Walk-by Meter Reading System of Digital Water Meter Based on Ubiquitous (유비쿼터스기반 디지털 수도미터 옥외검침시스템 개발)

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Young-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.7
    • /
    • pp.688-693
    • /
    • 2009
  • In terms of water meter reading, the majority of 16 million houses use mechanical water meter in korea. So, a member of the utility's staff needs to access periodically the water meter and the value of the metered volume. However, due to the use of mechanical water meter, many issues have been appeared as cost, time, errors, accessibility, and readability. To settle these issues, we developed the walk-by meter reading system of digital water meter and outside indicator based on ubiquitous. And we could get the characteristics and the economical efficiency for water meter reading system. Thus, this study shows that the system can be widely used to the block system and the meter reading system for stable water supply.

Design and Fabrication of Digital Water Meter Using a Variable Capacitor (가변 콘덴서를 이용한 디지털 수도미터의 설계 및 제작)

  • Park, Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • The AMR(automatic meter reading) system has been increasingly and widely used for its efficient and intelligent management, which is a technology that automatically collects consumption data from a water meter or energy metering device. The digital meter instead of the mechanical meter should be used in the system. Up to now, various types of sensor to measure the water flow rate have been used in the digital water meter, for example, reed switch, photo IR approximate sensor, ultrasonic sensor, electromagnetic sensor, etc. In this paper, a new sensing technology, where a variable capacitor and digital circuit were used for sensing the water flow rate, was proposed. The circuit was designed and verified by Pspice simulation. And a PCB board for the circuit was fabricated. After then, a prototype of digital water meter using a variable capacitor to measure the water flow rate was fabricated. The function tests of the fabricated digital water meter were performed, and it was found that the meter worked properly. Since the new technology has much better properties in terms of cost and power consumption compared to conventional technologies, it should be one of the major digital water meter technologies in the future.

A Study on Frost Protection Methods for Water Meter in Seoul Area (서울지역의 수도계량기 동파방지방안 연구)

  • Kim, H.I.;Ryu, T.H.;Park, T.J.;Oh, S.Y.;Choi, Y.J.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.612-617
    • /
    • 2007
  • Water meter frost in winter is a nuisance to the water administration and citizen as well. It causes stop of water supply, possibility of accident due to leakage freezing, and additional official work to change frost water meters. This study was carried out to give some basic information of water meter frost condition, to verify the effect of frost protection devices such as lagging vinyl cover, electric heater, and meter pit using subterranean heat. Nearly half of the number of the water meter frost happens in old apartment house with outer corridor, and temperature of the meter box was measured in that kind of apartment house, comparing with atmosphere temperature. The capability of three kinds of lagging vinyl cover was investigated by measuring the inside temperature of the insulated box. Also the capability of existing meter pits and new meter pits using subterranean heat was compared by measuring the inside temperature of the pits. One of the result is that the inside temperature of meter pits using subterranean heat was higher than that of the existing ones, and deeper pit causes higher inside temperature in case of using subterranean heat.

  • PDF

Development of replacement priority by analysis of effect of water meter replacement (수도미터 교체 우선순위 선정기준 개발)

  • Son, Dong-Wan;Kim, Dong-Hong;Lee, Doo-Jin;Jung, Kwan-Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.509-516
    • /
    • 2014
  • This study describes a reasonable planning method for water meter replacement which can minimize the metering under-registration for an increasement of revenue water. The increment analysis of real water usage was used to establish a replacement plan. The meter replacement database collected from K City was used as the basis of this analysis. The database included 964 connections of domestic and non-domestic consumers that had their meter replaced by aging at 2011. The result showed that the corelation between unregistered water volume and water meter age was lower than commonly expected where the current criteria of replacement is only water meter age(8 years) excluding the meters older than 13 years. And in the analysis result of water usage for 8 years, the total amount and increment of water usage had a significant effect on unregistered water volume. However the relation was different tendency as a total volume and slope of increment. In case of total water volume was larger than 10,000, larger than 7,000 and increment of 0.0 ~ -0.3, larger than 6,000 and increment more than -0.3 were analysed to need a replacement because of metering under-registration.

Wireless Digital Water Meter with Low Power Consumption for Automatic Meter Reading (원격검침을 위한 저 전력 무선 디지털 수도계량기)

  • Lee, Young-Woo;Oh, Seung-Hyueb
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.963-970
    • /
    • 2008
  • Recently, several papers for reading meters remotely using RFID/USN technologies have been presented. In the case of water meter, there has been neither commercial product nor paper. In this paper, we describe the design and implementation of wireless digital water meter with low power consumption. We use magnetic hole sensors to compute the amount of water consumption. The meter of water consumption is transferred via ZigBee wireless protocol to a gateway. Low power consumption design is essential since a battery should last till the life time of water meter. We present that dual batteries haying 3V, 3000mAh, would last 8 years by analyzing the real power consumption of our water meter.

Automatic Meter Reading System for Water-Supply (상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로)

  • Seo, Chang-Gab;Park, Young-Jae
    • Journal of Digital Convergence
    • /
    • v.7 no.3
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis (구조해석 기반 동결팽창압 흡수용 수도미터 개발)

  • Kim, Kuk-il;An, Sang-byung;Lee, Byung-sun;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.314-316
    • /
    • 2022
  • Instrumentation device to the amount of water used by the user is a water meter by measuring management stability is necessary. But with the onset of winter to meter water was ice inside the phase change and about 9 % and increase the volume of the meter is damaged. The existing protection bleed water meter freeze protection technology into three great bootong, supplying the heat insulation inside the external protection, water metering for water meter in the freeze protection will be divided into installing the device. Not see how far the structure for the commercialization of new technology-based products and aims to develop technologies that do not require an external power supply. Thus, freeze more vulnerable by internal pressure of the interpretation applied to a water meter in temperatures below zero internal pressure to confirm the area of preventing damage and freeze protection that can reduce the effect is superior to develop a water meter.

  • PDF

Effects of Nozzle Diameter on Performance Characteristics for a Tangential Impeller-type Water Meter (접선류 임펠러형 수도미터의 노즐직경이 성능특성에 미치는 영향)

  • Suh, Sang-Ho;Lee, Byung-Ho;Cho, Min-Tae;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.59-66
    • /
    • 1999
  • In this study the effects of nozzle diameter on the performance characteristics for the tangential impeller-type water meter are studied experimentally. The nozzle is cut along the tangential direction of the inner case in the water meter. The nozzle shape is round and the number of nozzles used for the experimental study are 8. The performance characteristics are discussed for various nozzle diameters such as 3.1, 3.3, 3.5, 4.0, 4.5 and 5.0 mm. Among the tangential impeller-type water meters, the water meter with the nozzle diameter of 5.0 mm shows the least pressure loss and the instrumental error compared to the Korean Standards.

  • PDF

A Study for the Improvement of Performance of the Water-meter applying the Hydrodynamic Journal Bearing Theory (동압 유체 베어링 이론을 적용한 수도미터의 성능향상에 관한 연구)

  • Yoon, Joon-Yong;Sung, Nak-Won;Kim, Byung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.1 s.6
    • /
    • pp.5-9
    • /
    • 2000
  • A study to minimize the error in water-meter is considered in this work. It is presumed that the large amount of error at large flowrate is occurred due to the vibration of the impeller shalt. After a newly designed bushing applying hydrodynamic journal bearing theory is adopted, the error at large flow rate is decreased remarkably comparing with the classical water-meter. It is concluded that the effect of a bushing in water-meter stabilizes the rotator of the impeller shaft.

  • PDF

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.