• Title/Summary/Keyword: Wave-shaping

Search Result 58, Processing Time 0.035 seconds

A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals

  • Yoo, Young-Sil;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.220-227
    • /
    • 2012
  • Objectives: The study was to compare the shaping ability of Reciproc (VDW) and WaveOne (Dentsply Maillefer) instruments compared with ProTaper, Profile and hand instrument during the preparation of simulated root canals. Materials and Methods: Five groups (n = 5) were established. Reciproc, WaveOne, ProTaper, Profile and K file (K-flexo file) were used to prepare the resin simulated canals. A series of preoperative and postoperative images were taken by a microscope and superimposed in 2 different layers. The amount of resin removed from both the inner and the outer sides of the canal was measured to the level of 10 mm from the apical tip, with a 1 mm increment. Results: The mean of resin removal from the inner canal wall was not different from the outer canal wall for Reciproc and WaveOne groups at apical third (1 - 3 mm level). There was no difference in the change of working length and maintenance of canal curvature. NiTi instruments are superior to stainless-steel K file in their shaping ability. Conclusions: Within the limitation of this present study, Reciproc and WaveOne instruments maintained the original canal curvature in curved canals better than ProTaper and Profile, which tend to transport towards the outer canal wall of the curve in the apical part of the canal.

Ultrasonic Detection of Cracks in Studs and Bolts Using Dynamic Predictive Deconvolution and Wave Shaping

  • Suh, Dong-Man;Kim, Whan-Woo;Kim, Dae-Yen;Chung, Jin-Gyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1E
    • /
    • pp.44-53
    • /
    • 1998
  • Bolt degradation has become a major issue in the nuclear industry since the 1980's due to failure during operation. If small cracks in stud bolt are not detected early enough, they grow rapidly and cause catastrophic disasters. Their detection, despite its importance, is known to be a very difficult problem due to the complicated structures of the stud bolts. This paper presents a method of detecting and sizing a small crack in the root between two adjacent crests in threads. The key idea is from the fact that the Rayleigh wave propagates slowly along a crack from the tip to the opening and is reflected from the opening mouth. When there exists a crack, a small delayed pulse due to the Rayleigh wave is detected between large regularly spaced pulses from the thread. The delay time is the same as the propagation delay time of the slow Rayleigh wave and is proportional to the size of the crack. To efficiently detect the slow Rayleigh wave, three methods based on digital signal processing are proposed : modified wave shaping, dynamic predictive deconvolution, and dynamic predictive deconvolution combined with wave shaping.

  • PDF

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

Comparison of the shaping ability of novel thermally treated reciprocating instruments

  • Keskin, Cangul;Demiral, Murat;Sariyilmaz, Evren
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.15.1-15.7
    • /
    • 2018
  • Objectives: The present study aimed to evaluate the shaping ability of 2 thermally treated nickel-titanium reciprocating systems in simulated curved canals. Materials and Methods: Forty simulated canals were prepared to apical size 25 using Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply Sirona) instruments. Standard pre- and post-preparation images were taken and superimposed. The removal of resin material was measured at 5 standard points: the canal orifice, halfway between the canal orifice and the beginning of the curve, the beginning of the curve, the apex of the curve, and the end-point of the simulated canal. The data were analysed using the independent sample t-test with a 5% significance threshold. Results: The canals in which Reciproc Blue R25 was used showed a significantly greater widening than those in which WaveOne Gold was used at 4 of the 5 measurement points (p < 0.05). The Reciproc Blue R25 instrument removed significantly more resin from the inner aspect of the curve at 2 of the 5 points and similar amounts at the remaining 3 points. At the 2 apical points, there was no significant difference between the Reciproc Blue R25 and WaveOne Gold Primary instruments. Conclusion: Both instruments respected the original canal anatomy; however, WaveOne Gold resulted in a more conservative shape with less transportation.

Musical Tone Synthesis using Nonlinear Distortion Method (비선형 왜곡법을 이용한 악기음의 합성)

  • Lee Duck-Soo;Sung Keong-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.5
    • /
    • pp.33-50
    • /
    • 1989
  • In this paper, musical tone, especially instrument tones are synthesized using nonlinear distortion technique. Nonlinear distortion is very simple but versatile method when you synthesize musical instrument tones. It basically consists of one sine oscillator and amplifier which makes distortion to Input wave. Output wave has many harmonics that can be controlled by varying shaping function, which is the transfer function of nonlinear amplifier. Shaping function Is obtained from the analyzed harmonic amplitude data. Given harmonics amplitudes, Chebyshev polynomial is used to produce the shaping function that exactly makes the given harmonics at steady state. We contructed non -real time nonlinear distortion synthesizer program running at IBM-PC. To quantify the satis faction of synthesised tones, listening test is carried out, and the result is presented.

  • PDF

A New Unity Power Factor Rectifier System using an Active Waveshaping Technique

  • Choi, Se-Wan;Bae, Young-Sang
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • This paper proposes a new three-phase diode rectifier system with a sinusoidal input current at unity power factor and a regulated and isolated output voltage at low level. The inherent natural wave-shaping capability of the reduced kVA polyphase transformer together with an active current wave-shaping technique results in a significant reduction of input and output filter requirements associated with switching ripple and EMI. The operation principles are described along with a design example and a comparative evaluation. Experimental results on a 1.5kW prototype are provided to validate the proposed concept.

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.

Computer-Aided Optimal Design of Electronic Systems (전자계산기에 의한 전자기기의 최적 설계방식연구)

  • Kim, Deok-Jin;Park, In-Gap;Kim, Seon-Yeong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.6
    • /
    • pp.21-30
    • /
    • 1975
  • A method by which one can optimize the complex responses of electronic circuits has been suggested. represented in the complex forms, the optimization methods presented so far have dealt with real magnitude and phase responses of circuits. Design examples are shown on the optimal designs of an amplifier, filter, operational circuits transmission lines. and a wave-shaping circuit.

  • PDF

Photorefractive two-wave coupling properties of time-modulated optical signal in Cu-KNSBN crystal and its applications (Cu-KNSBN 결정에서 시변조된 광신호의 광굴절 2광파결합 특성 및 응용)

  • 소지영;이권연
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.104-110
    • /
    • 1998
  • The energy transfer between two incident beams in a photorefractive Cu-doped(0.04 wt. %) ${(K_{0.5}Na_{0.5})}_{0.2}{(Sr_{0.61}Ba_{0.39})}_{0.9}Nb_2O_6$ crystal is investigated at 632.8 nm laser wavelength. In addition, the coherent two-wave coupling properties of a photoinduced refractive-index grating in the presence of amplitude modulation on the signal beam or reference beam are also experimentally investigated. Some preliminary exprimental results are presented for use as a dynamic photorefracitive combiners and pulse shaping elements in coherent optical communication systems and in optical signal processing.

  • PDF