• Title/Summary/Keyword: blood glucose

Search Result 3,191, Processing Time 0.03 seconds

The Effects of the Application of a Glucose Control Protocol on Glycemia and Glucose Variability in Critically Ill Cardiothoracic Surgery Patients (혈당 조절 프로토콜 적용에 따른 흉부외과 중환자의 혈당 조절 상태와 혈당 변동)

  • Yoo, Hye Jin;Lee, Nam Ju;Lee, Soon Haeng
    • Journal of Korean Critical Care Nursing
    • /
    • v.8 no.2
    • /
    • pp.1-12
    • /
    • 2015
  • Purpose: The study sought to determine the state of blood glucose control, and the consequent clinical effects and variation in blood glucose level, of adult patients admitted to intensive care units following cardiothoracic surgery by comparing the blood glucose levels before and after the application of a blood glucose control protocol. Methods: The protocol was developed by modifying and supplementing the Yale protocol, and was first used in 2012. The resulting blood glucose data of an experimental group (n = 314), to which the blood glucose control protocol had been applied, and a control group (n = 347), whose blood glucose levels had been controlled according to physicians'prescriptions without the protocol, were collected through the medical records. Results: The target blood glucose ratio increased significantly in the experimental group, and the low blood glucose ratio decreased significantly in the experimental group. The two groups exhibited a significant difference (p < .001) in the degree of variation in the blood glucose levels. The duration of the use of a ventilator was significantly reduced in the experimental group (p < .001). Conclusion: It is expected that the protocol can be used for the safe and effective control of critically ill cardiothoracic surgery patients' blood glucose levels.

The Nutritional Status of Middle Aged Korean Men Exhibiting Impaired Glucose Tolerance and Their Blood Lipid Profile (내당능장애 가능성이 있는 중년 남성의 신체적 특성, 영양소 섭취상태 및 혈중 지질농도 양상)

  • 양윤정;김진옥
    • Journal of Nutrition and Health
    • /
    • v.33 no.1
    • /
    • pp.59-67
    • /
    • 2000
  • The objective of this study was to investigate nutritional status of middle aged Korean men exhibiting impaired glucose tolerance (IGT) and identify the risk factors related to IGT Data were collected from 163 men with a fasting blood glucose level from 115 to 139mg/dl(high blood glucose group: HBG) and 170 men with a normal fasting blood glucose level(control) aged from 40 to 59 years in both groups. Weight, body mass index(BMI) and percent body fat were significantly higher in high blood glucose(HBG) group than those of control group. Age, weight, BMI, percent body fat were positively related to blood glucose. There were no differences in exercise, smoking and family history of diabetes between two groups. Frequency of fat eating and overeating of HBG were higher than those of control group but frequency of sweet snacks intake of HBG was lower than that of control group. There was no difference in daily total energy intake in two groups. Total and supper energy intakes were positively associated with blood glucose. Percent energy intake of alcohol was significantly higher in HBG group and positively related to blood glucose, however there were no difference in daily intake of nutrients in two groups. Alcohol intake was positively related to BMI, but after adjusting BMI, there was no correlation between alcohol intake and blood glucose. Serum total cholesterol and triglyceride were significantly higher in HBG group than those of control group. Serum total cholesterol i,nd triglyceride were positively related to blood glucose and high density lipoprotein cholesterol was negatively associated with blood glucose. After adjusting BMI, serum triglyceride was positively related to blood glucose. In conclusion, weight, BMI, percent body fat and blood total cholesterol, low density lipoprotein cholesterol and triglyceride levels were positively related to blood glucose level of middle aged Korean men exhibiting impaired glucose tolerance. Their eating habits exhibited higher frequency of overeating, fast eating, high energy intakes of supper. (Korean J Nutrition 33(1) : 59-67, 2000)

  • PDF

Design and Implementation of a Blood-Glucose Meter to Reduce Hematocrit Interference (적혈구 용적률 간섭 보정을 위한 혈당 측정 기기의 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2020
  • A blood-glucose meter is one of the in vitro diagnostic devices to measure and control the glucose concentration of diabetics. In order to measure the glucose level in the blood, the common method is to measure the amount of electrons, that is, the output current generated by glucose oxidation after a blood sample is inserted into the test strip containing an enzyme. The hematocrit is an obstacle in measuring accurate blood glucose concentration. This paper deals with the design and implementation of a blood-glucose meter to correct the hematocrit interference. We propose a sequential method which measures impedance using the alternating current and then measures glucose in the blood using the direct current. In addition, this paper introduces how to use commercial glucose strips based on the proposed system. Finally, we conducted the performance evaluation of the proposed system by comparing the measured current and impedance with those of the references. As a result, the standard deviation of the current measurement is approximately 0.6nA and the impedance measurement error for measuring the hematocrit is approximately within 1%. The proposed system will improve the accuracy of the conventional blood-glucose meter by reducing the hematocrit interference.

Effect of Glucose-Sweetened Drinks on Blood Glucose, Energy, and Water Intake at a Meal 3h Later in Healthy Males

  • Kim, Seok-Young
    • Nutritional Sciences
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2006
  • The aims of this study were to describe the effects of glucose-sweetened drinks on blood glucose, energy, and water intake at a meal 3 hours later. The effect of blood glucose on prandial energy intake and the relationship between water and energy intake during a meal were also determined. Twenty healthy normal-weight men were fed pizza test meals 3h after consuming four drinks of 0, 50g, 65g, and 75g glucose in random order, within-subjects design. Blood samples were measured at baseline and every 30 min after ingestion of drinks and 30min after the end of the test meal and the appetite was also assessed by visual analog test at the same interval. The results of this study showed that various glucose drinks altered blood glucose responses compared with that of water control(p<0.0001). Blood glucose areas under the curve(AUC) for glucose-sweetened drinks were significantly(p<0.05) higher than that for the control over 3 hours after a drink and 30 min after the test meal. Consumption of the glucose-sweetened drinks significantly increased(p<0.05) energy and water intake at a test meal compared with the water control, except the drink containing 75g glucose. For all drinks combined, the energy intake was negatively correlated with the blood glucose and positively correlated with the volume of water consumed at a test meal at 3 hours later.

Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect (헤마토크릿 영향을 최소화한 종이 혈당센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

Patient Outcomes according to Blood Glucose Level in Neonates with Cardiovascular Surgery (심혈관 수술 신생아의 혈당수준에 따른 환아 결과)

  • Hwang, Jeong-Hye;Park, Hyoung-Sook
    • Child Health Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.43-52
    • /
    • 2012
  • Purpose: The purpose of this study was to provide basic data for suitable neonate blood glucose maintenance by investigating and analyzing the blood glucose level of post cardiovascular surgery neonates in the ICU for the effect of blood glucose levels on the following outcomes; ICU stay, hospital stay, mechanical ventilation time, morbidity, and mortality. Methods: The participants were 143 neonates in the ICU after having had cardiovascular surgery. The design for this study was an investigation of the blood glucose levels of the neonates and retrospective analysis of patient outcomes according to blood glucose level. Results: The results for the neonate groups showed that the factors of hospital stay, ICU stay, mechanical ventilation time and mortality, for the group with a blood glucose level over 140 mg/dL were longer and higher than for the group with blood glucose of less than 100 mg/dL or the group between 100-139 mg/dL. Conclusion: The results of this study indicate that when caring for neonates after cardiovascular surgery, it is important to recognize the influence of blood glucose levels on patient outcomes like hospital days, ICU stay, length of time on mechanical ventilation and mortality. Further, care guidelines for neonates' glucose level management need to be developed.

Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

  • Hwang, Joon Ho;Sohn, Yong-Hak;Chang, Seong-Sil;Kim, Seung Yeon
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.301-308
    • /
    • 2015
  • Purpose: We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods: Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ${\leq}2,300g$ or were ${\leq}36$ weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). Results: The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels ${\leq}60mg/dL$, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment, after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ${\leq}60mg/dL$), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Conclusion: Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

Evaluation of Glucose Concentration by Wireless Continuous Glucose Monitoring System in Healthy Dogs (무선 연속 당측정기에 의한 정상 개의 당 농도 평가)

  • Kang, Ji-Houn;Kim, Sung-Soo;Yang, Mhan-Pyo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.392-396
    • /
    • 2010
  • Blood glucose curves in the management for diabetic patients have several limitations including intermittent assessment of blood glucose concentration, hospitalization, patient restraint, and repeated phlebotomy. The aim of this study was to apply and evaluate a wireless continuous glucose monitoring system (CGMS) in healthy dogs. Subcutaneous interstitial glucose concentrations in 7 dogs were continuously monitored and recorded by wireless CGMS. During induced hyperglycemia, the interstitial glucose concentrations were compared with whole blood glucose concentrations measured by glucometer and serum glucose concentrations measured by automated chemistry analyzer, respectively. There were no significant differences among interstitial, whole blood and serum glucose concentrations. The interstitial glucose concentrations had a good correlation to serum glucose concentrations. The real-time wireless CGMS is a valuable tool for monitoring system of glucose concentrations in dogs. Use of the CGMS for diabetic patients will provide accurate information over traditional blood glucose curves.

Effects of Multi-Extracts of Mori Folium and of Exercise on Plasma Insulin and Glucose Levels in Streptozotocin-Induced Diabetic Rats

  • Ko, Young-Cheol;Song, Kyung-Hee
    • Nutritional Sciences
    • /
    • v.6 no.4
    • /
    • pp.201-208
    • /
    • 2003
  • This research was conducted to study the effects of the supplementation of multi-extracts of mori folium (MF) and of exercise on plasma insulin and glucose levels in streptozotocin (STZ)-induced diabetic rats. Eight male Sprague-Dawley rats, 4 weeks old, were assigned to each experimental group and were raised in the laboratory for 10 weeks. The animal groups consisted of a normal-control group, a STZ-control group, 3 STZ-induced diabetic groups supplemented ad libitum with various amounts of MF extracts (MF-720, MF-360, and MF-180 groups), and a STZ-induced diabetic group supplemented with MF-360 along with exercise. In the normal-control group, glucose tolerance tests resulted in the peak blood glucose level being achieved in 15 minutes and a fasting blood glucose level being achieved in 60 minutes. In the STZ-control group, the peak blood glucose level was reached after 60 minutes and, even after 90 minutes, blood glucose shown at a significantly higher level compared to the fasting levels. In the groups supplemented with MF extracts, the blood glucose level peaked after 30 minutes of glucose challenge, and returned to the fasting level after 90 minutes; the MF-360 and MF-360+exercise groups showed the best levels of glucose tolerance. Blood glucose levels in the STZ-induced diabetic groups were significantly higher compared to the normal-control group. However, after 7 weeks of supplementation with MF extracts, a significant lowering of blood glucose levels was observed in all groups supplemented with the MF extract. The best effect was observed in the group given MF extract combined with exercise. Compared to the normal-control group, blood insulin levels were significantly lower in all STZ-induced diabetic groups; however, a significantly higher level of insulin was observed in the groups given MF extracts compared to the STZ-control group. This study shows that the supplementation of MF extracts in STZ-induced diabetic rats resulted in increased blood insulin levels and lower blood glucose levels.

Triglycerides and C-peptide are Increased in Obese Type 2 Diabetic Patients (비만 제2형 당뇨병 환자에서 중성지방과 C-peptide 증가)

  • Kim, Hee-Seung;Song, Min-Sun;Yoo, Yang-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.2
    • /
    • pp.41-49
    • /
    • 2002
  • Aim To evaluate blood pressure, blood glucose and serum lipid level in obese and nonobese type 2 diabetic patients. Methods 206 obese(76 male, 130 female) and 442 nonobese(208 male, 234 female) type 2 diabetic patients underwent fasting blood glucose, 2-hour postprandial blood glucose, $HbA_1c$ total cholesterol, triglyceride, high density lipoprotein, microalbuminuria, blood urea nitrogen, creatinine and C-peptide were measured. Diabetes was diagnosed according to the American Diabetes Association(ADA)criteria. Obesity was defined as body mass index(BMI, kilograms per meters squared)${\geq}25$. Results In male, systolic blood pressure, triglycerides, microalbuminuria and C-peptide were significant higher in obese than nonobese patients. Fasting blood glucose were significantly lower in obese than nonobese patients. Diastolic blood pressure, 2-hour postprandial blood glucose, $HbA_1c$, total cholesterol, high density lipoprotein, blood urea nitrogen, and creatinine were no difference between 2 groups. In female, triglycerides and C-peptide were significant higher in obese than nonobese patients, Blood pressure, fasting blood glucose, 2-hour postprandial blood glucose, $HbA_1c$, total cholesterol, high density lipoprotein, microalbuminuria, blood urea nitrogen, and creatinine were no difference between 2 groups. Conclusion Our present study supports that increased triglycerides play a major role in increasing the risk of coronary heart disease(CHD) in obese women type 2 diabetic patients.

  • PDF