• Title/Summary/Keyword: automatic valve

Search Result 158, Processing Time 0.031 seconds

Internal Flow Analysis and Structural Design in Plastic Automatic Control Valve for the Semiconductor Chemical Liquid (반도체 약액용 자동제어 플라스틱 밸브의 내부 유동해석)

  • Lee, Gyu-Hoon;Lee, Eung-Suk;Lee, Min-Ki;Kim, Jin-Su;Bae, Il-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.311-315
    • /
    • 2012
  • Diaphragm type noncontact automatic control valve is a valve for controling acidic PR(Photo Resist) liquid used in the semiconductor process. PR is photosensitive liquid that changes phases depending on light transmittance. PR is very toxic and expensive; the purpose of this paper is to address methods that prevent loss due to leaks. The design of noncontact precise automatic control valve is expected to play an important role in controlling fluid flow, therefore influencing energy conservation and environmental improvement. In this paper, diaphragm type automatic control valve's part design, assembly and simulation are introduced. Also, through the analysis of fluid flow the valve's internal velocity, pressure, and turbulent intensity are interpreted. This paper proposes to contribute to the improvement of the valve's performance.

Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder (LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.80-84
    • /
    • 2015
  • In this paper, the valves for a LPG gas cylinder have been investigated on the body height and weight by comparing design data between typical automatic shut-off vertical and newly developed horizontal valves. The height of an automatic shut-off horizontal valve is radically reduced by 41~42% compared with that of a typical automatic shut-off vertical valve. And, the body weight of a horizontal valve is also reduced by 29~40% compared with that of a vertical shut-off valve. This result is just achieved by a structural design modification from typical vertical valve to horizontal arrangement of various valve components.

Spring Length Effect on the Flow Capacity of automatic Flow-Temperature Control Valve (자동 정유량 온도조절밸브의 스프링 길이가 밸브 용량에 미치는 영향)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.174-177
    • /
    • 2003
  • The automatic temperature control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have simillar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the automatic flow-temperature control valve was developed. The perfromance of this control valve is effected by the catridge shape and spring length. The flow capacity of this control valve is obtained with the different shape of catridges and with change of spring length.

  • PDF

A Study on the Modeling and Optimization of Check Valve in Automatic Transmission (자동변속기내 체크밸브의 모델링 및 최적화 연구)

  • 송재수;정우진;김성원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.111-119
    • /
    • 1997
  • The operating characteristics of the check valve in the clutch piston of an automatic transmission have a great effect on the shifting performance. This paper addresses the modeling, dynamic analysis, and optimization of the check valve. It was found that the vortex causes a pressure drop, which is related to the rotating speed of the clutch piston, oil volume discharged from the check valve, and valve geometry. Maximizing the oil volume discharged, geometry of the check valve is optimized. The results can be used to design an improved check valve which provides a suitable oil pressure curves for achieving smoother shifting.

  • PDF

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

Development of Y Strainer Type Automatic Flow Rate Regulating Valve (Y 스트레이너형 자동 정유량 조절 밸브의 개발)

  • Yoon, Joon-Yong;Kwon, Woo-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve (공압밸브의 동적응답 특성측정 자동화 시스템 개발)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF

압력제어솔레노이드밸브를 이용한 직접구동 방식의 유압회로에 의한 자동변속기의 변속품질 향상에 관한 연구

  • 김정관;한명철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.505-508
    • /
    • 1995
  • This paper suggests new hydraulic circuit to control the pressure of clutches and brakes which has several advantages than conventional hydraulic circuit in automatic transmissions. In conventional hydraulic circuit, the pressures of all friction elements are controlled by only one pressure control valve and accumlators. So, controllable range is limited and it is unable to control the friction elements independently. Therefore, we can not do the fine control of timing between apply clutch and release clutch which is needed in clutch-to clutch shifting automatic transmissions. To overcome these faults, we designed the direct-acting hydraulic circuit where one pressure control valve and pressure control solenoid valve are allocated to each friction element and control that independently. Through this structural improvement of hydraulic circuit, we can achieve elaborate aontrol to clutch pressure. Specially, We can control the timing between apply clutch and release clutch delicately which is needed in clutch-to-clutch shifting.

  • PDF

Modeling and Parameter Estimation of Solenoid Valve in Automatic Transmission by the Least Square Method (최소자승법에 의한 A/T용 솔레노이드 밸브의 모델링 및 파라미터 평가)

  • 노형우;박상훈;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.98-104
    • /
    • 2003
  • Model structure of solenoid valve in the automatic transmission is determined as 5th order system by the signal error test. For determining parameter of the solenoid valve, parameters in time discrete model are searched by the least square method. By bilinear transform, we have found the model of solenoid valve in s domain. Afterward, experimental output data is compared with simulated output data by MATLAB having identified parameter. As the result, experimental data is agreed with simulated data very well.

Dynamic characteristic identification of PWM solenoid valve for automatic transmission (자동변속기용 펄스폭변조 솔레노이드 밸브의 동특성 식별)

  • Jung, Gyu-Hong;Cho, Baek-Hyun;Lee, Kyo-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1636-1647
    • /
    • 1997
  • As most of today's automatic transmissions in passenger car adopt a electro-hydraulic control system, the role of electronically controlled solenoid valves occupies an important position and it is essential to predict solenoid transient characteristics in order to design and evaluate the performance of the hydraulic control system. However, in general, both the magnetic and electrical parameters f the solenoid system are hardly known and it is not easy to model this section with moderate complexity although mechanical system could be developed using the classical second order system. This paper presents a dynamic modelling technique of a solenoid valve, that is controlled by pulse width modulation for an automatic transmission, in terms of system identification theory. In nonlinear computer simulation, it is shown that the identified systems which produce magnetic force to input duty cycle for various excitation signals predict the static and dynamic performance very well near the operating point and in experiment conducted to confirm the validity of identification theory for PWM solenoid valve, we find that there is a good agreement between the experimental data and simulation result. Hence, this model can be utilized in the development of pressure control system with PWM solenoid valve.