• Title/Summary/Keyword: age of air

Search Result 756, Processing Time 0.03 seconds

Numerical Study on Indoor Air Quality Based on Age of Air for the Underfloor Air Distribution System (수치해석을 이용한 바닥공조 시스템의 공기환경 평가)

  • Pang, Seung-Ki;Ahn, Hye-Rin;Lee, Won-Keun;Moon, Ki-Sun;Kim, Jongryul;Lee, Kwang-ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.40-46
    • /
    • 2016
  • In order to improve air quality of indoor environment, studies of the underfloor air distribution (UFAD) system for application in buildings are actively in progress based on temperature and air flow distribution. However, although the age of air is the major evaluation parameter, there has been very little study on this parameter for the UFAD system. In this study, we investigated the age of air to reach the air diffuser, which is installed at the bottom of the interior by the UFAD system. Computational fluid dynamics simulations showed no regular pattern to the maximum value of the age of air in accordance with air flow rate and the velocity at air diffuser. These factors can be deduced from air movement by considering that air emitted from air conditioners was rotated according to the bottom shape of the floor, and then, the age of air in the rotation center was increased. The average age of air of internal interior was reduced considerably as the flow velocity at the underfloor air diffuser was increased from 0.5 m/s to 1.0 m/s However, the age of air was not substantially affected with change in the air volume. Moreover, when the flow velocity at the underfloor air diffuser was higher than 1.0 m/s, the age of air showed no significant difference with change in air volume or height of measurement. These results imply that indoor air quality is more substantially influenced by flow velocity than air volume, and the appropriate flow velocity is 1 m/s or more.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Study on the Relationship between Indoor $CO_2$ Concentration and Local Mean Air-age in the Lecture Room with System Air-conditioner and Ventilation Unit for Cooling Loads (냉방시 시스템에어컨과 환기유닛 적응 강의실에서 실내 $CO_2$ 농도와 국소평균공기연령 연구)

  • Jang Jae-Soo;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.736-745
    • /
    • 2005
  • This study is undertaken to evaluate the relationship between the indoor $CO_2$ concentration and the local mean air-age in the lecture room with the occupants. We conducted the experiments to examine the indoor $CO_2$ concentration and the local mean air-age with respect to the supply airflow of the ventilation system and the discharge angle and air-flow of the system air conditioner. Through the experiments, we found out that indoor $CO_2$ concentrations calculated by the prediction equation of Seidel are about 350 ppm lower than those measured by the experiments. The indoor $CO_2$ concentration is not related with the air-flow and the discharge angle of the system air-conditioner, but with the ventilation airflow. From the numerical calculation, the indoor $CO_2$ concentration is not related with the ventilation effectiveness, but strongly with the local mean air-age. In case of our model, the indoor $CO_2$ concentration is likely to fall within the acceptable air quality when the local mean air-age is averagely predicted under 400 seconds.

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Analysis of the Local Air-Change Effectiveness by Field Measurement (실험을 통한 환기시스템의 국소적 환기효율 분석)

  • Choi, Younhee;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.63-67
    • /
    • 2017
  • The purpose of this study is to analyze the Age of Air and the Local Air-change Effectiveness of by field measurement. The indexes of Age of Air and Local Air-change Effectiveness are used to analyze the local ventilation effectiveness of multiple locations and are mainly evaluated using the computational fluid dynamics (CFD) method. In this study, measurement of the Local Air-change Effectiveness was based on ASHRAE 129. The performance of Local Air-change Effectiveness and the dependence of the outlet location on Local Air-change Effectiveness were analyzed. The results showed that a greater air-change rate (ACH) may not guarantee better local ventilation effectiveness.

NUMERICAL STUDY ON PERFORMANCE ASSESSMENT AND INSTALLATION CONDITIONS OF AN AUTOMOTIVE AIR CLEANER (자동차용 공기청정기의 성능 평가 및 설치 조건 도출을 위한 수치해석적 연구)

  • Lee, Y.H.;Seo, J.W.;Park, J.H.;Choi, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.263-270
    • /
    • 2010
  • In this study, an air cleaner is considered to improve comfort, safety, and health of automobile passengers. The performance and installation conditions of the air cleaner have been studied to investigate their effects on the air quality in the cabin room using numerical analysis. A five-passenger sedan and a seven-passenger minivan that have comparatively large indoor volume have been considered. The distributions of the local mean age and the volume averaged age of indoor air are calculated according to the variation of the placement and the air flow of the air cleaner. In addition, a decrease of contamination concentration, especially VOCs(volatile organic compounds), by the air cleaner is numerically analyzed with time-accurate unsteady calculation to quantify the effect of the air cleaner on the indoor air quality. As a result, the effective installation and operation conditions of the air cleaner for the automobile cabin room could be suggested.

  • PDF

Regeneration of Pinus densiflora Commuity around that Yeocheon Industrial Complex Disturbed by Air Pollution (대기오염으로 교란된 여천공단 주변 소나무군락의 재생)

  • Lee, chang Seok
    • The Korean Journal of Ecology
    • /
    • v.16 no.3
    • /
    • pp.305-316
    • /
    • 1993
  • Stands profiles, yearly changes in growth of annual rings, age and diameter structure, and spatial distribution pattern of individuals in the Pinus densiflora stands around the Yeocheon industrial complex were investigated. Growth of annual ring in Pinus densiflora, which survived when vegetation of this area was damaged by air pollutants, was suppressed for about 10 years since 1974 when factories in this area began to operate, but since then such suppressed growth tended to be recovered. It was supposed that the suppresed growth was originated from air pollution and that improvement of growth since the suppressed period was due to the release from competition with them by death of neighbouring trees and the resuction of the amount of air pollutants. Physiognomy of Pinus densiflora stands showed mosaic pattern composed of different patches. Spatial distribution pattern of individuals an stand profiles were similar to those of Pinus densiflora stands regenerated after natural and artificial disturbances. In an age distribution diagram, age of Pinus densiflora population ranged from 1 to 33 years, Among these individuals were recrited corresponded to the suppresed period of growth of annual ring in Pinus densiflora survived when the vegetation was damaged by air pollution. On the other hand, from the result of analysis of frequency distribution diagram of diameter, it was postulated that even if whis Pinus densiflora community can be maintained as it is for the time being, it might be changed to Quercus community with the lapse of time.

  • PDF

Estimation of the Effects of Air Pollutants on Tree Ring Growth in Black Pines (Pinus thunbergii)

  • Song, Young-Joo;Kim, Yoon-Dong;Choi, Kee-Ryong
    • Journal of Ecology and Environment
    • /
    • v.32 no.2
    • /
    • pp.109-113
    • /
    • 2009
  • Tree-ring width analysis has been used to assess the effects of air pollution on tree growth around industrial complexes. Our study was conducted to elucidate the effect of air pollutants on annual ring growth in black pines (Pinus thunbergii) of age 41$\sim$48 years around Ulsan Metropolitan City. The growth data were analyzed by multiple regression and the results are as follows: 1. The annual ring increment of black pines increased with tree age until age 40 years and then decreased gradually after age 40 years. 2. The increment of annual ring width of black pines was affected more by precipitation and evapotranspiration than air temperature. An annual ring decline appeared in the years 1968$\sim$1983, when annual ring indices below zero were observed. Decreased annual ring growth during this period may have been due to air pollution. 3. The heavy metal with the strongest effect on annual ring growth of black pines in the experimental stand was lead (Pb). The concentration of lead in the stand was estimated as over 6 ppm. 4. The technique of tree-ring width analysis may be useful for estimation of the extent of pollution in forest areas near industrial complexes.

Air Pressure Regulation in Air Bladders of Ascophyllum nodosum(Fucales, Phaeophyceae)

  • Brackenbury, Angela M.;Kang, Eun-Ju;Garbary, David J.
    • ALGAE
    • /
    • v.21 no.2
    • /
    • pp.245-251
    • /
    • 2006
  • Diurnal and age-related changes in air pressure were measured in air bladders of Ascophyllum nodosum from the Atlantic coast of Nova Scotia. Exterior and interior bladder volumes vary significantly with 4 and 6 y bladders being about 40% larger than 2 y bladders (p < 0.01). Freshly collected bladders yielded a mean pressure of 40.8 ± 6.5 cm H2O. Overnight (20 h) dark treatment at 15°C generated pressure reductions by 80% in 2 y bladders but only by about 30% in 4 and 6 y bladders. Furthermore, in 2 y bladders 8 out of 11 bladders were reduced to atmospheric pressure. Pressure losses were inversely related to pressure recovery after 2.5 h in natural daylight, but after 5 h in daylight there was no significant difference in pressure within the age groups. Even under 25% of full illumination, bladders inflated to full pressure after 5 h. The results show that differences in bladder age and bladder wall thickness have roles in diurnal patterns of bladder inflation and deflation. These results confirm that bladder inflation is based on photosynthetic O2 production and not on partial pressures of O2 in the surrounding medium as was suggested for Sargassum. Chemical analyses of fluid recovered after the interior of bladders were washed with saline showed no evidence for the occurrence of surfactant that might be responsible for maintaining the air-liquid interface.

An Investigation on Estimation of the Compressive strength by P Type Schmidt Hammer (P형 슈미트햄머에 의한 압축강도 추정에 관한 검토)

  • 김기정;이용성;이백수;윤기원;최영화;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.11-15
    • /
    • 2002
  • This study is intended to analyze the relationship between the rebound value of P type schmidt hammer and the compressive strength for a quality control of concrete. According to the results, the compressive strength of standard curing specimen increases in proportion to age, but that of air curing specimen hardly increases after 28 days. The rebound value of P type schmidt hammer, however, increases due to carbonation of concrete in air curing specimen. The correlativity between the rebound value and the compressive strength is very favorable in the case of standard curing specimen, but drops remarkably in the case of air curing specimen. Thus, as application of age coefficient is required for exact estimation of the compressive strength, the age coefficient is derived from this study. The age coefficient of P type schmidt hammer is higher at the age of 3 and 7days, and drops significantly, compared with the age of 28days. And it is lower before 28days than that of N type schmidt hammer suggested in Japan, and shows the similar tendency after 28days.

  • PDF