• Title/Summary/Keyword: arc-discharge

Search Result 371, Processing Time 0.04 seconds

Study on Restriking Transient Voltage Characteristics and Waveform Patterns of Planar Copper-Carbon Electrodes using Forms (평면형 구리 - 탄소 전극의 형태별 재기전압 특성 및 파형 패턴에 관한 연구)

  • Lim, Jong-Min;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.1-6
    • /
    • 2020
  • In this study, the authors measured voltage and current waveforms in real time during a serial arc discharge. The analysis results of the arc discharge radiation patterns exhibited intermittent discharge, arc growth, creation of a heat generating area, occurrence of plume, and formation of a red heat area, which proceeded in that order. When the serial arc discharge was introduced, the current and voltage waveforms exhibited periodicity as sine waves. It was also observed that a restriking transient voltage occurred when the waveform changed from positive (+) to negative (-) and vice versa. When the discharge proceeded, the amount of heat generated for 1 s and 600 s was approximately 0.317 mJ, and 190 mJ, respectively. The duration of the short circuit was approximately 1.66 ms, and in the case of the voltage waveform, it was evident that the electric potential increased to 49.9 V in the same cycle. Furthermore, when the discharge proceeded, the effective value (RMS value) of the current was approximately 1.72 A with a maximum current of approximately 2.53 A, whereas the effective value of the voltage was approximately 42.8 V with a maximum of approximately 208 V.

Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges (코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석)

  • Jo, Hyang-Eun;Jin, Chang-Hwan;Park, Dae-Won;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

Development of Carbon Nanotubes and Polymer Composites Therefrom

  • Jain, P.K.;Mahajan, Y.R.;Sundararajan, G.;Okotrub, A.V.;Yudanov, N.F.;Romanenko, A.I.
    • Carbon letters
    • /
    • v.3 no.3
    • /
    • pp.142-145
    • /
    • 2002
  • Multiwall carbon nanotubes (MWNT) were produced using the arc-discharge graphite evaporation technique. Composite films were developed using MWNT dispersed in polystirol polymer. In the present work, various properties of the polymeric thin film containing carbon nanotubes were investigated by optical absorption, electrical resistivity and the same have been discussed.

  • PDF

Interruption Controller Design of Arc current With Custom Electric Source (아크의 방전에 따른 전기안전에 미치는 영향)

  • Ban, Gi-Jong;Lim, Seung-Ha;Won, Young-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1283-1286
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

Conductive and Mechanical Properties Study of Ti-doped DLC (ta-C:Ti) Film on Semiconductor Probe through Taguchi Bobust Design (다구찌 강건 설계를 통한 반도체 Probe상 Ti 도핑된 DLC(ta-C:Ti) 코팅 막의 전도성 및 기계적 물성 연구)

  • Kim, Do-young;Shin, Jun-ki;Jang, Young-Jun;Kim, Jongkuk
    • Tribology and Lubricants
    • /
    • v.38 no.6
    • /
    • pp.274-280
    • /
    • 2022
  • There is a problem that semiconductor probe pin has a short lifespan. In order to solve this problem, Ti having excellent conductivity was doped to tetrahedral amorphous carbon (ta-C) having excellent hardness and abrasion resistance. This experiment was planned through the Taguchi robust design to determine the effect of the control factor of the ta-C:Ti coating film. The effect and contribution of control factors such as Unbalanced Magnetron Sputter(UBM) discharge current, arc discharge current, temperature, and bias voltage on ta-C:Ti characteristics were analyzed from the perspective of electrical and mechanical characteristics. The UBM discharge current was set to 4, 6, and 8 A. The main control factor of thickness and resistance is the UBM discharge current, and the thickness increased and the resistance decreased as the current increased. The decrease in resistance is due to the increase in the Ti content of the ta-C:Ti coating film. The arc discharge current was set to 60, 80, and 100 A. The main control factor of hardness and wear is the arc discharge current, and as the current rises, the hardness increases and the wear area decreases. This is due to the increased ta-C content of the ta-C:Ti coating film. Since resistance and wear are important for Probe Pin, the optimal level is set from the perspective of resistance and wear and a confirmation experiment is conducted.

A Basic Study on the Discharge of a Rod-to-Rod Microgap in the Pure Water (수중(水中) 미소(微少) 봉대봉(棒對棒) 전극간(電極間)의 방전현상(放電現象) 기초연구(基礎硏究))

  • Moon, Jae-Duk;Lee, Dae-Hee;Kim, Jin-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.918-921
    • /
    • 1992
  • A basic study on the discharge phenomenum of rod-to-rod microgap in the deionized water has been investigated with emphasis on the microgap spacing. The I-V charateristics for the case of ac and dc applied voltages had 3 different regions, a low conduction ohmic region, a medium conduction corona discharge region, and a high conduction arc discharge region. The corona discharge in the deionized water for the case of ac and de applied voltages had no different from the those in the air. But the arc discharge in the water occurred pulsative with sound which, however it is not clear, would be encounted due to the influences from the low temperature of the ambient water, vast of electrolytic generated electronegative gases(e.g. $O_2$, OH, O) and water molecules($H_2O$), and the space charge effects near the rod in the microgap from the ions of $H^+$, $OH^-$, $O_2^-$, etc, whose mobilities in the water are originally very low.

  • PDF

AFCI algorithm design for electrical fire protection (전기화재 방지를 위한 AFCI 알고리즘 설계)

  • Ban, Gi-Jong;Choi, Sung-Dai;Nam, Moon-Hyun;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1769-1770
    • /
    • 2006
  • Arc Fault is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional interrupter does not have the arc current interrupt function. Hence, Arc fault circuit interrupter controller is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

A Study of Arc Detection at DC Power System (직류 시스템에서의 아크 검출에 관한 연구)

  • Ban, Gi-Jong;Kim, Jin-Woo;Won, Young-Jin;Lim, Sung-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.461-462
    • /
    • 2007
  • DC Arc is an electric discharge which is occurred in two oppolsite electrode when system operating with DC current appliance. In this paper, DC arc detection system is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire of dc system. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

Forming the Are at Opening contacts and Arc Extinction by External Magnetic Force (접점 개방시 아크 형성과 외부자계에 의한 효과적인 아크 소호)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Jun-Ho;Lee, Hwa-Su
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.699-701
    • /
    • 2003
  • This paper compare the Townsend theory with the Molten metal bridge theory of Holm for the arc discharge at opening contacts. And we measured the arc voltage at opening contacts of the 3 types arc extinction unit used in DC magnetic contactor. So, we sure that the molten metal bridge contributes to form the arc. By the experiment of the 3 types arc extinction unit, we know that the magnetic force acting on the arc doesn't effect forming arc but contribut the arc extinction.

  • PDF