• Title/Summary/Keyword: Waveform Parameter Filtering

Search Result 4, Processing Time 0.017 seconds

Real-Time Source Classification with an Waveform Parameter Filtering of Acoustic Emission Signals (음향방출 파형 파라미터 필터링 기법을 이용한 실시간 음원 분류)

  • Cho, Seung-Hyun;Park, Jae-Ha;Ahn, Bong-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.165-173
    • /
    • 2011
  • The acoustic emission(AE) technique is a well established method to carry out structural health monitoring(SHM) of large structures. However, the real-time monitoring of the crack growth in the roller coaster support structures is not easy since the vehicle operation produces very large noise as well as crack growth. In this investigation, we present the waveform parameter filtering method to classify acoustic sources in real-time. This method filtrates only the AE hits by the target acoustic source as passing hits in a specific parameter band. According to various acoustic sources, the waveform parameters were measured and analyzed to verify the present filtering method. Also, the AE system employing the waveform parameter filter was manufactured and applied to the roller coaster support structure in an actual amusement park.

Source parameters for the December 13 1996 ML 4.5 Earthquake in Yeongwol, South Korea (1996년 12월 13일 ML 4.5 영월 지진의 지진원 상수)

  • Choi, Ho-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.23-29
    • /
    • 2009
  • On December 13, 1996, an earthquake with local magnitude (M$_L$) 4.5 occurred in the Yeongwol area of South Korea. The epicenter was 37.2545$^{\circ}$N and 128.7277$^{\circ}$E, which is located inside the Okcheon Fold Belt. The waveform inversion analysis was carried out to estimate source parameters of the event according to the filtering bandwidth of seismic data. Using 0.02$\sim$0.2 Hz filtering bandwidth, focal depth and seismic moment were estimated to be 6 km and 1.3$\times$10$^{16}$ N$\cdot$m, respectively. This seismic moment corresponds to the moment magnitude (M$_W$) 4.7. The focal mechanism by the waveform inversion and P wave first motion polarity analysis is a strike slip faulting including a small thrust component, and the direction of P-axis is ENE-WSW. The moment magnitude estimated by spectral analysis was 4.8, which is similar to that estimated by waveform inversion. Average stress drop was estimated to be 14.3 MPa.

Resonant Filter Characteristics for Electronic Ballast (안정기의 필터 특성에 대한 연구)

  • Han, Soo-Bin;Park, Suck-In;Jeoung, Hak-Guen;Jung, Bong-Man;Song, Eu-Gine;Kim, Gue-Duck
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.222-224
    • /
    • 2006
  • Electronic ballast uses various resonant type filters, which perform many important functions such as filtering the high frequency harmonics, shaping the proper lamp current waveform and regulating the lamp power. In this paper, characteristics of resonant type filters are reviewed and the matching problem between inverter and resonant filter are described. Transfer function which is always necessary for the circuit parameter design is derived in case of LCC filter type as an example.

  • PDF

A Study of Digital EPG Diagnosis Parameter for EPG Standardization (맥진 객관화를 위한 디지탈 맥진기의 진단 파라메터 연구)

  • Lee, J.Y.;Kim, J.H.;Seo, H.W.;Lee, J.W.;Lee, B.C.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3243-3244
    • /
    • 2000
  • From ancient times, the diagnosis method of the oriental medicine has been performed by curing diseases by means of rectifying and adjusting the unbalance in the physiological function of the five viscera and the six bowels of a human body. Diseases have been diagnosed by the condition of blood circulation that cycles a human body through blood vessels by dint of the vitality of the heart. Based on such a systematic pulse diagnosis method, the article presents parameters that will be beneficial to clinical application on the basis of its analysis of the filtering for eliminating noises from pulse signals inputted from sensor group, the digital hardware dealing with signals necessary for recognition algorithm, and the structure of diagnosis algorithm and components of pulse waveform.

  • PDF