• Title/Summary/Keyword: Wooden Cultural Properties Building

Search Result 23, Processing Time 0.029 seconds

A Study about Research on the Actual Condition for Fire Counterplan of Main Temple Wooden Cultural Properties (중요사찰목조문화재의 소방대책을 고려한 실태조사에 관한 연구)

  • Back, Min-Ho;Shin, Ho-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.121-130
    • /
    • 2009
  • This study is researched about the field trip of temples and the data for fire extinguishment manual of fire stations: it is done from June 2008 to December 2008 the 80 main temple wooden cultural properties among the 124 main wooden cultural properties appointed by the Cultural Heritage Administration. Cultural properties appointment classification, location classification, temple area, building area in a temple, building area of appointment cultural properties, a fire engine drive direction for fire suppression in a fire, distance from a fire station, and present condition of a fire administrator are researched. The cultural properties possess characteristic is in 2 cases: the whole things in a temple are appointed as cultural properties and only the wooden building is. The cultural properties are classified: the transport is possible or not. The special quality of cultural properties are classified for early correspondence and cultural properties transport in a fire and the basic data are arranged for damage limitation.

Pest control managements for preservation of wooden cultural properties (목조문화재의 원형보존을 위한 충해 방제방안)

  • Lee, Kyu-Sik;Jeong, So-Young;Chung, Yong-Jae
    • 보존과학연구
    • /
    • s.21
    • /
    • pp.5-55
    • /
    • 2000
  • The cultural properties are damaged by various causes according to the characteristics of material, the condition of preservation, and the period of time. Especially, biodeterioration makes lots of damages in organic properties than inorganic ones. The damages of wooden cultural properties by insects usually are caused by the three orders; Isoptera, Coleoptera, and Hymenoptera. As the result of investigation on the state of 141 buildings of wooden cultural properties in 1999, some of them were damaged by many kinds off actors; wasp, powder post beetle, cigarette beetle, termite, decay, and physical cracking. And it was found that the patterns of damages were related to species-specific habits of insects. There are several methods of pest control for the prevention of wooden cultural properties from damages caused by insects. Those are as follows; physical control, chemical control, biological control, and integrated pest management. When insects and fungi were detected at the wooden buildings, the fumigation is best treatment to stop biodeterioration. And then, wood materials also need to be treated with insecticidal and antiseptic chemicals to avoid a reinfestation, because the fumigant is volatile. The six commercial chemicals which are applied to the insecticidal and antiseptic treatment of wooden cultural properties were purchased to test their abilities. According to the comparative results of efficacy of them in laboratory, chemical D showed excellent efficacy in all items, including antiseptic and termiticidal items. The goal of these pest controls is to protect wooden buildings from insects and microorganisms. The most effective method used currently is chemical control(fumigation, insecticidal and anticeptic chemical treatment), but it has to be treated periodically to control pest effectively. Recently environmentally-friendly control methods such as bait system or biological treatments are replacing traditional barrier treatments using large amounts of chemicals. Especially, termite is a social insect which makes a colony. Although a building with fumigation treatment is safe for a while, once attacked building has a risk of damage by reinfestation of termite. Therefore, to control termites from damaged building, the entire colony including reproductives(queen and king) and larvae around buildings must beeliminated. Bait system can be used as a preventive measure in early detection of them through termites colony monitoring and baiting. It would be the most effective for termite control if bait system would be used together with the chemical controls.

  • PDF

The Study for Fire Prevention of Main Wooden Cultural Properties of Korea (국가지정 목조문화재의 소방대책에 관한 실태조사)

  • Back, Min-Ho;Lee, Ji-Hyang
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is searched in the on actual condition and analysis about the fire fighting measure of 123 main wooden cultural properties designated by the Cultural Heritage Administration. First, the management of wooden cultural properties and the present condition of fire occurrence are arranged. Second, The field research and the information research of related government agencies are done from August. 2008 to October. 2008 about 123 main wooden cultural properties: Cultural properties designation classification, location classification, building area, number of possession cultural properties, present condition of fire fighting, a fire engine drive direction for fire suppression, number of self-defense fire brigade, fire administrator nomination, and the distance and time from a fire station are arranged in this study. Third, the inside and outside present conditions are classified and analyzed by average index for the fire occurrence risk of 123 main wooden cultural properties. And the basic data is arranged for the fire fighting measure of main wooden cultural properties.

Termite monitoring and control managements for wooden building (목조건조물의 흰개미 모니터링 및 방제방법)

  • Lee, Kyu-Shik;Jeong, So-Young;Chung, Yong-Jae
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.41-52
    • /
    • 2001
  • The wooden building is mainly damaged by the termite which have an effect of the structure by making emptied inner part of wood. One class, Japanese termite, inhabits throughout Korea and is often detected. So the deterioration by termite attacking the wooden building needs to be controlled. Termites are over 2,800 species in the world, usually they inhabit in the tropical or subtropical region and don’t over winter in dormant condition. So their activity and distribution are chiefly restricted by temperature and humidity. The termite inhabiting in Korea is Reticulitermes speratus kyushuensis Morimoto, which known to have an optimal temperature range at $12~30^{\circ}C$ and minimum temperature at $6^{\circ}C$ for activation. These temperatures correspond to the mean temperature($5.6^{\circ}C$~$25.8^{\circ}C$) from March to November and the activity time of termitein Seoul. In addition, as a result of environmental pollution by industrial development, the climate of Korea is getting warm. The increase of mean temperature in Korea has been $1.1^{\circ}C$ for the past seventy five years, so it is expected that the damage of wooden building by termite will increase gradually. Therefore, in order to protect wooden building from damages by termite, it needs not only development of new pest control methods, but also studies on the control of environmental factors having an effect on the activity and growth of termite. For the conservation of the large cultural properties such as the wooden building in the open air, it would be effective to use the methods of fumigation, insecticidal and antiseptic chemical treatment of wood materials, soil termiticideinjection treatment, and termite colony elimination system.

  • PDF

Study on the Adaption Technique for Detection of Termites using Microwave (극초단파(Microwave)를 이용한 흰개미 탐지기술 적용연구)

  • Kim, Dae-Woon;Jeong, Seon-Hye;Lee, Sang-Hwan;Chung, Yong-Jae
    • Journal of Conservation Science
    • /
    • v.26 no.1
    • /
    • pp.77-83
    • /
    • 2010
  • The damage from the underground termite cannot be discovered with peculiar appearance of building but hollow phenomenon will occur. But there is no case in Korea as a non-destructive measurement of termite activation. Therefore, this research constructs non-destructive diagnostic techniques for wooden cultural properties using microwave detector (Termatrac, Australia). Result of maximun distance were measured 16cm (Pine tree, sensitivity 5, 6), 17cm (Zelkova and Douglas fir, sensitivity 5, 6). These results are expected that can be applied in the field. Result of field test using microwave detector, 33.8% of the wooden cultural properties were damaged by termites, and until now 7.8% (18 buildings) are being damaged in nationwide (total 231 buildings). Based on the above results, microwave detector will be able to be utilized effectively for detecting termite, preventing intrusion in wooden structure, and making full use of monitoring system periodically. In addition, it could be of great worth in preventing insect and microorganism in wooden structure.

The Expressional Principles of Wooden Brackets in Jusimpo Style - Focusing on Temple building - (주심포식 공포의 표현원리 - 사찰건축과 그 지붕형태를 중심으로 -)

  • Choi, Go-Eun
    • Journal of architectural history
    • /
    • v.14 no.3 s.43
    • /
    • pp.103-118
    • /
    • 2005
  • This study is about the meaning of wooden brackets that are distinctive elements of wooden architecture in Korea, Japan, and China. Existing studies about wooden brackets have been limited to the boundary of formalism, so the object of this study is to make a breakthrough in the field of those studies. The Wooden brackets in this study are considered to be decorative elements, and the principles of their design are examined. The specific subject of the study is wooden architecture with Jusimpo-styled brackets that have brackets only on pillars. The definition of Jusimpo is reexamined first, and ChulMok-Ikkong which has not been regarded as a Jusimpo-styled wooden bracket is interpreted as Jusimpo-styled one in this study. Categorized into three types, Jusimpo is examined how it is expressed according to the type of the roof in a building. In view of the results, the wooden bracket system is an effective technique to express the formality, and two designing principles can be seen in Jusimpo; one that wooden brackets observed externally are standardized and regarded as the same ones, and the other that the style of wooden brackets used in the most formal building is Yi-ChulMok. These designing principles mean that the carpenter who was in charge of building the architecture had certain principles when expressing wooden brackets as well as the roofs according to the class of the architecture. In addition, although the styles of wooden brackets that were used in the most formal architecture during the Chosun period were mostly Dapo, Jusimpo in the form of Yi-ChulMok was also adopted in some temples depending on their scale, and that means Jusimpo-styled wooden brackets were never considered to be inferior to Dapo-styled ones. And this point leaves the argument that the reexamination of Jusimpo-styled wooden brackets which have been regarded as the style used in the attached building or small structures since the Choun dynasty should be conducted.

  • PDF

Monitoring of Termite in Haeinsa Temple and Control method (해인사의 흰개미 모니터링 및 방제 방안)

  • Jeong, So-Young;Lee, Kyu-Shik;Chung, Yong-Jae
    • 보존과학연구
    • /
    • s.23
    • /
    • pp.77-93
    • /
    • 2002
  • There are several methods of pest control for the prevention of wooden cultural properties from damages caused by insects, especially termites. Those are as follows; physical control, chemical control, biological control, and integrated pest management. In Korea, we primarily use mvestigation of monitoring, fumigation, treatment of insecticidal and antiseptic chemicals, soil termiticide treatment, and termite colony elimination system. As damages by termites were detected at Eunghyanggak and Saundang of Haeinsa temple in June, 1998, we carried out monitoring with wooden device, in order to investigate damages of wooden building by termite and paths of termite invasion. According to the result of investigation of monitoring from1999 to 2002, we found that termites were inhabiting continually at forests around Haeinsa and that wooden buildings such as Saundang, Cheonghwadang were damaged by termites. So we thought that control methods such as soil termiticide treatment and termite colony elimination system would be effective. Especially, to investigate efficacy of termite colony elimination system, we carried out efficacy test of termite colony elimination system in Jongmyo during 17 months(2000.7.~2001.11.). The result of efficacy test showed that termite colony elimination system eliminated termite colonies gradually(over 12 months from installation of colony elimination system to elimination of termite colony).

  • PDF

Deterioration and Preservation Technique of Wooden Cultural Properties (Part 2) -Biodeterioration of Square Post to Support Wooden Printing Blocks Shelves, Janggeongpanjeon- (목조문화재 열화 및 보존기술에 관한 연구(제2보) -장경각 구조부재중 실내 판가 기둥의 생물적 열화 특성-)

  • Kim, Yeong-Suk;Han, Sang-Mi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.64-72
    • /
    • 2007
  • The biodeterioration behaviors of square post to support the wooden printing blocks Shelves in the Janggeongpanjeon were investigated according to the positions and parts of square post, and environmental conditions. It was found that a high differences of deterioration in the progressing levels of wood decay, according to the positions and parts of square post, and environmental conditions. The decay levels were very high and still progressing in the contacted areas with stone foundation which are about up to 50 cm above it. In the decay type, white rot fungi was mainly affected in the inside of building which mainly made of softwood. The decay in the square posts to support the wooden printing block shelves inside of building was worse in the rear side, compared to front side. The insects was not found in most of square posts excluding the post which was neighboring at the infected round column by insect.

Biological Damage and Risk Assessment of The Wood Cultural Properties in Fire Prevention Area (화재방제구역에 따른 목조문화재 생물손상 및 생물위험도 평가)

  • Kim, Dae Woon;Chung, Yong Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.104-111
    • /
    • 2015
  • The three-year inspection of 20 tree stumps in the fire prevention area around the wooden building confirmed that termite colonies had been rapidly spread. In particular, four buildings among thirty one wooden buildings of Songgwang-sa temple were infected by the termite, indicating that the habitate of termite has been spread across the fire prevention area over the temple area. However, a non-destructive microwave diagnosis showed that internal damages have been progressed until now, suggesting a high risk to the building. These results suggest that the fire prevention area should be properly maintained to have harmful element controlled. Therefore, effective methods are required to eliminate tree stumps or wood materials used to establish fire prevention area near wooden buildings.

A Study on the Characteristic Micro-Climate of Myeong-Kwan Kim House and the Moisture Content Behavior of Outside Exposed Columns (김명관고택의 미기후 특성과 외진노출기둥의 함수율 양상에 관한 연구)

  • Park, Yong-Shin;Kim, Yun-Sang
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.3
    • /
    • pp.33-40
    • /
    • 2020
  • Wood is one of the main materials of wooden building. Hanok also uses wood as its main component. Recently, Hanok continues to be built. Wood is affected by the climatic environment. The growth of decay bacteria is activated at more than 80% relative humidity. The microclimate environment and moisture content were measured for architectural cultural properties that have been maintained for a long time as a wooden building. The method analyzed the measured data by distinguishing between cloudy and sunny days. In the case of the old house, Anchae moisture content was higher than that of Sarangchae. This seems to be due to the narrow front yard or the planting of trees. The microclimate environment inside the house began to decrease in humidity from 8 am. According to the survey data, the relative humidity was less than 80% from 9 am when there was wind around 4-6 am. It appeared an hour earlier than in the absence of wind. As a result, the time interval for dehumidifying of wood was widened. Therefore, the wooden building is open to the front so there is airflow under the eaves during the daytime and wind in the morning appear to be alternatives in order to lower the moisture content.