• Title/Summary/Keyword: chamber width

Search Result 157, Processing Time 0.026 seconds

Performance Evaluation of Rotational Flow of a 2×2 Microfluidic Centrifuge with varying Inlet Conditions and Chamber Sizes (마이크로 유체 원심분리기의 입구 조건과 챔버 크기에 따른 회전 유동 성능 평가)

  • Jeon, Hyeong Jin;Kwon, Bong Hyun;Kim, Dae Il;Kim, Hyung Hoon;Go, Jeung Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • This paper describes the measurement of performance evaluation of rotational flow varying chamber size and Reynolds number. Through the experimental visualization of the flow rotation, the number and position of flow rotation in the $2{\times}2$ microfluidic centrifuge were examined. At a chamber width of 250${\mu}m$, single flow rotation was obtained over at a Reynolds number of 300, while at a chamber width of 500 ${\mu}m$, single flow rotation did not appear. For performance evaluation, the intensity in microchamber was measured during 20 sec. At a chamber width of 250 ${\mu}m$, performance of rotational flow increased as Reynolds number increased. However, the variation of intensity in microchamber remained unchanged at a chamber width of 500 ${\mu}m$. The numerical analysis showed that the threshold centrifugal acceleration to obtain rotational flow for ejected particles was 200g.

CFD-Based Overpressure Evaluation Inside Expansion Chamber-Applied Protective Tunnels Subjected to Detonation of High Explosives (확장챔버를 적용한 방호터널 내부의 CFD 해석 기반 폭발압력 평가)

  • Shin, Jinwon;Pang, Seungki
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.1
    • /
    • pp.25-34
    • /
    • 2023
  • This paper presents a computational fluid dynamics (CFD) analysis to investiagate the effect of expansion chamber on overpressure reduction in protective tunnels subjected to detonation of high explosives. A commercial CFD code, Viper::Blast, was used to model the blast waves in a protective tunnel with a length of 160 m, width of 8.9 m and height of 7.2 m. Blast scenarios and simulation matrix were establihsed in consideration of the design parameters of expansion chamber, including the chamber lengths of 6.1 m to 12.1 m, widths of 10.7 m to 97 m, length to width ratios of 0.0 to 5.0, heights of 8.0 m and 14.9 m, and ratios of chamber to tunnel width of 1.2 to 10.9 m. A charge weight of TNT of 1000 kg was used. The mesh sizes of the numerical model of the protective tunnel were determined based on a mesh convergence study. A parametric study based on the simulation matrix was performed using the proposed CFD tunnel model and the optimized shape of expansion chamber of the considered tunnel was then proposed based on the numerical results. Design recommendations for the use of expansion chamber in protective tunnel under blast loads to reduce the internal overpressures were finally provided.

Visualization of Rotational Flow for Chamber Size of a 2×2 Microfluidic Centrifuge (마이크로 유체 원심분리기의 챔버 크기에 따른 회전 유동 가시화)

  • Jeon, Hyeong Jin;Kwon, Bong Hyun;Kim, Dae Il;Go, Jeung Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.25-29
    • /
    • 2012
  • This paper introduces a new parameter to design the $2{\times}2$ microfluidic centrifuge with single flow rotation positioned at the center of microchamber. The dimensional centrifugal acceleration momentum flux which is defined as the interfacial momentum flux divided by distance from the center of the chamber explains the flow rotation and its threshold provides a reference to expect single flow rotation. Through the numerical and experimental visualization of the flow rotation, the number and position of flow rotation in the $2{\times}2$ microfluidic centrifuge were examined. At a channel width of $50{\mu}m$ and chamber width of $250{\mu}m$, single flow rotation was obtained over at a Reynolds number of 300, while at a channel width of $100{\mu}m$ and chamber width of $500{\mu}m$, single flow rotation did not appear. The numerical analysis showed that the threshold centrifugal acceleration momentum flux to obtain single flow rotation was $3500kg/m{\cdot}s^2$.

Hydraulic Experiments for the Reflection Characteristics of Perforated Breakwaters (유공방파제의 반사특성에 관한 수리실험)

  • 박우선;전인식;이달수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.3
    • /
    • pp.198-203
    • /
    • 1993
  • Hydraulic experiments were carried out to investigate the reflection characteristics of perforated breakwaters in regular wave conditions varying the width of wave chamber and the shape of perforated wall. It was found that the reflection coefficient of the perforated breakwater was very sensitive to the change of wave chamber width. giving its minimal value when the width of the wave chamber is approximately 0.2 times the wave length in the wave chamber. This phenomenon may be resulted from the wave resonance inside the wave chamber. The reflection coefficients slightly varied for all shapes of perforated wall. i.e., vortical slit, horizontal slit or circular hole. However, the reflection trend of the structure was not significantly affected by the shape of the perforated wall.

  • PDF

Manipulation of Microfluid Width in a Microchannel Using Gas Boundary (미세 채널에서 가스 경계면을 이용한 미세 유체의 폭 조절)

  • Son, Sang-Uk;Lee, Seung-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1190-1195
    • /
    • 2004
  • A novel manipulation of microfluid width in a microchannel was presented by controlling inflation of a gas boundary. The gas boundary was formed by heating water with a microheater in a semicircular shape from a chamber which was connected symmetrically to the microchannel. The formed gas boundary inflated perpendicularly to the flow direction and, consequently, the microfluid width was narrowed. The inflation and contraction were flexibly like a virtual wall and dependent on two factors: one is the flow velocity of the microfluid and the other is the pressure inside the gas boundary. Dimensions of the chamber and the microchannel width were determined empirically as same of $300\;{\mu}m$ for stable operation. The width of microfluid was manipulated manually with the microheater and could be maintained as up to $22\;{\mu}m$. The stable focusing began to be distorted when the flow velocity exceeded 17.8 mm/s.

Reflection Characteristics of Vortical Slit Caisson Breakwater (종 SLIT형 케이슨 방파제의 반사특성)

  • 이종인;조지훈
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • Recently, some attempts to construct slit caisson-type breakwaters are made in Korea. Since slit caisson-type breakwaters are suitable for relatively deep sea areas, a lot of theoretical and experimental researches have been performed. In this study, the reflection characteristics of vertical slit caisson breakwaters are investigated based on the measured data in two-dimensional hydraulic model tests with irregular waves. The experiments were conducted for various cases; variation of porosity of perforated-wall, width of wave chamber, number of slits for single-and double-chamber, respectively. It is found that in the case when the wave steepness (H/L$_{s}$ ) is small, the reflection coefficients are large. The existing researches have shown that the wave reflection is minimized when the nondimensional width of wave chamber B/L is about 0.2~0.25 for the regular waves. However, for the irregular waves the reflection is lowest when $B/L_2$, is 0.13~0.15. For a same porosity condition, the wave dissipation is stronger as the width of s1it is larger. The double-chamber caisson is superior to single- chamber caisson in the wave dissipating effects.

  • PDF

Wave Energy Absorption by a Circular Cylinder Oscillating Water Column Device (원통형 진동수주 파력발전장치에 의한 파 에너지 흡수)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.1
    • /
    • pp.8-18
    • /
    • 2002
  • In this paper, wave energy absorption of OWC(oscillating water column) device is analyzed. The analytic model consists of a partially immersed circular vertical cylinder open at its end and an air turbine connected with the air chamber. The boundary value problem is decomposed into scattering problem related to scattering by an incident wave in the absence of a pressure variation and radiation problem describing the flow due to an oscillating pressure in the absence of an incident wave. By invoking the continuity of an air flow inside the chamber, the oscillating pressure in a chamber is derived. With oscillating pressure, the mean power absorbed by OWC device and the capture width are obtained. In numerical calculation, the induced volume flux across the internal free surface of the chamber in the scattering and radiation problem and the maximum capture width are compared with various design parameters such as radius and submergence depth of chamber and wave conditions. The maximum capture width obtained by choosing the optimal value of turbine constant occurs at the first resonant mode (Helmholtz mode) among the natural frequencies of a circular cylinder chamber.

A Study on the Korean Fit Test Panel and Static Headform Chamber (한국형 테스트 패널과 Static Headform Chamber 개발연구)

  • Hyekyung Seo;Hoyeong Jang;Harim An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.145-155
    • /
    • 2023
  • Objectives: A fit test panel is needed to identify the fit performance of a respirator and its face seal. This is a criterion for selecting subjects that can represent the facial characteristics of users. Although anthropometry data has been developed for people in United States and China it is not yet present in Korea. This study aimed to develop a Korean fit test panel and test headform. Methods: For the 7th and 8th waves of the Size Korea anthropometry data, facial measurements of 11,429 people aged 15 to 69 years were used for analysis. PCA and bivariate panel were classified using the ISO16976-2:2022(E) anthropometrics analysis method. Based on this result, a static headform was developemed and a fit test chamber was constructed. Results: Of the 11,429 Korean people used for principal component analysis, 11,300 were included in the ellipse, marking an acceptance rate of 98.87% on PCA panel. The face types were classified into five types. Among them, a large, medium, and small static headform were printed using a 3D printer. In addition, 10,985 people (96.12%) were included in the bivariate panel based on face length and face width. The y-axis (face length) boundary was 97.87 to 134.59 mm, and the x-axis (face width) boundary was 120.75 to 158.23 mm. Conclusions: Compared to the ISO analysis, the Korean principal component was narrower in the width item (PC1) and longer in the length item (PC2). For the future, it is necessary to conduct a fit test using the developed headform and chamber device to confirm the usefulness of this Korean test panel. Therefore, this study is considered valuable as basic research for Korean test panels.

The Fuel Spray Structure of High Pressure Gasoline Injector in a Constant Volume Chamber (정적챔버내의 고압 가솔린 인젝터의 연료분무구조)

  • 귄의용;조남효
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.10-17
    • /
    • 2000
  • This work presents an investigation of aerodynamic characteristics of fuel spray injected from a high pressure hollow cone swirl injector into a constant volume chamber. Laser tomography visualization was used to interrogate the fuel and air mixing characteristics and the effect of chamber pressure and temperature increase was analyzed, Preliminary results on spray development showed that mixing effect tends to increase with the increase of injection pressure and chamber gas pressure yielding a decrease of spray penetration and an attenuation of well-defined vortex structure. Topological analysis of the spray structure has been performed to initiate the understanding of mixing and vaporization process. For the present experimental conditions fuel injection pressure and chamber gas pressure appear as the dominant factors which govern the transient mixing characteristics. Moreover spray atmixation characteristics are improved by increasing chamber gas temperature.

  • PDF

Experiments for Side Wall Effects of a Perforated Structure Under Oblique Incident Waves (경사입사파 조건에서 유공구조물의 격벽효과에 대한 실험)

  • Lee, Jong-In;Kim, Sun Ou;Kim, Kyoung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2343-2350
    • /
    • 2013
  • The wave height distributions in front of a vertically perforated wall structures for obliquely incident uni-directional irregular waves are mainly investigated by using 3D hydraulic experiments. The difference and similarity of wave propagation along the plain and perforated wall structures are investigated and particularly the effects of side walls in chamber and relative chamber width are analyzed. This study shows that the wave height distribution patterns for normalized wave heights in front of structure is significantly different between the plain and perforated wall structures, and the side wall in the chamber suppresses the growth of waves.