• 제목/요약/키워드: Volume Curve

검색결과 658건 처리시간 0.032초

5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구 (A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

강원도 지방 소나무의 지역(地域) 간곡선(幹曲線) 및 재적식(材積式) 모델 (Regional Stem Curve and Volume Function Model of Pinus densiflora in Kangwon-Province)

  • 김준순;이우균;변우혁
    • 한국산림과학회지
    • /
    • 제83권4호
    • /
    • pp.521-530
    • /
    • 1994
  • 재적식(材積式)은 보통 흉고직경과 수고의 함수로 표현되는데, 회귀분석(回歸分析)을 통해 정확도가 높은 식이 주로 채택되고 있다. 우리나라에서도 지금까지 흉고직경(D)과 수고(H)를 독립변수로 하는 지수식(指數式)($V=aD^bH^c$)으로 각 수종에 대한 일반(一般)재적식을 유도하고 있다. 본 연구에서는 강원도 지방내의 홍천, 정선, 명주, 원주, 영월지역에 대한 간곡선식(幹曲線式)을 지역별로 유도하고, 이 간곡선식의 회전체(回轉體) 적분(積分)을 통해 지역별 재적을 직접 추정할 수 있는 간곡선 및 재적식 모델을 마련하였다. 조제된 모델에 의해 지역별로 추정된 재적은 기존의 강원도 지방 소나무재적표에 의해 추정된 재적에 비해 정확도가 높았다. 또한 지역간곡선식에 의해 유도된 간곡선의 형태는 지역에 따라 서로 달랐으며, 특히 영월지역과 원주지역의 수간은 다른 지역에 비해 수간상부에서 가늘게 발달하는 것으로 나타났다. 이와같은 간곡선의 다양한 형태는 재적추정에 있어서도 지역간 차이를 유발하였다.

  • PDF

신체지표와 유량-기량곡선 지표간의 상관성 (Correlations between Body Indices and Flow-Volume Curve Parameters)

  • 진복희
    • 대한임상검사과학회지
    • /
    • 제41권3호
    • /
    • pp.135-139
    • /
    • 2009
  • Pulmonary function test has been know to be greatly affected by body indices, such as sex, age, height, body weight, body surface area (BSA) and body mass index (BMI), so hat this study was focused to see the relationship between body index and flow-volume curves. Subjects were 156 (male 90, female 66) and they were examined for pulmonary function test in terms of body index and correlation/multiple regression analysis of flow-volume curves at Presbyterian Medical Center from March to August, 2009. The followings results after analyzing the correlation between body index and flow-volume curves. Although flow-volume curve FEF25-75% showed close correlation with age, body weight, and body surface area, but not with body mass index. In addition, multiple regression analysis was performed to see how each body index affects flow-volume curve FEF25-75%, and FEF25-75% dispersion was explained as 74.5% with age only, 94.2% with age and height, and 96% with age, height, and sex. Therefore, sex, age and height that are mainly used for predictive formular of pulmonary function test and nomogram were important factors for pulmonary function test itself, and further study must be done for other body index.

  • PDF

현장 함수비 모니터링과 습윤-건조 함수특성곡선을 이용한 산사태 취약성 분석 (Landslide Analysis Using the Wetting-Drying Process-Based Soil-Water Characteristic Curve and Field Monitoring Data)

  • 이성철;홍문현;정상섬
    • 한국지반공학회논문집
    • /
    • 제39권5호
    • /
    • pp.13-26
    • /
    • 2023
  • 불포화토의 함수특성곡선은 산사태 평가와 토석류 분석에 매우 중요한 요소이다. 본 연구에서는 현장에 적합한 모관흡수력을 통해 산사태 취약성을 분석하기 위하여 함수특성곡선과 체적변형을 고려한 수축시험을 수행하였다. 실험에 사용된 시료는 국내에 분포하는 세립분이 다량함유된 SM계열 화강 풍화토이며, 산사태 해석 시 사용된 강수량의 경우 실측된 데이터를 사용하였다. 실내실험 시 측정된 함수특성곡선은 건조과정에서 발생 된 곡선이며, 체적변형 확인할 수 있는 수축시험을 통하여 습윤과정에서 발생되는 곡선을 재 산정하여 산사태 취약성 분석을 하였다. 본 연구결과 습윤곡선의 안전율이 건조곡선의 안전율보다 낮게 나타남을 알 수 있었으며 그 결과 현장 사면지반의 체적변형을 고려한 모관흡수력 산정이 필요함을 확인 하였다.

Adaptive B-spline volume representation of measured BRDF data for photorealistic rendering

  • Park, Hyungjun;Lee, Joo-Haeng
    • Journal of Computational Design and Engineering
    • /
    • 제2권1호
    • /
    • pp.1-15
    • /
    • 2015
  • Measured bidirectional reflectance distribution function (BRDF) data have been used to represent complex interaction between lights and surface materials for photorealistic rendering. However, their massive size makes it hard to adopt them in practical rendering applications. In this paper, we propose an adaptive method for B-spline volume representation of measured BRDF data. It basically performs approximate B-spline volume lofting, which decomposes the problem into three sub-problems of multiple B-spline curve fitting along u-, v-, and w-parametric directions. Especially, it makes the efficient use of knots in the multiple B-spline curve fitting and thereby accomplishes adaptive knot placement along each parametric direction of a resulting B-spline volume. The proposed method is quite useful to realize efficient data reduction while smoothing out the noises and keeping the overall features of BRDF data well. By applying the B-spline volume models of real materials for rendering, we show that the B-spline volume models are effective in preserving the features of material appearance and are suitable for representing BRDF data.

녹색 신교통 시스템 바이모달트램의 비용-수요 공급곡선을 고려한 도시 대중교통체계 적용 특성 분석 (Analysis of Applicability in the Public Transportation System considering the Cost-volume Supply Curve of New Transit System Bi-Modal Tram)

  • 김홍석;김량균;함재현;전재청;윤희택
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2303-2308
    • /
    • 2010
  • We studied the cost-volume supply characteristic of public transportation systems focused on Bi-modal Tram in the main cities to analyze the applicability and status for the new transit system Bi-modal Tram as public transportation system. The operation cost considering the characteristic of vehicle, facilities, operation and average cost for respective public transportation system and the time cost considering the travel and transfer time are defined to the social cost, and the cost-volume supply curve is based on this social cost. The cost-volume supply characteristic between public transportation modes in the city is determined on the basis of cost-volume supply curve. Through the comparison between cost-volume supply characteristic of main transportation systems, it is analyzed about the relation between public transportation systems in the city and the characteristic for proper service provision. The application of Bi-modal Tram in the city is concluded that it is effective to reduce the social cost on the existing public transportation system.

  • PDF

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제9권2호
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

Ti-10V-2Fe-3Al 합금의 응력-변형거동 계산 (The calculation of stress-strain behavior of Ti-10V-2Fe-3Al alloys)

  • 오택열
    • 오토저널
    • /
    • 제11권6호
    • /
    • pp.38-47
    • /
    • 1989
  • The Finite Element Method has been employed to calculate the effect of particle size, matrix, and volume fractions on the stress-strain relations of .alpha.-.betha. titanium alloys. It was found that for a given volume fraction, the calculated stress-strain curve was higher for a finer particle size than for a coarse particle size within the range of the strains considered, and this behavior was seen for all the different volume fraction alloys considered. The calculated stress-strain curves for three vol. pct .alpha. alloys were compared with their corresponding experimental curve, and in general, good agreement was found.

  • PDF

강제환기식 돈사의 환기량 추정을 위한 회귀모델의 비교 (Comparison of Regression Models for Estimating Ventilation Rate of Mechanically Ventilated Swine Farm)

  • 조광곤;하태환;윤상후;장유나;정민웅
    • 한국농공학회논문집
    • /
    • 제62권1호
    • /
    • pp.61-70
    • /
    • 2020
  • To estimate the ventilation volume of mechanically ventilated swine farms, various regression models were applied, and errors were compared to select the regression model that can best simulate actual data. Linear regression, linear spline, polynomial regression (degrees 2 and 3), logistic curve, generalized additive model (GAM), and gompertz curve were compared. Overfitting models were excluded even when the error rate was small. The evaluation criteria were root mean square error (RMSE) and mean absolute percentage error (MAPE). The evaluation results indicated that degree 3 exhibited the lowest error rate; however, an overestimation contradiction was observed in a certain section. The logistic curve was the most stable and superior to all the models. In the estimation of ventilation volume by all of the models, the estimated ventilation volume of the logistic curve was the smallest except for the model with a large error rate and the overestimated model.

Accuracy of maximal expiratory flow-volume curve curvilinearity and fractional exhaled nitric oxide for detection of children with atopic asthma

  • Park, Sang Hoo;Im, Min Ji;Eom, Sang-Yong;Hahn, Youn-Soo
    • Clinical and Experimental Pediatrics
    • /
    • 제60권9호
    • /
    • pp.290-295
    • /
    • 2017
  • Purpose: Airway pathology in children with atopic asthma can be reflected by the concave shape of the maximal expiratory flow-volume (MEFV) curve and high fractional exhaled nitric oxide (FeNO) values. We evaluated the capacity of the curvilinearity of the MEFV curve, FeNO, and their combination to distinguish subjects with atopic asthma from healthy individuals. Methods: FeNO and angle ${\beta}$, which characterizes the general configuration of the MEFV curve, were determined in 119 steroid-naïve individuals with atopic asthma aged 8 to 16 years, and in 92 age-matched healthy controls. Receiver operating characteristic (ROC) curve analyses were performed to determine the cutoff points of FeNO and angle ${\beta}$ that provided the best combination of sensitivity and specificity for asthma detection. Results: Asthmatic patients had a significantly smaller angle ${\beta}$ and higher FeNO compared with healthy controls (both, P<0.001). For asthma detection, the best cutoff values of angle ${\beta}$ and FeNO were observed at $189.3^{\circ}$ and 22 parts per billion, respectively. The area under the ROC curve for the combination of angle ${\beta}$ and FeNO improved to 0.91 (95% confidence interval [CI], 0.87-0.95) from 0.80 (95% CI, 0.75-0.86; P<0.001) for angle ${\beta}$ alone and 0.86 (95% CI, 0.82-0.91; P=0.002) for FeNO alone. In addition, the combination enhanced sensitivity with no significant decrease in specificity. Conclusion: These data suggest that the combined use of the curvilinearity of the MEFV curve and FeNO is a useful tool to differentiate between children with and without atopic asthma.