• Title/Summary/Keyword: Windows

Search Result 4,085, Processing Time 0.038 seconds

Analysis of Windows Vista Security System for Forensic Examination (포렌식 조사를 위한 윈도우 비스타 보안 체계 분석)

  • Hwang, Seong-Ho;Nam, Hyun-Woo;Park, Neung-Soo;Jo, Su-Hyung;Hong, Do-Won
    • The KIPS Transactions:PartC
    • /
    • v.15C no.3
    • /
    • pp.141-148
    • /
    • 2008
  • Windows Vista published by Microsoft provides more powerful security mechanisms than previous Windows operating systems. In the forensics point of view, new security mechanisms make it more difficult to get data related to the criminals in a storage device. In this paper, we analyze BitLocker introduced as an new security mechanism in Windows Vista. Also, compared to the previous Windows operating systems, the changes and security issues of UAC and EFS in Windows Vista are discussed in the forensics point of view. Futhermore, we discuss other characteristics of Windows Vista useful for forensic examinations.

Design of the Windows CE File System for PDA System (PDA 용 Windows CE 파일 시스템 설계)

  • 김기환;남진우;장승주
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.142-144
    • /
    • 2004
  • 본 논문은 Windows CE의 파일 시스템을 개발하기 위해 필요한 Windows CE .NET 4.0이 제공하는 Platform Builder 통합 개발 환경 툴을 이용하여 파일 시스템 필터를 사용하여 파일시스템을 설계한다. 그리고, Windows CE 에서 사용하는 파일 시스템 필터 encfilt.dll를 이용하여 Windows CE 파일 시스템을 개발할 수 있는 환경을 설정한다.

  • PDF

A Study on the Windows and Doors of Traditional Houses in Jecheon (제천시 전통주거의 창호 특성에 관한 연구)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.94-103
    • /
    • 2013
  • This study investigated the windows and doors of traditional houses in Jecheon, designated as a cultural assets in Chungcheongbuk-do. It aimed to contribute to the study of korean traditional architecture by finding the characteristics of windows and doors, and to the preservation and reuse policy of local cultural assets. This study was conducted using the research methods of the literature and field survey, and it was to analyze and to compare the existing data and a current status. The result are as followings. Firstly, the windows and doors of kitchen in An-chae were generally installed double swinging type with wooden board door(板張門). Secondly, the windows and doors of An-bang were generally installed double swinging type with slender-ribbed windows and doors(細箭窓戶), were mostly installed Merum(遠音). Thirdly, the windows and doors of Daechung(大廳) towards the backyard were generally installed double swinging type with wooden board door, corrugated cardboard door(骨板門) and slender-ribbed windows. Lastly, the windows and doors of Sarang-bang in a house of nobility(班家) was installed triple windows and doors.

A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment (확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

Windows 7 Operating System Event based Visual Incident Analysis System (윈도우즈 7 운영체제 이벤트에 대한 시각적 침해사고 분석 시스템)

  • Lee, Hyung-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.5
    • /
    • pp.223-232
    • /
    • 2012
  • Recently, the leakage of personal information and privacy piracy increase. The victimized case of the malicious object rapidlies increase. Most of users use the windows operating system. Recently, the Windows 7 operating system was announced. Therefore, we need to study for the intrusion response technique at the next generation operate system circumstances. The accident response technique developed till now was mostly implemented around the Windows XP or the Windows Vista. However, a new vulnerability problem will be happen in the breach process of reaction as the Windows 7 operating system is announced. In the windows operating system, the system incident event needs to be efficiently analyzed. For this, the event information generated in a system needs to be visually analyzed around the time information or the security threat weight information. Therefore, in this research, we analyzed visually about the system event information generated in the Windows 7 operating system. And the system analyzing the system incident through the visual event information analysis process was designed and implemented. In case of using the system developed in this study the more efficient accident analysis is expected to be possible.

Novel Push-Front Fibonacci Windows Model for Finding Emerging Patterns with Better Completeness and Accuracy

  • Akhriza, Tubagus Mohammad;Ma, Yinghua;Li, Jianhua
    • ETRI Journal
    • /
    • v.40 no.1
    • /
    • pp.111-121
    • /
    • 2018
  • To find the emerging patterns (EPs) in streaming transaction data, the streaming is first divided into some time windows containing a number of transactions. Itemsets are generated from transactions in each window, and then the emergence of itemsets is evaluated between two windows. In the tilted-time windows model (TTWM), it is assumed that people need support data with finer accuracy from the most recent windows, while accepting coarser accuracy from older windows. Therefore, a limited array's elements are used to maintain all support data in a way that condenses old windows by merging them inside one element. The capacity of elements that accommodates the windows inside is modeled using a particular number sequence. However, in a stream, as new data arrives, the current array updating mechanisms lead to many null elements in the array and cause data incompleteness and inaccuracy problems. Two models derived from TTWM, logarithmic TTWM and Fibonacci windows model, also inherit the same problems. This article proposes a novel push-front Fibonacci windows model as a solution, and experiments are conducted to demonstrate its superiority in finding more EPs compared to other models.

The Impact of Switching Costs on Intention to Stay with MS-Windows (윈도 운영시스템의 지속적 사용의도에 전환비용이 미치는 영향)

  • 현정석
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.1
    • /
    • pp.69-82
    • /
    • 2004
  • The role of switching costs in customer retention has been posited, but has not been subjected to rigorous empirical testing. Therefore, our main focus is on the factors that influence whether consumers will have intention to switch or stay with an incumbent technology (e.g., MS-Windows). Based on consumer survey with MS-Windows users, we find empirical support for the link between the existence of compactible software, consumer's expertise in MS-Windows and intention to stay with MS-Windows. Specifically, switching costs are found to be positively associated with the existence of compatible software. Further, the lack of expertise in MS-Windows on the part of consumers tends to increase the likelihood that they will rely on current MS-Windows, rather than switch to other alternative operating systems.

  • PDF

The Study of Response Model & Mechanism Against Windows Kernel Compromises (Windows 커널 공격기법의 대응 모델 및 메커니즘에 관한 연구)

  • Kim, Jae-Myong;Lee, Dong-Hwi;J. Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.6 no.3
    • /
    • pp.1-12
    • /
    • 2006
  • Malicious codes have been widely documented and detected in information security breach occurrences of Microsoft Windows platform. Legacy information security systems are particularly vulnerable to breaches, due to Window kernel-based malicious codes, that penetrate existing protection and remain undetected. To date there has not been enough quality study into and information sharing about Windows kernel and inner code mechanisms, and this is the core reason for the success of these codes into entering systems and remaining undetected. This paper focus on classification and formalization of type target and mechanism of various Windows kernel-based attacks, and will present suggestions for effective response methodologies in the categories of, "Kernel memory protection", "Process & driver protection" and "File system & registry protection". An effective Windows kernel protection system will be presented through the collection and analysis of Windows kernel and inside mechanisms, and through suggestions for the implementation methodologies of unreleased and new Windows kernel protection skill. Results presented in this paper will explain that the suggested system be highly effective and has more accurate for intrusion detection ratios, then the current legacy security systems (i.e., virus vaccines and Windows IPS, etc) intrusion detection ratios. So, It is expected that the suggested system provides a good solution to prevent IT infrastructure from complicated and intelligent Windows kernel attacks.

  • PDF

Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio (창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jeong, Hak-Geun;Kim, Jong-Hun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

Experimental study on reduction in rain water penetration through industrial windows used for natural ventilation (자연환기용 공장창호의 빗물유입 저감대책에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae-Hyeung;Ha, Hyun-Chul;Xu, Rong Bin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.175-183
    • /
    • 2010
  • Windows are widely used for natural ventilation of the various buildings. Especially high level windows as a part of industrial ventilation systems, play a crucial role in natural ventilation. Compared to mechanical ventilation system, natural ventilation has the advantage of lower installation and operating costs. In general, high level windows for industrial buildings have three types; louver type, 45$^{\circ}$ open type and 90$^{\circ}$ open type. Based on previous studies, it was found that the louver type and 45$^{\circ}$ open type are very effective in reducing rainwater penetration, but they did not have enough ventilation efficiencies. Preliminary tests were performed with the various types of windows. It was found that a 90$^{\circ}$ open double layer type window was the best among those which tested in our preliminary tests. Simulated rain was used to estimate the amount of rain penetrated through windows and to observe the paths of rain penetration. Various 90$^{\circ}$ open windows were tested to find the windows with minimum rain penetration and maximum ventilation efficiency.