator was not developed and doesn\`t follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator if studied and designed for NFR (in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator. and should desire 100nm accuracy. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings. Also, The Characteristics of designed actuator for NFR system is estimated by Sine-Swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF