• 제목/요약/키워드: Zirconium dioxide

검색결과 29건 처리시간 0.029초

Color variation induced by abutments in the superior anterior maxilla: an in vitro study in the pig gingiva

  • Atash, Ramin;Boularbah, Mohamed-Reda;Sibel, Cetik
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.423-432
    • /
    • 2016
  • PURPOSE. The aim of this work is to evaluate different types of materials used for making implant abutments, by means of an in vitro study and a review of the literature, in order to identify the indications for a better choice of an implant-supported restoration in the anterior section. MATERIALS AND METHODS. 5 implant abutments were tested in a random order in the superior anterior maxilla of pig gingiva (n = 8): titanium dioxide (Nobel Biocare); zirconium dioxide, Standard BO shade (Nobel Biocare, Kloten, Switzerland); zirconium dioxide, Light BI shade (Nobel Biocare); zirconium dioxide, Intense A 3.5 shade (Nobel Biocare); and aluminium oxide. Each abutment was tested for 2 mm and 3 mm thickness. To determine color variation, VITA Easyshade Advance spectrophotometer (Vita Zahnfabrik, Bad Sackingen, Germany) was used. RESULTS. Results showed that the color variation induced by the abutment would be affected by the abutment material and gingival thickness, when the gingival thickness is 2 mm. All materials except zirconium dioxide (Standard shade) caused a visible change of color. Then, as the thickness of the gingiva increased to 3 mm, the color variation was attenuated in a significant manner and became invisible for all types of abutments, except those made of aluminium oxide. CONCLUSION. Zirconium dioxide is the material causing the lowest color variation at 2 mm and at 3 mm, whereas aluminium oxide causes the highest color variation no matter the thickness.

Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas

  • Yus, Estefania Aranda;Cantarell, Josep Maria Anglada;Alonso, Antonio Minarro
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.236-244
    • /
    • 2018
  • PURPOSE. To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. MATERIALS AND METHODS. From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal, Vestibular and Palatal), and the marginal fit was evaluated with SEM (${\times}600$). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. RESULTS. Mean marginal discrepancy was $22.42{\pm}35.65{\mu}m$ in the silicone group and $8.94{\pm}14.69{\mu}m$ in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant (P=.02). CONCLUSION. The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.

Improving the Neutronic Characteristics of a Boiling Water Reactor by Using Uranium Zirconium Hydride Fuel Instead of Uranium Dioxide Fuel

  • Galahom, Ahmed Abdelghafar
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.751-757
    • /
    • 2016
  • The present work discusses two different models of boiling water reactor (BWR) bundle to compare the neutronic characteristics of uranium dioxide ($UO_2$) and uranium zirconium hydride ($UZrH_{1.6}$) fuel. Each bundle consists of four assemblies. The BWR assembly fueled with $UO_2$ contains $8{\times}8$ fuel rods while that fueled with $UZrH_{1.6}$ contains $9{\times}9$ fuel rods. The Monte Carlo N-Particle Transport code, based on the Mont Carlo method, is used to design three dimensional models for BWR fuel bundles at typical operating temperatures and pressure conditions. These models are used to determine the multiplication factor, pin-by-pin power distribution, axial power distribution, thermal neutron flux distribution, and axial thermal neutron flux. The moderator and coolant (water) are permitted to boil within the BWR core forming steam bubbles, so it is important to calculate the reactivity effect of voiding at different values. It is found that the hydride fuel bundle design can be simplified by eliminating water rods and replacing the control blade with control rods. $UZrH_{1.6}$ fuel improves the performance of the BWR in different ways such as increasing the energy extracted per fuel assembly, reducing the uranium ore, and reducing the plutonium accumulated in the BWR through burnup.

Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis

  • Chagas, Mariana Murai;Kobayashi-Velasco, Solange;Gimenez, Thais;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.363-372
    • /
    • 2021
  • Purpose: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. Materials and Methods: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. Results: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects(0.73) and fenestration defects(0.87) showed a statistically significant difference. Conclusion: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.

액상계면반응에 의한 실라카 중공 다공성 미소구의 제조 및 표면개질에 의한 특성

  • 정원범;고종성
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • 제13권1호
    • /
    • pp.15-28
    • /
    • 1987
  • Silica spheres were prepared by interfacial reaction method. Factors in-fluencing to the mean particle size and specific surface area of silica spheres were investigated. The experiment about the surface modification of silica spheres was carried out. It was observed that silica spheres have characteristics of the spherical shape with the vacancy in the inner side, high surface area, and reaction tendency by many silanol group. The mean particle size of silica spheres is dependent on the surfactant concentration and W/O ratio. The specific surface area is influenced by SiO2/Na2O mole ratio in sodium silicate. Silica spheres coated with titanium dioxide or zirconium dioxide improve the UV protection effect. Titanate and silane coupling agent make chemical bond with silica surface and improve the organophile and the dispersibility of silica spheres.

  • PDF

Electrostatic Interaction between Mercaptoundecanoic-acid Layers on Gold and ZrO2 Surfaces (금 표면 위의 메르캡토언데카노익산층 표면과 이산화지르코늄 표면 사이의 정전기적 상호작용)

  • Park, Jin-Won
    • Applied Chemistry for Engineering
    • /
    • 제25권6호
    • /
    • pp.607-612
    • /
    • 2014
  • The physical properties of mercaptoundecanoic-acid layer formed on gold surfaces, which may affect the distribution of either gold particles adsorbed to the zirconium dioxide surface or vice versa, were investigated. To conduct this investigation, the surface forces were measured between the surfaces with respect to the salt concentration and pH value using atomic force microscope (AFM). The forces were quantitatively converted by the Derjaguin-Landau-Verwey-Overbeek (DLVO) theory to the surface potential and charge density of surfaces. The converted-value dependence on the salt concentration and pH was described with the law of mass action, and the dependence was consistent with the theoretical prediction. It was found that the mercaptoundecanoic-acid layer had higher values for the surface charge densities and potentials than the $ZrO_2$ surfaces, which may be attributed to the ionized-functional-groups of the mercaptoundecanoic-acid layer.

Properties of Dental CAD/CAM Zirconia (CAD/CAM 지르코니아 재료의 특성)

  • Bae, Tae-Sung
    • The Journal of the Korean dental association
    • /
    • 제49권5호
    • /
    • pp.260-264
    • /
    • 2011
  • Zirconia ($ZrO_2$) is a crystalline dioxide of zirconium. Dental zirconia blocks for CAD/CAM are usually fabricated with powders of tetragonal zirconia polycrystals (TZP) stabilized with 3mol% yttria. Because of its mechanical properties similar to those of metals and color similar to tooth, it is evaluated to attain the two purposes at a time, strength and aesthetic in prosthetic dentistry. The ability of transformation of Y-TZP from tetragonal to monoclinic helps to prevent crack propagation and contributes the increase of strength and fracture toughness. Two different types of blocks, soft and hard, are used to prepare the zirconia frameworks. The fuzzy-sintered block is difficult in machining, so pre-sintered soft 3Y-TZP block is usually used to mill by computer aided machining.

Ionio conductivity of solid solution ceramics in the system of $CaO-Y_{2}O_{3}-ZrO_{2}$ Prepared by SHS

  • Soh, Deawha;Korobova, N.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.211-214
    • /
    • 2001
  • The undesirable phase transformation of zirconium dioxide at high temperatures can be eliminated by stabilization of the cubic phase with an addition of a selected alkaline earth or rare-earth oxide. In this paper the ionic conductivity of cubic solid solutions in the stabilized ZrO$_2$ by CaO-Y$_2$O$_3$ system was examined. The higher ionic conductivity appears to be related to lower activation energy rather than to the number of oxygen vacancies dictated by composition. Those compositions of highest conductivity lie close to the cubic-monoclinic solid-solution phase boundary. Conductivity temperature data are presented that indicate a reversible order-disorder transition for Zr$_2$2-Y$_2$O$_3$cubic solid solutions containing 20 and 25 mole % $Y_2$O$_3$.

  • PDF

임상가를 위한 특집 1 - 지르코니아의 역사 및 이론적 배경

  • No, Gyeong-Ho;Ha, Seung-Ryong;Kim, Seong-Hun
    • The Journal of the Korean dental association
    • /
    • 제47권12호
    • /
    • pp.798-803
    • /
    • 2009
  • 지르코니아는 물리적 성질이 금속과 가장 가까운 세라믹이며, 색상이 치아와 비슷하여 치과분야에서 사용빈도가 증가하고 있는 재료이다. 지르코니아는 zirconium dioxide 결정체로서, 1975년 Garvie가 'ceramic steer' 이라고 명명하였듯이 기존의 세라믹과 비교하여 뛰어난 물성을 지니고 있다. 즉, 높은 내열성과 낮은 열전도도, 산성에서 알카리성까지 이르는 내화학 안정성, 낮은 열팽창성, 높은 강도 및 경도, 내마모성을 가지고 있기 때문에 이전부터 공업용 재료로 넓게 시용되어 왔다. 지르코니아의 상변 이를 이용한 toughening방법이 Garvie에 의해 제시됨으로서 세라믹의 최대 단점인 취성은 어느 정도 극복할 수 있게 되었고 이를 계기로 금관 및 계속가공 의치, 임플란트 지대주, 인레이, 온레이 등 치과의 여러 분야에 지르코니아를 적용할 수 있게 되었다. 최근에는 임플란트 매식체에 있어서도 그 적용을 시도함으로서 심미치과치료에 있어서 중요한 부분으로 자리 잡고 있다. 현재 지르코니아는 치과용 세라믹 중에서 가장 높은 기계적 물성을 보이기 때문에 구치부 에서의 사용 가능성이 시도되고 있으며, 코어의 두께를 감소시킴으로써 보철 술식에서 필요한 강도 및 심미성 두 마리 토끼를 잡을 수 있도록 많은 연구가 이루어지고 있다. 이에 지르코니아의 역사 및 이론적 배경에 대하여 알아보고자 한다.

  • PDF

The Fabrication of the $ZrO_2$ Thin Film by Chemical Vapor Deposition and the Effect of the Reaction Parameters on the Deposition Characteristics (화학증착법에 의한 $ZrO_2$ 박막의 제조 및 반응변수에 따른 증착특성)

  • 최준후;김호기
    • Journal of the Korean Ceramic Society
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 1991
  • Zirconium dioxide(ZrO2) thin films have been deposited by chemical vapor deposition technique involving the application of gas mixture of ZrCl4, and H2O into silicon wafers. The relationships between the deposition rate and various reaction parameters such as the deposition time, the gas flow rate, the deposition temperature, and the composition of reactant gases were studied. The film was identified as nearly stoichiometric monoclinic ZrO2. The apparent activation energy is about 19Kcal/mole at surface chemical reaction controlled region. The deposition rate is mainly influenced by the H2O-forming reacting between CO2 and H2.

  • PDF