• Title/Summary/Keyword: cement burn

Search Result 10, Processing Time 0.028 seconds

Burn-up Characteristics of Polymer-Modified Cement Mortar Used for Building Repair (고온시에서의 폴리머 시멘트 모르타르의 연소특성에 관한 연구)

  • Kim, Hyung-Jun;Noguchi, Takahumi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.295-298
    • /
    • 2012
  • Repair and strengthening is necessary to extend the service life of existing buildings. Polymer-modified cement mortar (PCM) has been extensively used as a high performance material particularly for finishing and repairing works in concrete building because of itsexcellent adhesion, waterproofing, resistance to chemical attack, and workability. As PCM contains organic polymer, it is necessary to clarify its properties at high temperature under fire, on which sufficient data are not available. This paper evaluated the burn-up characteristics of polymer-modified cement mortar with cone calorimeter test, non-combustibility test and flammability test with experimental parameters such as the types of polymer, unit-polymer content, polymer-cement ratio and thickness of the specimen.

  • PDF

A Study on the Effect of Reclaiming-Fuel in Coement Kiln (시멘트 공장에서의 재생연료 사용효과 연구)

  • 김도겸;이장화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.37-43
    • /
    • 1996
  • The high Temperatures and long residence times in the combustion zones of cement kiln can use to burn liquid and solid wastes, such as fuel-wastes, sludges and tire-wastes. To the lastest time, treatment methods of industrial waste are incineration treatment, ocean dumping and land dumping. These are the main methods, but all of them may cause vatious kinds of secondary pollution, including air pollution and water pollution. From this point of view, to reuse the Reclaiming-Fuel in Cement Kiln is the most outstanding waste treatment plant in the world and dose not cause any pollution at all.

  • PDF

The Effect of Hydration Retarder on Initial Compressive Strength of Sodium Silicate-Cement Grouted Soil (시멘트 수화지연제가 규산나트륨-시멘트 그라우트 초기강도에 미치는 영향에 관한 연구)

  • Chun, Byung-Sik;Yoo, Young-Nam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.453-460
    • /
    • 2005
  • Sodium silicate - the usual portland cement which accomplishes a cement pouring reconsideration main stream and sodium silicate(No.3) after reacting sodium silicate(No.3) with the reaction sodium silicate where oxidation natrium which is included does not react with the cement receiving stiffening water it will burn together on underwater and to become the durability lacks pouring it is recognized. From the hazard which improves an advantage it used the additive which relates in congealing and stiffening of the portland cement and sodium tripolyphosphate(STPP) addition hour initial material age(72 hours at once) which does to be revealed the at high-in-tensity is discovered while accomplishing. The effect of additives on the reactions of sodium silicate solution and cement suspesion was investigated by various physical and chemical tests, such as Si-NMR, XRD, SEM uniaxial compression test. The additives were STPP(sodium tripolyphosphate), EDTA, SUGAR. The compressive strength of sodium silicate(No.3) - cement grout with additives was about $1.5{\sim}10$ times higher than that without additive in early age(72 hours).

  • PDF

A Case Study of Chronic Contact Dermatitis from Cement, Treated with Taeeumin Cheonghyeolgangki-tang (태양인(太陰人) 청혈강기탕(淸血降氣湯) 투여 후 호전된 시멘트 접촉 만성 피부염 환자 치험 1례)

  • Kang, Ki-wan;Kim, Min-ji;Kang, Sei-young
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.1
    • /
    • pp.49-57
    • /
    • 2015
  • Objectives : The purpose of this report is to investigate the effect of Taeeumin Cheonghyeolgangki-tang on chronic contact dermatitis caused by cement. Methods : A 52-year-old male patient was diagnosed with contact dermatitis with the Questionnaire for Sasang Constitutional Classification-II (QSCC-II) as well as the four methods of diagnosis (四診), and treated with Taeeumin Cheonghyeolgangki-tang (qīngxuèjiàngqí-tāng). We observed redness and scaling on both palms, and recorded photographs of any changes during the inpatient and outpatient treatment period. Results : The symptoms of contact dermatitis on both palms were significantly improved. Scaling and cracked skin disappeared and the redness almost resolved. Conclusions : Therefore, Taeeumin Cheonghyeolgangki-tang ( qīngxuèjiàngqí-tāng ) is effective on chronic contact dermatitis caused by cement.

Low & Intermediate Level Radioactive Waste Vitrification Using Plasma Arc Melting Technology

  • Min Byeong-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.482-496
    • /
    • 2003
  • effectiveness of the PAM graphite-electrode technology for the treatment of many types of low-level radioactive waste including : combustible material, solidified resins in cement, inorganic materials, steel, glass, and solidified boric acid cement. The objectives of PAM-200 evaluation were to verify that 1) the facility meets air emission regulations, 2) the facility can be safely operated when processing hazardous and radioactive materials and 3) satisfactory final waste forms can be produced. Results, derived from KAERI's(Korea Atomic Energy Research Institute) analyses for samples of vitrified product, scrubbing solution and offgas collected during test period, show that PAM-200 can treat radioactive wastes as well as hazardous wastes with toxic constituents and radionuclides contained in the offgas exiting from the stack to the environment controlled to be far lower than the limit regulated by air conservation law and atomic law.

Case Study on NOx Emissions from Cement Kiln before and after Applying Multi-stage Combustion Technology (다단연소 기술 적용 전후 시멘트 소성설비의 NOx 배출 사례 연구)

  • Jae-Won, Choi;Ju-Ik Back;Jang-Jung Kim;Phil-Sung Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.267-275
    • /
    • 2023
  • The cement industry has been contributing to solve the wastes problem by using various combustible wastes as alternative fuel to replace natural coal. To use more alternative fuels such as waste plastics, in the cement manufacturing process, it is necessary to stably burn alternative fuels and reduce air emissions such as NOx. This study is a case study on the multi-stage combustion calciner process, which is a technology that decreases the amount of NOx while increasing the use of alternative fuels. This study is a case study on the multi-stage combustion process, a technology that reduces the amount of harmful air emissions such as NOx while increasing the use of alternative fuels. Along results of comparing before and after applying the technology to actual cement manufacturing facilities, the amount of coal consumption decreased by 38 %, waste plastics consumption increased by 122 %, and NOx emissions decreased by 17 %. Results show that increasing the use of alternative fuels and reducing NOx emissions by multi-stage combustion is effective.

Proper Mixing Ratio for Securing Quality of Free-form Panel (비정형 패널의 형상 품질확보를 위한 적정 배합비 도출)

  • Kim, Min-Sik;Park, Chae-Wool;Kim, Ki-Hyuk;Do, Sung-Lok;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.5
    • /
    • pp.449-456
    • /
    • 2019
  • Recent developments in architectural technologies and programs have enabled architects to think creatively and design free-form architecture. however, there are many problems in the production technology of FCP(Free-Form Concrete Panel). In particular, reduced accuracy due to lack of free-form panel production technology can lead to redesign of buildings as a result, problems such as an increase in construction cost and period. Therefore, this experiment aimed to compensate the decrease of the accuracy according to the displacement difference and to derive the proper mixing ratio for maintaining the shape during the free-form panel curing. In this study, molds were made using paraffin that is a recyclable phase change material. Concrete Panel is usually produced from Portland cement, dead burn magnesia, phosphate, borax and fine aggregate. In this study, four mixing ratios of FCP were selected after each material was blended to determine the proper blending ratio of the fluidity phase, the water absorption rate and the water content of the test piece. FCP was fabricated on the basis of the selected four compounding ratios and thickness and error rate were measured. Based on the error rate of the measured FCP, the quality standard was satisfied among the four compounding ratios.

Surgical Treatment of Squamous cell Carcinomas Arising in Scalp Burn Wounds - Two Case Reports - (화상 후 두피에 생긴 편평 상피세포 종양에 대한 증례 보고 - 증례보고 -)

  • Kim, Kang San;Hwang, Hyung Sik;Kwon, Heum Dai;Moon, Seung Myung;Oh, Suk Jun;Choi, Sun Kil
    • Journal of Trauma and Injury
    • /
    • v.20 no.1
    • /
    • pp.52-56
    • /
    • 2007
  • Marjolin's ulcer is a rare and often-aggressive cutaneous malignancy that arises in previously traumatized or chronically inflamed skin, particularly after burns. We experienced two cases after burns. Case I involved a forty eight year-old man who had suffered from a flame burn at the parietal scalp area, where had been initially described three years earlier as a full-thickness wound including the pericranium. The man consulted us for a persistent ulcerative and infected wound on the burned lesion during the last 24 months, which turned out on the contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) to be the squamous cell carcinoma with involving the skull and the dura mater. Although the posterior auricular lymph node was enlarged on the ipsilateral side, recent positron emission tomography (PET) CT did not show any metastatic lesion. It was impossible for us to resect the intracranial involvement of the tumor radically, and the postoperative PET CT still showed a focal fluorodeoxyglucose (FDG) uptake around the wall of the superior sagittal sinus. We think that an aggressive combined approach is essential for treatment in early stages for a high success rate, before the intracranial structures are involved because there is no consensus on the treatment for advanced disease, and the results are generally poor. Case 1 also did not involve a radical resection because of the intracranial invasion to the wall of superior sagittal sinus and the possibility of damage to the major cortical veins. He received adjuvant radiotherapy and must be followed periodically. Case 2 involved an eighty six year-old women who suffered from a painful scalp ulcer lesion after flame burns three years earlier. Unlike case 1, neither tumor infiltration into the dura nor lymph node enlargement was observed on the contrast-enhanced computed tomography (CT), magnetic resonance imaging (MRI), or positron emission tomography (PET) CT. We did a radical resection of the tumor, including the involved bone, and a cranioplasty with bone cement.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.