• Title/Summary/Keyword: Windage loss

Search Result 20, Processing Time 0.025 seconds

Analysis on the Core Loss and Windage Loss in Permanent Magnet Synchronous Motor for High-Speed Application (고속으로 운전되는 영구자석형 동기전동기의 철손 및 풍손 해석)

  • Jang, Seok-Myeong;Ko, Kyoung-Jin;Cho, Han-Wook
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.10
    • /
    • pp.511-520
    • /
    • 2006
  • Recently, more attention has been paid to the development of high-speed permanent magnet (PM) synchronous motors, since they are conductive to high efficiency, high power density, small size, and low weight. In high-speed PM machines, core loss and windage loss form a larger proportion of the total losses than usual in conventional mid- or low speed machines. This article deals with the analysis on the core loss and windage loss in PM synchronous motor for high-speed application. Using the data information from a manufacturer and non-linear curve fitting, this paper investigates the magnetic behavior and its core losses in the stator core using the electrical steels. And, the windage loss is calculated according to the variation of the rotational speed, motor inner pressure and temperature.

Analysis of Power Loss of an Optical Disc Drive due to the Tilting Motion of a Rotating Disc (ODD 회전 디스크의 틸팅 각운동에 의한 소모전력 해석)

  • Chong, H.Y.;Sung, S.J.;Jang, G.H.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • This paper measured and analyzed the source of total power loss of an ODD of a notebook computer. It shows that the biggest power loss is the windage loss due to the friction between rotating disk and surrounding air. It measured the power loss by the tilting motion of a rotating disc which is originated from the unbalanced mass of the rotating disc or the squareness between case-rotor and shaft. The power loss of rotating disc due to tilting motion was also calculated by using FLUENT, and it was correlated with the measured one. This paper shows that the one of the effective methods to reduce the power loss of an ODD is to reduce the tilting motion of a rotating disc.

A Study on the Flow Friction Loss of a Shrouded Rotating Disk (밀폐된 단일 회전 원판 주위의 유동손실에 관한 연구)

  • 조성욱;임윤철
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.292-297
    • /
    • 2003
  • The fundamental fluid mechanics associated with the rotation of a smooth plane disk enclosed within a cylindrical chamber have been studied experimentally. In order to acquire systematic information pertinent to this problem torque and friction loss data were obtained over a wide range of disk Reynolds numbers for axial clearance-disk radius ratio H/R from 0.025 to 0.2 and radial tip gap-disk radius ratio s/R from 0.021 to 0.105. Loss analysis of hard disk drive (HDD) is presented to describe the contribution of windage loss of a rotating disk. The minimum loss form factor of HDD can be obtained from this analysis at each operation conditions.

Experimental Works and Power Loss Calculations of Surface-Mounted Permanent Magnet Machines

  • Choi, Jang-Young;Ko, Kyoung-Jin;Jang, Seok-Myeong
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.64-70
    • /
    • 2011
  • Surface-mounted permanent magnet (PM) machines were examined experimentally and theoretically, through power loss measurements and calculations. Windage, friction and copper losses were calculated using simple analytical equations and finite element (FE) analyses. Stator core losses were calculated by determining core loss coefficients through curve-fitting and magnetic behavior analysis through non-linear FE calculations. Rotor eddy current losses were calculated using FE analyses that considered the time harmonics of phase current according to load. Core, windage and friction open-circuit losses and copper loss were determined experimentally to test the validity of the analyses.

Performance Prediction on a Partially Admitted Single-Stage Axial-Type Turbine (부분분사에 의하여 작동하는 축류형터빈의 성능예측에 관한 연구)

  • Cho Chong-Hyun;Cho Soo-Yong;Kim Soo-Yong;Choi Sang-Kyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.10-17
    • /
    • 2005
  • A performance prediction model is developed for partially admitted axial-type turbines. Losses generated within the turbine are classified to the windage loss, expansion loss and mixing loss. The developed loss model is compared with an experimental result. The results predicted with the developed model agree well with the experimental results than those predicted with several other models because this model considers three different kinds of losses. Moreover, this model predicts well the performance even the partial admission is changed. So, this model could be applied to predict the performance of partially admitted axial turbine and it has a high accurate performance.

Power and loss characteristics of PMSM/G with double-sided Halbach magnetized rotor (양측식 Halbach 자화 회전자를 갖는 영구자석 동기 전동발전기의 출력 및 손실 특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Choi, Sang-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.723-724
    • /
    • 2008
  • The rotational loss is one of the most important problems for the practical applications of PM synchronous motor/generator. This rotational loss is divided as the mechanical loss by windage and bearing and iron loss by hysteresis loop and eddy current in the part of the magnetic field. So, In this paper, a double-sided PMSM/G without the iron loss is designed by analytical method of the magnetic field and estimation of the back-EMF constant represented as the design parameter. This design model consists of the double-sided PM rotor with Halbach magnetized array and coreless 3-phase winding stator. The results show that the double-sided PMSM/G without iron loss can be applicable to the required system without the rotational loss.

  • PDF

Loss Modeling in order to Predict the Efficiency Performance of Induction Motor Drive System (유도전동기 드라이브 시스템의 효율성능을 예측하기 위한 손실 모델링)

  • 정동화;박기태;이정철
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.56-61
    • /
    • 2000
  • The precise and reliable loss model for induction motor and converter system is very important in order to predict the efficiency performance of variable speed drives. This paper proposes an accurate loss model of induction motor and converter system. The motor losses, such as stator and rotor copper loss, core loss and stray loss, are considered for fundamental and harmonic frequencies. Also considered are the skin effect on rotor resistance, temperature effect on bath stator and rotor resistance, magnetizing inductance saturation, and friction and windage loss. All the above features are incorporated in a synchronous frame dynamic d-q equivalent circuit. The converter system, consisting of a diode rectifier and PWM transistor inverter, is modeled accurately for conduction and switching losses. Validity of the models, in both steady state and transient conditions, is verified by simulations.

  • PDF

Electromagnetic field analysis and performance characteristics of PMSM/G with Halbach magnetized array rotor (Halbach 자화 배열 회전자를 갖는 영구자석 동기 전동발전기의 전자기적 해석 및 성능 특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Ko, Kyoung-Jin;Choi, Sang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.86-88
    • /
    • 2008
  • The rotational loss is one of the most important problems for the practical use of the high power Flywheel Energy Storage System (FESS). This rotational loss is divided as the mechanical loss by windage and bearing and iron loss by hysteresis loop and eddy current in the part of the magnetic field. So, In this paper, a double-sided PMSM/G without the iron loss is designed by analytical method of the magnetic field and estimation of the back-EMF constant represented as the design parameter. This design model consists of the double-sided PM rotor with Halbach magnetized any and coreless 3-phase winding stator. The results show that the double-sided PMSM/G without iron loss can be applicable to the high power FESS.

  • PDF

A study on the flow friction loss of a shrouded rotating disk (밀폐된 단일 회전 원판 주위의 유동손실에 관한 연구)

  • 조성욱;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.159-165
    • /
    • 2001
  • The fundamental fluid mechanics associated with the rotation of a smooth plane disk enclosed within a cylindrical chamber have been studied experimentally. In order to acquire systematic information pertinent to this problem torque and friction loss data were obtained over a wide range of disk Reynolds numbers for axial clearance-disk radius ratio H/R from 0.025 to 0.2 and radial tip gap-disk radius ratio s/R from 0.021 to 0.105. Loss analysis of hard disk drive(HDD) is presented to describe the contribution of windage loss of a rotating disk. The minimum loss from factor of HDD can be obtained from this analysis at each operation conditions.

  • PDF

Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine (부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구)

  • Cho, Chong-Hyun;Cho, Soo-Yong;Choi, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.324-330
    • /
    • 2005
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

  • PDF