• Title/Summary/Keyword: autogenous shrinkage

Search Result 174, Processing Time 0.028 seconds

Autogenous Shrinkage of Concrete Containing Blast-Furnace Slag (고로 슬래그를 함유한 콘크리트의 자기 수축)

  • 이회근;권기헌;이광명;김규용;손유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.417-420
    • /
    • 2003
  • Concrete with low water to binder ratio (W/B) is prone to large autogenous shrinkage. Early age cracking of concrete would be caused by tensile stress induced by large autogenous shrinkage under restrained condition. Therefore, it is necessary to measure autogenous shrinkage to control the early age cracking of concrete. An objective of this study is to investigate the effects of W/B and blast furnace slag (BFS) on autogenous shrinkage of concrete. Autogenous shrinkage of concrete with various W/B ranging from 0.42 to 0.27 and BFS contents of 0, 30 and 50% were measured. Test results show that the autogenous shrinkage of concrete increases as the W/B decreases, and all BFS concretes showed larger autogenous shrinkage than OPC concretes with the same W/B. Moreover, the higher BFS content, the larger autogenous shrinkage.

  • PDF

A Study on the Creep and Autogenous Shrinkage of High Performance Concrete with Expansive Additive and Shrinkage Reducing Admixtures at Early Age

  • Park, Sun-Gyu;Noguchi, Takafumi;Kim, Moo-Han
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.2E
    • /
    • pp.73-77
    • /
    • 2006
  • This paper shows a study of the efficiency of expansive additive and shrinkage reducing admixture in controlling restrained shrinkage cracking of high performance concrete at early age. Free autogenous shrinkage test of $100{\times}100{\times}400mm$ concrete specimens and simulated completely-restrained test with VRTM(variable restraint testing machine) were performed. Creep and autogenous shrinkage of high-performance concrete with and without expansive additive and shrinkage reducing admixture were investigated by experiments that provided data on free autogenous shrinkage and restrained shrinkage. The results showed that the addition of expansive additive and shrinkage reducing admixture effectively reduced autogenous shrinkage and tensile stress in the restrained conditions. Also, it was found that the shrinkage stress was relaxed by 90% in high-performance concrete with and without expansive additive and shrinkage reducing admixtures at early age.

Autogenous shrinkage of ultra high performance concrete considering early age coefficient of thermal expansion

  • Park, Jung-Jun;Yoo, Doo-Yeol;Kim, Sung-Wook;Yoon, Young-Soo
    • Structural Engineering and Mechanics
    • /
    • v.49 no.6
    • /
    • pp.763-773
    • /
    • 2014
  • The recently developed Ultra High Performance Concrete (UHPC) displays outstanding compressive strength and ductility but is also subjected to very large autogenous shrinkage. In addition, the use of forms and reinforcement to confine this autogenous shrinkage increases the risk of shrinkage cracking. Accordingly, this study adopts a combination of shrinkage reducing admixture and expansive admixture as a solution to reduce the shrinkage of UHPC and estimates its appropriateness by evaluating the compressive and flexural strengths as well as the autogenous shrinkage according to the age. Moreover, the coefficient of thermal expansion known to experience sudden variations at early age is measured in order to evaluate exactly the autogenous shrinkage and the thermal expansion is compensated considering these measurements. The experimental results show that the compressive and flexural strengths decreased slightly at early age when mixing 7.5% of expansive admixture and 1% of shrinkage reducing admixture but that this decrease becomes insignificant after 7 days. The use of expansive admixture tended to premature the setting of UHPC and the start of sudden increase of autogenous shrinkage. Finally, the combined use of shrinkage reducing admixture and expansive admixture appeared to reduce effectively the autogenous shrinkage by about 47% at 15 days.

Effect of mineral admixture on chemical shrinkage and autogenous shrinkage of cement paste (화학수축과 자기수축에 혼화재가 미치는 영향)

  • Park, Chung-Hoon;Choi, Hoon Jae;Kim, Baek-Joong;Yi, Chongku;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.156-157
    • /
    • 2013
  • As the chemical shrinkage and autogenous shrinkage of paste constitutes a large part of the shrinkage of high strength concrete, a good understanding of characteristics of chemical shrinkage and autogenous shrinkage is essential in order to understand chemical shrinkage and autogenous shrinkage of concrete. In this study, a preliminary study on effect of mineral admixture on chemical shrinkage and autogenous shrinkage of paste was compared.

  • PDF

An Experimental Study on Chemical and Autogenous Shrinkage of Cement-paste and Mortar (시멘트페이스트와 모르타르의 화학 수축과 자기수축 실험연구)

  • 조경래;박신일;최진영;전철송;임병호;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.687-692
    • /
    • 2002
  • The chemical shrinkage and the autogenous shrinkage have been determined experimentally for cement pastes incorporating different W/C ratio and different amount of the following addition: silica fume, fly ash and sand. The measurement method of the chemical shrinkage and autogenous shrinkage both were the volumetric technique. The silica fume has a effect of increasing the autogenous shrinkage while have a minor effect on the chemical shrinkage. The addition of fly-ash and sand both decreased the amount of chemical shrinkage and autogenous shrinkage.

  • PDF

Effect of Hydration Heat Evolution on Autogenous Shrinkage of High Strength Concrete (초기수화발열이 고강도콘크리트의 자기수축특성에 미치는 영향)

  • 정해문;도변박지;하야도륭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.95-100
    • /
    • 2003
  • The shrinkage of high strength/high performance concrete is very important property for the good working of a structure since it very often generates early age cracking due to thermal and autogenous shrinkage. Autogenous shrinkage occurs as a result of internal moisture depletion due to hydration and temperature-induced effects. The level of autogenous shrinkage occurring due to hydration also depends on temperature history at very early age. It is necessary that effect of temperature on autogenous shrinkage is investigated since the stress generated due to autogenous shrinkage is quantified. In this study, Effect of hydration heat evolution on autogenous shrinkage of high strength concretes with W/C=25-40% was investigated.

  • PDF

Prediction Model on Autogenous Shrinkage of High Performance Concrete (고성능 콘크리트의 자기수축 예측모델에 관한 연구)

  • Yoo, Sung-Won;Soh, Yang-Sub;Cho, Min-Jung;Koh, Kyung-Taek;Jung, Sang-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.97-105
    • /
    • 2006
  • The autogenous shrinkage of high-performance concrete is important in that it can lead the early cracks in concrete structures. The purpose of the present study is to explore the autogenous shrinkage of high-performance concrete with admixture and to derive a realistic equation to estimate the autogenous shrinkage model of that. For this purpose, comprehensive experimental program has been set up to observe the autogenous shrinkage for various test series. Major test variables were the type and contents of admixture and water-cement ratio is fixed with 30%. The autogenous shrinkage of HPC with fly ash slightly decreased than that of OPC concrete, but the use of blast furnace slag increased the autogenous shrinkage. Also, the autogenous shrinkage of HPC is found to decrease with increasing shrinkage reduction agent and expansive additive. A prediction equation to estimate the autogenous shrinkage of HPC with admixture was derived and proposed in this study. The proposed equation show reasonably good correlation with test data on autogenous shrinkage of HPC with mineral and chemical admixture.

Strength and Autogenous Shrinkage of High Strength Mortar Using Water Substituting Liquid

  • Han, Min-Cheol;Lee, Dong-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.538-546
    • /
    • 2011
  • This paper is to experimentally investigate the strength and autogenous shrinkage of high strength mortar with the 20 % of water?binder ratio(W/B). In this study, the water substituting liquid(WSL) was used including gasoline, light oil, lamp oil, edible oil, HFE, ethanol, methanol and acetone in order to explore changes in strength and autogenous shrinkage depending on WSL type and replacement. For fresh properties, the replacement of WSL did not affect the fluidity of mortar mixtures considerably, except for ethanol and methanol. However, the replacement of WSL resulted in a slight decrease in flexural and compressive strength. For autogenous shrinkage, the replacement of WSL led to reduce autogenous shrinkage, and especially, the replacement of edible oil led to reduce autogenous shrinkage significantly due to saponification between edible oil and cement.

Autogenous Shrinkage Stress in Reinforced Concrete Beams (철근콘크리트 보에서 자기수축응력)

  • 최익창;김대웅
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.101-106
    • /
    • 2003
  • This study is to capture autogenous shrinkage in reinforced concrete. The experiment was carried out on total 13 beams. The experiment parameters are a method of curing and reinforcement ratio. Autogenous shrinkage in reinforced concrete beam was experimentally measured. Also, the distribution of autogenous shrinkage and self stress on cross section in reinforced concrete beams were calculated. The experimental results showed that autogenous shrinkage of high strength concrete were significantly higher than that of nomal strength concrete.

  • PDF

Effects of Specimen Shape on Hydration Heat and Autogenous shrinkage at an early (시험체 형상에 따른 고강도 콘크리트의 수화열 및 자기수축 초기특성 분석)

  • Lee, Eui-Bae;Koo, Kyung-Mo;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.915-918
    • /
    • 2008
  • Hydration heat and autogenous shrinkage are generated essentially by the same hydration. Many researchers have studied the close relationship between hydration temperature and autogenous shrinkage but hardly any research has been undertaken to explain the specific numerical relation. In this study, early age properties of hydration heat and autogenous shrinkage of specimen whose section size was changed were analyzed, and relationship between hydration heat and autogenous shrinkage was investigated. In the results of the study, inner temperature and autogenous shrinkage increased as the section size increased. And rise and rise ratio of hydration temperature and autogenous shrinkage in hydration heating section and autogenous shrinking section are increased too. Temperature rise and autogenous shrinkage rise increased respectively, as hydration heating velocity and autogenous shrinking velocity increased. And autogenous shrinkage rise and autogenous shrinking velocity increased as hydration heating velocity increased.

  • PDF