• Title/Summary/Keyword: Water absorption

Search Result 3,229, Processing Time 0.034 seconds

A experimental study of water vapor absorption characteristics using four components solution for gas fired absorption chiller (가스냉난방기용 4성분계 흡수용액의 수증기 흡수특성에 관한 실험적 연구)

  • Lee Yong-Won;Oh Young-Sam;Park Dal-Ryung;Baek Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.47-52
    • /
    • 1998
  • Water vapor absorption performance of four components solution ($LiBr+LiNO_3+LiC1+H_2O$) which could be substituted for commonly used $LiBr/H_2O$ solution in water cooled abosorption chiller is tested using a vertical tube absorber. Inlet solution concentration, inlet solution temperature, solution flow rate and inlet temperature of cooling water is varied as experimental parameters. The results of the experiment of water vapor absorption performance show that four components solution should have $2\%$ higher concentration for equal absorption capacity of $LiBr/H_2O$. But considering that four components solution have higher solubility than LiBr solution about $3\%$ high oncentration, four components solution ($LiBr+LiNO_3+LiC1+H_2O$) have more absorption capacity than LiBr solution in actual absorption chiller and can be applied to a small or air cooled absorption chiller.

  • PDF

The Comparison of Absorption Characteristics between High Absorbent Polymers and Cellulose (고흡수성(高吸水性) Polymer와 Cellulose의 흡수특성(吸水特性) 비교(比較))

  • Yang, In;Ahn, Won-Yung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.36-48
    • /
    • 1990
  • This experiment was carried out to improve the quality of high absorbent polymer which has excellent absorptivity and water retention compared to pulp and absorption sheet, through absorption characteristics-absorptive power, water retention, absorption rate, gel strength, pH, particle size, and moisture content. - of six polymers, namely, anionic polyacrylamide, cationic polyacrylamide, polyacrylic, acid polyvinyle alcohol 500, and 1500, and a-cellulose. and to examine the possibility of substitution of amide groups for carboxyl group and/or hydroxyl group which were commercial high absorbent polymer by comparing the absorption characteristics of the polymers. Polyacrylamide has high absorptive power and water retention, but has low gel strength and poor absorption rate. The rest of polymers were similiar to ${\alpha}$-cellulose in every respect. Thus, polyacrylamides could be replaced with polyacrylic acid and polyvinyl alcohol which are presently a high absorbent polymers. In comparing the absorption characteristics and the absorptive power of the polymers-anionic polyacrylamide, cationic polyacrylamide, polyacrylic acid, polyvinyle alcohol. a-cellulose-the absorptive power was in inverse proportion to the gel strength and absorption rates, affected by the particle size and pH change.

  • PDF

Physical Properties of Agro-Flour Filled Aliphatic Thermoplastic Polyester Bio-Composites

  • Eom, Young Geun;Kim, Hee Soo;Yang, Han Seung;Kim, Hyun Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.71-78
    • /
    • 2004
  • The purpose of this study was to investigate the water absorption and thickness swelling of biocomposites at room temperature. These properties of bio-composites mainly depend on the ability of the agro-flour to absorb water through hydrogen bonding between water and the hydroxyl groups of the holocellulose and lignin in the cell wall. As the content of agro-flour increased, the water absorption and thickness swelling of the bio-composites increased. The effects of agro-flour content and rice husk flour (RHF) particle size on the water absorption and thickness swelling of the bio-composites were evaluated. In general, wood-based materials showed significantly higher water absorption and thickness swelling than the bio-composites. This might be attributed to the ability of the polybutylene succinate (PBS) hydrophobic polymer to prohibit the water absorption and thickness swelling of the bio-composites, Therefore, the use of agro-flour filled PBS bio-composites, which exhibit improved dimensional stability in comparison with wood-based materials, is recommended.

Cycle Analysis of Hot Water Driven Absorption Refrigerator with New Working Absorption Solution (신흡수용액을 이용한 중온수 흡수식 냉동기의 사이클 해석)

  • Gwon, O-Gyeong;Yun, Jae-Ho;Mun, Chun-Geun;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1241-1248
    • /
    • 2002
  • Performance extension of the absorption refrigerator with LiBr solution is often faced to operate very close to the crystallization limit. Especially in the development of an air-cooled cycle, the crystallization of working solution in the system is a very difficult problem to overcome. This paper describes the cycle of hot water driven absorption system using a new working absorption solution instead of LiBr solution to improve the efficiency. In this study, we found out the characteristics of new working absorption solution through the cycle simulation and compared LiBr solution to evaluate. The effect of cooling water temperature, weak solution flow rate, hot water temperature and hot water flow rate were also examined. The COP is increased 22% higher in the case of LiBr+Li1+LiC1+LiNO$_3$$H_2O$, 2% LiBr+HO(CH$_2$)$_3$OH+$H_2O$ than that of LiBr solution for the same operation condition.

Effect of a non-absorbable gag on the absorption process in a vortical tube absorber (수직원관형 흡수기의 흡수과정에 미치는 비흡수가스의 영향)

  • 허기준;정은수;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.456-465
    • /
    • 1998
  • Effect of a non-absorbable gas on the absorption process in a vertical tube absorber was investigated numerically. The water vapor mined with air as the non-absorbable gas is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. It was shown that the local absorption rate decreases as the mass fraction of air in water vapor increases. The vapor pressure of water at the liquid-vapor interface reduces significantly since the non-absorbable gas is accumulated near the interface. The effect of non-absorbable gases on absorption rate becomes larger as the mass flow rate of the vapor decreases. For small amount of non-absorbable gases the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. Total absorption rate increases as the mass flow rate of the vapor increases for large concentration of non-absorbables at the inlet of an absorber.

  • PDF

Effects of a Non-absorbable Gas on the Absorption Process in a Vertical Tube Absorber

  • Hur, ki-Joon;Jeong, Eun-Soo;Jeong, Si-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.69-78
    • /
    • 1999
  • Effects of a non-absorbable gas on the absorption process in a vertical tube absorber has been investigated numerically. The water vapor mixed with air is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. The local absorption rate has been shown to decrease as the mass fraction of air in the water vapor increases. The vapor pressure of water at the liquid-vapor is interface reduced significantly since the non-absorbable gas accumulates near the interface. The effects of non-absorbable gases on absorption rate become larger as the mass flow rate of the vapor decreases. For a small amount of non-absorbable gases, the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. The total absorption rate increases as the mass flow rate of the vapor increases for large concentrations of non-absorbable gases at the inlet of an absorber.

  • PDF

Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance (크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun;Lee, Rae-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.

A study on the new absorption material for anechoic water tank (무향수조를 위한 흡음재질에 관한 연구)

  • Kim, Sung-Boo;Lee, Jong-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.2
    • /
    • pp.174-179
    • /
    • 2012
  • A new absorption material, cellulose sponge soaked in cement, was made for anechoic water tank and its acoustical properties were investigated by pulse methods. The sound absorption coefficient a (dB/cm) of the material was obtained in the frequency range of 40~120kHz from the echo reduction ER (dB) and insertion loss IL (dB) data. The result was averagely 1.8dB/cm higher than the sound absorption coefficient a (dB/cm) of cork-filled rubber which is one of the most effective absorption materials. The wedge (1.2~5.0cm long) type absorption tiles were made with this new material. The echo reduction ER (dB) of the absorption tile with 5.0cm wedge measured in water tank was higher than 20dB in the experimental frequency range.

Changes in Water Absorption, Water-holding Capacity, Chromaticity and Mineral Contents of Dried Sea Mustards on Soaking (건미역의 수침에 따른 흡수율과 보수율, 색도 및 무기성분의 함량 변화)

  • ;;;南出隆久
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.11 no.3
    • /
    • pp.209-218
    • /
    • 2001
  • This study was conducted to examine the water absorption, water-holding capacity, color and mineral contents in natural and cultured dried sea mustards on soaking treatment. Four dried samples of natural and cultured sea mustards were used for the experiments. The effects of soaking treatment on water absorption and water-holding capacity in sea mustards were examined, as the results, these were rapidly accelerated 5 minutes after soaking. It showed that water-holding capacity was significantly high in the case of high absorption of water by soaking. The L, a and b values were increased until 30 minutes after soaking. There was significant difference for potassium content between dried natural and dried cultured sea mustards and the natural sea mustard was 10 times as high as the cultured sample. All mineral elements in these materials were significantly decreased and especially, potassium were significantly more decreased at 50~80% of total content by soaking treatment. Ca/ P ratio in these materials by soaking was about 2~3 : 1 levels.

  • PDF

Water Absorption Characteristics of Substrate with Physical Properties of wick in Subirrigation System Using wick (심지형 저면관수시스템의 심지의 물리적 성질에 따른 수분흡수 특성)

  • Dong Ho Jung;Jung Eek Son
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.41-42
    • /
    • 2001
  • The objectives of this study were to investigate the effect of the physical properties of wick on the water absorption of substrate. Physical properties of wick in this study were cotton composition, width and length. The water Infiltration rate through the wick was 0.24 ㎝/s at 90 -95% cotton content, which was faster than at 80-85% (0.13 cm/s) and 70-75% (0.08 cm/s). As the cotton content increased, the water absorption of substrate became greater : the amount of absorbed water was about 5-7g higher at 90-95% than at 80-85% and 70-75% at a wick width of 1 ㎝, the velocity of water absorption through the wick was fastest with 0.25 ㎝ㆍs/sup -1/. The amount of absorbed water was higher at 3 ㎝ than at 1 and 2 ㎝. However, the water absorption rate through the cross - sectional area of wick (g H₂O /㎠/hr) was higher at a wick width of 2 ㎝ than at those of 1 and 3 ㎝. The amount of absorbed water in the substrate was higher at 2 : 1 than at 1 : 1 (length in substrate : length out of substrate). Absorbed water amount was larger at 30-40% initial moisture content than any other treatment.

  • PDF