• 제목/요약/키워드: arc-discharge

검색결과 371건 처리시간 0.031초

Investigation of an Arc-induced Long Period Fiber Grating Inscribed in a Photonic Crystal Fiber with Two Large Air Holes

  • Kim, Sun-Duck;Kim, Gil-Hwan;Hwang, Kyu-Jin;Lim, Sun-Do;Lee, Kwan-Il;Kim, Sang-Hyuck;Lee, Sang-Bae
    • Journal of the Optical Society of Korea
    • /
    • 제13권4호
    • /
    • pp.428-433
    • /
    • 2009
  • A photonic crystal fiber with two large air holes outside the holey cladding region is fabricated to induce an effective long periodic grating (LPG) in the core by an electric arc discharge. We believe that the two large air holes lead to the asymmetric perturbation in the core under the electric arc discharge, thereby introducing the coupling to the first higher-order mode. The transmission characteristics of the PCF with the LPG for the external perturbation such as strain, curvature, and temperature are also investigated. It was found that the shift of resonance peak in the transmission spectrum depends on the bending direction. The curvature of 8.55 $m^{-1}$ results in the center wavelength shifts of 1.8, 4.3, and 11 nm for a vertical, diagonal, and horizontal direction of the curvature to the large air-hole alignment, respectively.

염색폐수 처리를 위한 하이브리드 플라즈마 특성연구 (A Study on the Characteristics of Hybrid-Plasma Torch for Dyeing Wastewater Treatment)

  • 정장근;윤석현;박재윤;김상돈
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.75-81
    • /
    • 2008
  • 본 논문은 플라즈마를 이용한 수처리 연구를 수행하였다. 이 연구에 사용한 수중플라즈마 토치는 상당한 전력의 절감을 가져올 수 있기 때문에 경제적인측면과 에너지효율면에서 뛰어난 결과를 나타내었다. 수중에서 일어나는 스트리머방전과 아크방전 현상을 면밀히 조사하여 비교하였고, 또한 염색페수를 플라즈마로 처리하였을 시의 색도제거율과 용존오존, 과산화수소와의 상관관계를 알기위해 표본화하고 분석하였다. 이에 플라즈마토치에는 선택적인 산화반응이 다소 있긴 하지만, 플라즈마화학반응에 의한 $H_2O_2$$O_3$의 성장이 아크방전 보다 스트리머방전시 더 효과적으로 촉진된다는 것을 알 수 있었다. 따라서 스트리머방전이 아크플라즈마 토치에 비해 더 효율적인 플라즈마 화학반응을 일으킬 수 있는 환경을 만들어주므로, 수처리에 있어서 스트리머플라즈마토치가 더 적합하였다.

GIS를 이용한 환경오염의 예측 모델 (GIS- Based Predictive Model for Measure of Environmental Pollutant)

  • 이자원
    • 한국지역지리학회지
    • /
    • 제14권2호
    • /
    • pp.114-125
    • /
    • 2008
  • 본 연구는 GIS를 사용하여 메사추세츠 동부의 보스턴시에 위치한 넷폰셋 강 유역의 수질 오염 정도를 측정하기 위한 것이다. 관련된 오염물질로써 CDOM을 축출하여 지표면의 유수가 다양한 토지이용과 연계되어 바닷물로 흘러들어가는 과정을 예측하고 이를 모형화하게 된다. CDOM의 축출과 분석은 관련학과의 도움을 받아 그 결과를 산출하고, 이를 GIS의 공간분석 기법을 이용하여 지역과 지형적인 특성에 따라 오염물질이 전해지면서 토지이용에 어떠한 변화가 생기는지를 관측하게 된다. 수계의 형성과 강의 흐름, 그리고 토지이용 자료가 연구를 위해 분석 자료로 사용되었고, ArcGIS 9.2를 사용, 공간분석 기법을 통해 하위 분수계와 유동점, 토지이용 구획을 산출하게 된다. 이는 GIS 기법이 지형분석과 오염물질의 이동을 분석하는데 어떻게 활용될 수 있는지를 고찰하는 것으로써 의미있는 연구가 될 것이다.

  • PDF

방전신호 검출에 의한 히팅 케이블의 상태감시기술 (Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal)

  • 김동언;김남훈;임승현;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제34권2호
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

유전체 장벽 방전 플라즈마의 Monostatic 레이다 단면적 측정 (Monostatic RCS Measurement for Dielectric Barrier Discharge Plasma)

  • 이현재;정인균;하정제;신웅재;양진모;이용식;육종관
    • 한국전자파학회논문지
    • /
    • 제27권3호
    • /
    • pp.246-252
    • /
    • 2016
  • 본 논문에서는 유전체 장벽 방전(dielectric barrier discharge: DBD) 플라즈마에 의한 monostatic RCS 감소 특성을 측정하였다. Monostatic 레이다 단면적(radar cross section: RCS) 교정을 위하여 서로 다른 크기의 금속 평판을 사용하여 산란계수(scattering parameter)를 측정하였고, 그 결과 0.4 dB 이내의 오차를 보였다. DBD 플라즈마에 의한 monostatic RCS 감소 특성을 측정하기 위해 DBD 플라즈마 발생기 뒤에 금속 평판을 배치하였다. 금속 평판과 플라즈마 발생기 사이에 아크 방전(arc dischrage)이 일어나는 것을 방지하기 위해 금속 평판과 DBD 플라즈마 사이의 간격을 띄워 측정을 진행하였다. 그 결과 7.4 GHz에서 monostatic RCS가 최대 약 3 dB 감소하였다.

SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석 (Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation)

  • 신한신;김남훈;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

압연이 Ni-MH 2차전지용 금속수소화물 전극의 충·방전 특성에 미치는 영향 (The Effect of Rolling on the Charge-Discharge Characteristic of Metal Hydride Electrode for Ni-MH Secondary Battery)

  • 박원;장상민;최승준;노학;최전;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.165-171
    • /
    • 1996
  • The effect of rolling on the charge-discharge property was studied for metal hydride negative electrode. $(LM)Ni_{3.6}Al_{0.4}Co_{0.7}Mn_{0.3}$(pleateau pressure : below 1 atm at room temperature, volume expansion : 9%, entalpy : $8.7kcal/molH_2$) alloy was prepared by arc melting, and then it was coated with various copper weight percent. The copper coated alloys were then rolled with the different reduction ratio. From the results, it was found that the maximum discharge capacity increased with increasing reduction ratio, and 15wt% copper coated sample shows the highest discharge capacity, 324mAh/g, after rolling with 30% reduction ratio. In view of cycle life for the negative electrode, the 15wt% copper coated electrode which was rolled with 13% reduction ratio showed the longest cycle life compared with other electrodes.

  • PDF

전력용 변압기 초음파 측정시스템 적용 (Application of the Ultrasonic Detection System for the Power Transformer)

  • 권동진;구교선;김재철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.553-557
    • /
    • 2005
  • This paper describes the application results of an ultrasonic detection system for the power transformer. The ultrasonic detection system with 6 sensors was applied to detect partial discharge in a 154kV transformer with a dangerous levels of $C_{2}H_{2},\;C_{2}H_4$ and $CH_{4}$ gases. The ultrasonic detection tests were carried out 2 times, respectively, to confirm the existence and location of the partial discharge in the transformer. As a result of internal inspection, the arc trace between the pressure ring and core due to the partial discharge was found at the estimated position based on the amplitude and arriving time of the ultrasonic signals. Therefore, it was verified that the ultrasonic detection system is effective as a preventive diagnosis method for the power transformer. Also, the reliability of the ultrasonic detection system in detecting partial discharges in the transformer was also confirmed. It is expected, therefore, that the ultrasonic detection system will have beneficial effects on applications and verifications in detecting partial discharges for the power transformer.

증착방법에 따른 Al 피막의 증착율 및 증기분포에 관한 연구 (Study on the deposition rate and vapor distribution of Al films prepared by vacuum evaporation and arc-induced ion plating)

  • 정재인;정우철;손영호;이득진;박성렬
    • 한국진공학회지
    • /
    • 제9권3호
    • /
    • pp.207-215
    • /
    • 2000
  • 진공증착 및 이온플레이팅 방법을 이용하여 냉간 압연된 강판상에 알루미늄피막을 형성시킨 후, 증발율 및 증기분포 변화를 측정하고 각 증착방법에서의 증발율에 따른 증기분포 변화를 비교 및 검토하였다. 본 실험에서의 이온플레이팅은 증발원 근처에 이온화 전극을 설치하는 방법으로 고전류 아크방전을 유도하여 $10^{-4}$ Torr 이하에서도 기존의 이온플레이팅에 비해 높은 이온화율을 얻을 수 있는 아크방전 유도형 이온플레이팅(Arc-induced ion Plating; AIIP) 방법을 이용하였다. 전자빔을 이용하면서 알루미나 크루시블을 사용하여 알루미늄을 증발시킬 경우 분당 2.0 $\mu\textrm{m}$이상의 높은 증발율을 얻을 수 있었으며, 이온플레이팅의 경우 이온화된 증기의 상호작용에 따른 산란 효과로 증발율이 다소 낮아짐을 알 수 있었다. $cos^{n/\phi}$로 이루어지는 증기분포의 결정인자(n)의 값이 진공증착의 경우는 1에 근접하는 것으로 나타났고 AIIP의 경우는 2 또는 그보다 더 큰 값으로 이루어지는 것을 확인하였다. 이로부터 이온플레이팅의 경우 이온화율 또는 기판 바이어스 전압의 효과가 다른 조건에 비해 증기분포에 더 크게 영향을 미치는 것을 확인할 수 있었다.

  • PDF

Modification of DC Flashover Voltage at High Altitude on the Basis of Molecular Gas Dynamics

  • Liu, Dong-Ming;Guo, Fu-Sheng;Sima, Wen-Xia
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.625-633
    • /
    • 2015
  • The effect of altitude on thermal conduction, surface temperature, and thermal radiation of partial arc was investigated on the basis of molecular gas dynamics to facilitate a deep understanding of the pollution surface discharge mechanism. The DC flashover model was consequently modified at high altitude. The validity of the modified DC flashover model proposed in this paper was proven through a comparison with the results of high-altitude simulation experiments and earlier models. Moreover, the modified model was found to be better than the earlier modified models in terms of forecasting the flashover voltage. Findings indicated that both the thermal conduction coefficient and the surface thermodynamics temperature of partial arc had a linear decrease tendency with the altitude increasing from 0 m to 3000 m, both of which dropped by approximately 30% and 3.6%, respectively. Meanwhile, the heat conduction and the heat radiation of partial arc both had a similar linear decrease of approximately 15%. The maximum error of DC pollution flashover voltage between the calculation value according to the modified model and the experimental value was within 6.6%, and the pollution flashover voltage exhibited a parabola downtrend with increasing of pollution.