• Title/Summary/Keyword: Z-Source

Search Result 485, Processing Time 0.033 seconds

PWM Control of Reduced Switch Z-Source Inverter (스위치 저감형 Z-Source Inverter PWM 제어)

  • Kim, Seong-Hwan;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.53-57
    • /
    • 2019
  • In this paper, we propose a new Z-source inverter structure to reduce switching elements and PWM pulse control method. Z-network is connected between the inverter backplane and ground, rather than between the DC voltage and the inverter in an improved Z-source inverter. And the improved Z-source inverter has the advantages of limiting the capacitor inrush current and reducing the capacitor voltage stress. We have proposed a topology of a new type of switch-reduced improved Z-source inverter that reduces the number of switches from six to four in an improved Z-source inverter and developed a PWM control method suitable for the proposed topology. The characteristics and the performance of the proposed method were verified by using PSIM simulation.

Output Voltage Control of Z-Source Inverter by the Detection of the Input DC Voltage and Z-Network Capacitor Voltage (입력 직류 전압과 Z-네트워크 커패시터 전압 검출에 의한 Z-소스 인버터의 출력 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposes the algorithm for the output AC voltage control of Z-source inverter by the detection of the input DC voltage and Z-network capacitor voltage. The actual modulation index of the proposed method is detected by the capacitor voltage in Z-network and input DC voltage of three-phase Z-source inverter. Control modulation index for the output voltage control is calculated by the detected actual modulation index and reference modulation index. And, calculated control modulation index is applied to the modified space vector modulation (SVM) for control the output voltage of Z-source inverter. To verify the validity of the proposed method, PSIM simulation was achieved and a DSP controlled 1[kW] three-phase Z-source inverter was producted. The simulation and experiment were performed under the condition that the load was changed in case of the constant input DC voltage and the input DC voltage was changed in case of the load was constant. As a result, we could know that the output phase voltage of Z-source inverter followed to the reference voltage 70[VRMS] despite the load or the input DC voltage were suddenly changed.

Switched Inductor Z-Source AC-DC Converter

  • Sedaghati, Farzad;Hosseini, Seyed Hossein;Sarhangzadeh, Mitra
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.67-76
    • /
    • 2012
  • Due to the increasing amount of applications of power electronic ac-dc converters, it is necessary to design a single-stage converter that can reliably perform both buck and boost operations. Traditionally, this can be achieved by double-stage conversion (ac/dc-dc/dc) which ultimately leads to less efficiency and a more complex control system. This paper discusses two types of modern ac-dc converters. First, the novel impedance-source ac-dc converter, abbreviated as custom Z-source rectifier, is analyzed; and then, switched inductor (SL) Z-source ac-dc converter is proposed. This paper describes the Z-source rectifiers' operating principles, the concepts behind them, and their superiorities. Analysis and simulation results show that the proposed custom Z-source rectifier can step up and step down voltage; and the main advantage of the SL Z-source ac-dc converter is its high step-up capability. Low ripple of the output dc voltage is the other advantage of the proposed converters. Finally, the SL Z-source ac-dc converter is compared with the custom Z-source ac-dc converter.

Three-Phase Z-Source Hybrid Active Power Filter System (3상 Z-소스 하이브리드 능동전력필터 시스템)

  • Lim, Young-Cheol;Kim, Jae-Hyun;Jung, Young-Gook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.75-85
    • /
    • 2010
  • In this paper, a Z-source hybrid active power filter is proposed to compensate the harmonics and reactive power in power distribution system. The proposed system is composed of a 7th harmonics-tuned passive filter and an active power filter with a Z-source inverter topology, while voltage source PWM inverter or current source PWM inverter are applied as the power converter topology of conventional active power filters. The Z-source impedance network along with shoot through capability would ensure a constant DC voltage across the DC link. A polymer electrolyte membrane fuel cell is employed as an compensation DC energy source of the proposed system and its equivalent R-L-C circuit is modeled for simulation. As the compensation and control algorithm of the proposed system, the current synchronous detection algorithm is applied. The simulation analysis by PSIM is performed under the three-phase 220V/60Hz voltage source and 25A nonlinear diode loads. The effectiveness of the proposed the system is verified in the steady and transient states.

Characteristics of the Stress Reduction and Output Voltage of ST(Switched Trans) Quasi Z-Source Inverter (ST Quasi Z-소스 인버터의 스트레스 저감과 출력전압 특성)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This paper proposes a ST(Switched Trans) quasi Z-source inverter using a Switched Trans Cell combing the characteristics of a Switched Inductor Cell and Trans. A DC link inductor of the conventional quasi Z-source inverter is alternated with Switched Trans Cell of the proposed ST quasi Z-source inverter. Trans Cell of the proposed method consists of one Trans and two diodes, and the proposed method has higher and more various boost function than the conventional quasi Z-source inverter by simply changing the turns ratio of primary and secondary of the Trans. The validity of the proposed ST Z-source inverter was confirmed by PSIM simulation and a DSP based experiment under the input voltage 48V and output phase voltage 30V. As a result, when compared with the traditional quasi Z-source inverter, the proposed method has the advantage of the low voltage stress under the same output voltage condition of the voltage.

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.

Voltage THD Mitigation of Power Distribution System using Z-Source Active Power Filter with a Fuel Cells Source (연료전지 전원을 갖는 Z-소스 능동전력필터에 의한 장거리 배전선로의 전압 THD 저감)

  • Jung, Young-Gook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2161-2166
    • /
    • 2008
  • This paper deals with a Z-source active power filter(Z-AFU) for mitigation voltage THD(total harmonic distortion) due to voltage harmonic propagation(amplification) in 6.6kv power distribution system. Bus voltage harmonic signal is detected by 60Hz butterworth BPF(band pass filter). As an ESS(energy storage system) of the proposed system, PEM fuel cells(Ballard NEXA, 1.2kw) is employed. Test results based on PSIM(power electronics simulation tool) validate the proposed approach.

Single-phase Trans-Z-Source AC-AC Converter (단상 트랜스-Z-소스 AC-AC 컨버터)

  • Shin, Hyunhak;Chae, Junyoung;Joung, Minjae
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.407-408
    • /
    • 2015
  • The existing (q)Z-source PWM AC-AC converters have limited voltage gain because of the equivalent series resistance in the Z-source inductor. In order to obtain higher voltage gain than (q)Z-source AC-AC converters, a coupled inductor (or transformer) based Z-source AC-AC converter is proposed in this paper. By increasing turns ratio of the coupled inductor more than 1, the proposed converter can obtain higher output voltage than (q)Z-source converters with the same duty ratio. A 120 W prototype AC-AC converter is built and tested to verify performances of the proposed converter.

  • PDF

Comparison of the Voltage Stress and Voltage Gain of the Switched Trans Z-source Inverters (스위치드 변압기 Z-소스 인버터의 전압 스트레스와 전압이득 비교)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.376-377
    • /
    • 2013
  • 본 연구에서는 양방향 인덕터 대신 단방향 변압기 셀을 이용한 Switched Trans Z-source inverter, Switched Trans Quasi Z-source inverter, Switched Trans-inductor Quasi Z-source inverter의 전압 이득 및 스트레스를 비교하였다.

  • PDF

Quasi Z-Source Inverter with Switched Trans Inductor (Switched Trans Inductor를 갖는 Quasi Z-소스 인버터)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.374-375
    • /
    • 2013
  • 본 연구에서는 종전의 Quasi Z-source inverter의 장점을 그대로 가지고 있으면서 동일한 동작 조건에서 낮은 스트레스를 보이는 Switched Trans-inductor Z-source inverter를 제안하였다. 제안된 방식은 동일한 조건에서 낮은 전압 스트레스와 전류 스트레스를 가지고 동작 가능하였으며, 따라서 낮은 용량의 수동소자와 능동소자로도 Z-source inverter 구현이 가능하였다.

  • PDF