• Title/Summary/Keyword: Wire Height

Search Result 142, Processing Time 0.036 seconds

The Low Height Looping Technology for Multi-chip Package in Wire Bonder (와이어 본더에서의 초저 루프 기술)

  • Kwak, Byung-Kil;Park, Young-Min;Kook, Sung-June
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.17-22
    • /
    • 2007
  • Recent new packages such as MCP(Multi-Chip Package), QDP(Quadratic Die Package) and DDP(Dual Die Package) have stack type configuration. This kind of multi-layer package is thicker than single layer package. So there is need for the low height looping technology in wirebonder to make these packages thinner. There is stiff zone above ball in wirebonder wire which is called HAZ(Heat Affect Zone). When making low height loop (below $80\;{\mu}m$) with traditional forward loop, stiff wire in HAZ(Heat Affected Zone) above ball is bended and weakened. So the traditional forward looping method cannot be applied to low height loop. SSB(stand-off stitch) wire bonding method was applied to many packages which require very low loops. The drawback of SSB method is making frequent errors at making ball, neck damage above ball on lead and the weakness of ball bonding on lead. The alternative looping method is BNL(ball neckless) looping technology which is already applied to some package(DDP, QDP). The advantage of this method is faster in bonding process and making little errors in wire bonding compared with SSB method. This paper presents the result of BNL looping technology applied in assembly house and several issues related to low loop height consistence and BNL zone weakness.

  • PDF

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Shape Optimization of the Cross Section for a Non-circular Spring Wire of Valve Springs for an Automotive Engine (자동차 엔진 밸브 스프링에 사용되는 비원형 스프링 선의 단면 형상 최적화)

  • Kim, Do-Joong;Kim, Young-Kyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2011
  • Valve springs with non-circular cross-section are widely used in automotive engines. Because of the reduced height, the oval cross-section provides some merits in its install height and stress distribution. This paper introduces a new method to generate optimal shape of the non-circular cross-section. For given width and height, arbitrary shape of the cross-section are described using the Hermite spline curves. Cross-section area and maximum stress level are chosen as performance indices, and nonlinear optimization problems are formulated with inequality constraints. Compared to a production spring wire, cross-section area can be reduced about 2.4 [%] without increasing maximum stress level. In addition, the other approach gives an optimum cross-section which reduces maximum stress level of 2.0 [%] without increasing cross-section area.

Strengthening of axially loaded concrete columns using stainless steel wire mesh (SSWM)-numerical investigations

  • Kumar, Varinder;Patel, P.V.
    • Structural Engineering and Mechanics
    • /
    • v.60 no.6
    • /
    • pp.979-999
    • /
    • 2016
  • Stainless steel wire mesh (SSWM) is an alternative material for strengthening of structural elements similar to fiber reinforced polymer (FRP). Finite element (FE) method based Numerical investigation for evaluation of axial strength of SSWM strengthened plain cement concrete (PCC) and reinforced cement concrete (RCC) columns is presented in this paper. PCC columns of 200 mm diameter with height 400 mm, 800 mm and 1200 mm and RCC columns of diameter 200 mm with height of 1200 mm with different number of SSWM wraps are considered for study. The effect of concrete grade, height of column and number of wraps on axial strength is studied using finite element based software ABAQUS. The results of numerical simulation are compared with experimental study and design guidelines specified by ACI 440.2R-08 and CNR-DT 200/2004. As per numerical analysis, an increase in axial capacity of 15.69% to 153.95% and 52.39% to 109.06% is observed for PCC and RCC columns respectively with different number of SSWM wraps.

Implementation of Optical-based Measuring Instrument for Contact Wire Geometry in Electric Railway (전기철도의 전차선로 형상검측을 위한 광학기반 검측 장치 구현)

  • Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Lee, Ki-Won;Kim, Hyung-Chul;Kwon, Sam-Young;Park, Hyun-June;Kim, Won-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.868-871
    • /
    • 2008
  • We propose an optical-based measuring instrument of catenary system in electric railway. This system was made to utilize line scan camera as inspecting system to measure the stagger and height of overhead contact wire in railway and composed with optical type source and FPGA-based image acquisition system with PCI slot. Vision acquisition software has been used for the application to programming interface for image acquisition, display, and storage with a frequency of sampling. To check the validity of our approach for the intended application, we monitored height and stagger in the overhead wire of a high-speed catenary system in Korea. The proposed optical-based measuring instrument to measure the contact wire geometry such as the hight and stagger shows promising on-field applications for online condition motoring. We expect that a new generation of real-time instruments with demanding various conditions motoring requirement in railway can be easily integrated into optical-based measuring instrument system.

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

Study of Failure Examples of Automotive Electronic Control Suspension System Including Cases with Wiring Disconnection and Air Leakage (배선 단선과 에어 누설에 관련된 자동차 ECS 시스템의 고장사례 고찰)

  • Lee, Il Kwon;Park, Jong Geon;Shin, Myung Shin;Jang, Joo Sup
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.180-185
    • /
    • 2013
  • The purpose of this study was to analyze the tribological characteristics of the Electronic control suspension System in a car. In the first example, the cilp used to attach the front electronic control suspension(ECS) system's control actuator was fastened very tightly. Thus, the wire was cut because of continual rotation of the shock-up shover piston rod used to adjust the height of the car. This verified the disconnection phenomenon where wire damaged makes it impossible for the ECS system to send signal to the actuator. The second example, involved a minute hole that allowed gas to leak from the ECS system. As a result, the height of the car verified the down phenomenon. In the third example, the resistance of a wire measured at $0.21{\Omega}$, when the G sensor was disconnected from the system. This verified the system shutdown and lighting of the ECS warning lamp because of body interference caused by a slight pressure on the battery cover. Therefore, quality control is always necessary to ensure safety and durability of a car.

Experimental Study on The Propagation Characteristics of Lightning Surge According to Variation of Wire Length (배선 길이 변화에 따른 뇌서지 전파 특성에 대한 실험 연구)

  • Seo Ho-Joon;Rhie Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.12
    • /
    • pp.616-619
    • /
    • 2004
  • Electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. To achieve effective method of surge protection, there are needs for correlation between lightning surge and indoor wire length or installation height of indoor wire. The aim of this present work is to investigate the propagation characteristics of lightning surge according to variation of wire length. As a consequence, the maximum voltage at the end of the open wire in proportion to length of indoor wire. Therefore this result may be raw data for establishment of surge protection system.

The Analysis of Pattern Components of Brassiere and Study on Its Making (브래지어의 패턴 구성요소 분석 및 제작법 연구)

  • Lee, So-Young
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.15 no.2
    • /
    • pp.15-26
    • /
    • 2013
  • The purpose of this study is to offer basic data for designing and making of brassiere with the consideration of the physiological nature of man. Each of 3/4-cup wired upward-support-type Mold Bra of 75 size with basic pad made at three representative domestic companies (A, B and C Company) was selected for analysis of pattern and components. The following is the result of this study. 1. That Company A's bra had the highest cup, relatively narrow width, the widest front-center and the highest front center at front pad. That of Company B had relatively short wing over the base and much difference at the height of cup depending on the presence of wire. That of Company C had low and wide cup, the widest bust span and the front center width, the front center height of front pad, the base length of front pad and the length of wings were observed to be of the figures between those of Company A and B. 2. The Bra of Company A had the biggest front center angle of $6^{\circ}$, while that of Company C had the biggest wing angle of $18^{\circ}$. The Bra of Company B showed the biggest difference of patterns depending on the presence of wire. Those of Company A and C showed very similar shape when wire was inserted. 3. The order of making brassiere is following: making of exterior mold cup${\rightarrow}$ sewing exterior cup and circumference of mold${\rightarrow}$ sewing base and wings${\rightarrow}$ sewing binding tape to base${\rightarrow}$ sewing cup and main pad${\rightarrow}$ sewing binding tape to upper sides and upper part of wings${\rightarrow}$ sewing wire-tape to interior base of cup${\rightarrow}$ inserting of wire inside wire-tape${\rightarrow}$ sewing hook & eye on the back of wings${\rightarrow}$ sewing shoulder string.

  • PDF

Effects of Design Variables on Compression Rate of Wire in Connector Crimping Process of Wire Harness Using FEM (와이어 하네스의 압착공정에서 설계변수가 압축률에 미치는 영향 연구)

  • Gu, S.M.;Choi, H.S.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.5
    • /
    • pp.305-310
    • /
    • 2010
  • Recently industry of motor vehicle is making a gradual progress of automotive electric components. According to this step, wire harness equipped at motor vehicle is also increased. The most important component at the wire harness is electric connector. At the manufacturing process of electric connector, exactly at the crimping process, design variables, such as clamping-height, clamping-width and clamping die shape are critical parameters to assure satisfactory harness shape in clamping process of electric connector. In this study we have performed FEM simulation for clamping process and clarified the effect of design variables on compression rate of wire.