• Title/Summary/Keyword: charge center

Search Result 1,163, Processing Time 0.036 seconds

Identification of a novel mutation in the CHD7 gene in a patient with CHARGE syndrome

  • Kim, Yeonkyung;Lee, Ho-Seok;Yu, Jung-Seok;Ahn, Kangmo;Ki, Chang-Seok;Kim, Jihyun
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.1
    • /
    • pp.46-49
    • /
    • 2014
  • CHARGE syndrome has been estimated to occur in 1:10,000 births worldwide and shows various clinical manifestations. It is a genetic disorder characterized by a specific and a recognizable pattern of anomalies. The major clinical features are ocular coloboma, heart malformations, atresia of the choanae, growth retardation, genital hypoplasia, and ear abnormalities. The chromodomain helicase DNA-binding protein 7 (CHD7) gene, located on chromosome 8q12.1, causes CHARGE syndrome. The CHD7 protein is an adenosine triphosphate (ATP)-dependent chromatin remodeling protein. A total of 67% of patients clinically diagnosed with CHARGE syndrome have CHD7 mutations. Five hundred twenty-eight pathogenic and unique CHD7 alterations have been identified so far. We describe a patient with a CHARGE syndrome diagnosis who carried a novel de novo mutation, a c.3896T>C (p. leu1299Pro) missense mutation, in the CHD7 gene. This finding will provide more information for genetic counseling and expand our understanding of the pathogenesis and development of CHARGE syndrome.

Specimen Preparation for Scanning Electron Microscope Using a Converted Sample Stage

  • Kim, Hyelan;Kim, Hyo-Sik;Yu, Seungmin;Bae, Tae-Sung
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.214-217
    • /
    • 2015
  • This study introduces metal coating as an effective sample preparation method to remove charge-up caused by the shadow effect during field emission scanning electron microscope (FE-SEM) analysis of dynamic structured samples. During a FE-SEM analysis, charge-up occurs when the primary electrons (input electrons) that scan the specimens are not equal to the output electrons (secondary electrons, backscattered electrons, auger electrons, etc.) generated from the specimens. To remove charge-up, a metal layer of Pt, Au or Pd is applied on the surface of the sample. However, in some cases, charge-up still occurs due to the shadow effect. This study developed a coating method that effectively removes charge-up. By creating a converted sample stage capable of simultaneous tilt and rotation, the shadow effect was successfully removed, and image data without charge-up were obtained.

Comparison of Nutrient Intake and Meal Service Satisfaction of Elderly at the Local Community Centers : Free and Reduced Meal Service Charge (지역 급식소 성격에 따른 이용 노인의 영양소 섭취수준 및 급식 만족도 비교 : 유료 및 무료 급식)

  • Choi Bong Soon;Kwon Sun Younk;Seo Ju Youne;Lee In Sook;Lee Hee Ja
    • Korean Journal of Community Nutrition
    • /
    • v.10 no.3
    • /
    • pp.303-310
    • /
    • 2005
  • The purpose of this study was to compare the nutrient intake and foodservice satisfaction of homebound elderly had lunch at the local community centers by the difference of meal service charge. Two local community center with cons-regate meal service program located in Daegu and Gyongsan were selected; one with free of meal service charge (F), and the other with 500-1,000 won for meal service charge (K), According to the dietary assessment, energy and nutrient intakes of the 156 elderly subjects were as a whole under the Korean Recommended Dietary Allowance (RDA). Elderly or F service conte. showed higher $\%$ RDA for the selected nutrients and MAR (mean adequacy ratio) than those of K service center (p<0.001). Participants were satisfied with most of the congregation meal service from community conte. with different reasons such as 'tasty (K service center)' and 'free of charge (F service center)'. In conclusion, elderly had the lunch at the community center with free of meal service charge was poor nutrition status and lower socioeconomic level than the other type of community center in this area. Therefore, healthy menu for elderly should be developed and managed by professional dietitian, as well as its impact on health status of this group, and congregate meal service system might be extended to the homebound elderly of whole community with free of charge.

Characterization of the Vertical Position of the Trapped Charge in Charge-trap Flash Memory

  • Kim, Seunghyun;Kwon, Dae Woong;Lee, Sang-Ho;Park, Sang-Ku;Kim, Youngmin;Kim, Hyungmin;Kim, Young Goan;Cho, Seongjae;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.167-173
    • /
    • 2017
  • In this paper, the characterization of the vertical position of trapped charges in the charge-trap flash (CTF) memory is performed in the novel CTF memory cell with gate-all-around structure using technology computer-aided design (TCAD) simulation. In the CTF memories, injected charges are not stored in the conductive poly-crystalline silicon layer in the trapping layer such as silicon nitride. Thus, a reliable technique for exactly locating the trapped charges is required for making up an accurate macro-models for CTF memory cells. When a programming operation is performed initially, the injected charges are trapped near the interface between tunneling oxide and trapping nitride layers. However, as the program voltage gets higher and a larger threshold voltage shift is resulted, additional charges are trapped near the blocking oxide interface. Intrinsic properties of nitride including trap density and effective capture cross-sectional area substantially affect the position of charge centroid. By exactly locating the charge centroid from the charge distribution in programmed cells under various operation conditions, the relation between charge centroid and program operation condition is closely investigated.

Aft-Igniter Performance related to the Formulation and the Shape of Ignition Charge (점화제 조성과 형상에 따른 후방 점화기 성능)

  • Jung, Jin-Suk;Ahn, Gil-Hwan;Jang, Seung-Gyo;Ryu, Byung-Tae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.387-393
    • /
    • 2014
  • The combustion pressure and thrust of aft-igniter were measured to investigate the characteristics of ignition charge. Granule and pellet shape ignition charge of $BKNO_3$ and MTV(Magnesium-Teflon-Viton) were used for igniters. Ignitions with granule charges show abrupt increases of combustion pressure and thrust compared to those of pellet charge. $BKNO_3$ igniter shows higher combustion pressure than MTV igniter due to higher combstion rate. Mg particle size affects the combustion pressure of MTV igniter.

Transport of space charge between sub-pixels in AC-plasma cell discharge

  • Lee, S.B.;Park, E.Y.;Han, Y.G.;Moon, M.W.;Oh, P.Y.;Song, K.B.;Lee, H.J.;Son, C.G.;Jeong, S.H.;Yoo, N.L.;Hong, Y.J.;Jeong, S.J.;Kim, J.H.;Park, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.929-931
    • /
    • 2006
  • In this experiment, we have investigated that the transported space charge between sub-pixels in AC-plasma cell discharge. The test pulse 30 V, $5{\mu}s$ was applied to the address electrodes of neighbor cells of discharge occurred cells. And we have measured the transported space charge between sub-pixels in accordance with the various last sustain pulse widths t(time gap between the rising edges of sustain and test pulses) of 0.2 to $3{\mu}s$. It was observed that the peak value of transported space charge has been shown to be 21.5pC at $1.0{\mu}s$. And the IR peak value have been occured after $0.51{\mu}s$ with respect to sustain voltage.

  • PDF

The Surface Modification of Electrode with Solid Electrolyte Interphase for Hybrid Supercapacitor

  • Choi, Min-Geun;Kang, Soo-Bin;Yoon, Jung Rag;Lee, Byung Gwan;Jeong, Dae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1102-1106
    • /
    • 2015
  • A hybrid supercapacitor (HS) is an energy storage device used to enhance the low weight energy density (Wh/kg) of a supercapacitor. On the other hand, a sudden decrease in capacity has been pointed out as a reliability problem after many charge/discharge cycles. The reliability problem of a HS affects the early aging process. In this study, the capacity performance of a HS was observed after charge/discharge. For detailed analysis of the initial charge/discharge cycles, the charge and discharge curve was measured at a low current density. In addition, a solid electrolyte interphase (SEI) layer was confirmed after the charge/discharge. A HC composed of a lithium titanate (LTO) anode and active carbon cathode was used. The charge/discharge efficiency of the first cycle was lower than the late cycles and the charge/discharge rate was also lower. This behavior was induced by SEI layer formation, which consumed Li ions in the LTO lattice. The formation of a SEI layer after the charge/discharge cycles was confirmed using a range of analysis techniques.

Coordinated State-of-Charge Control Strategy for Microgrid during Islanded Operation

  • Kim, Jong-Yul;Jeon, Jin-Hong;Kim, Seul-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.824-833
    • /
    • 2012
  • In this paper, a coordinated state-of-charge (SOC) control strategy for the energy storage system (ESS) operating under microgrid islanded mode to stabilize the frequency and voltage was proposed. The proposed SOC control loop is made up of PI controller, which uses a SOC state of the energy storage system as an input and an auxiliary reference value of secondary control as an output. The SOC controller changes the auxiliary reference value of secondary control to charge or discharge the ESS. To verify the proposed control strategy, PSCAD/EMTDC simulation study was performed. The simulation results show that the SOC of the ESS can be regulated at the desired operating range without degrading the stabilizing control performance by proposed coordinated SOC control method.

Influence of wall charge configurations prior to addressing discharge on dynamic margin in AC Plasma Display Panel

  • Jung, Y.;Choi, J.H.;Jung, K.B.;Kim, S.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.764-767
    • /
    • 2003
  • We have experimentally investigated the influence of wall charge configurations prior to addressing discharge on dynamic margin in AC plasma display panel. In this experiment, we have analyzed the quantity and polarity of wall charge accumulated on the front and rear dielectrics just prior to the addressing discharge under the conventional driving sequence.

  • PDF

Dual charge pump inverter For LCD Backlight Drive Application (대화면 LCD backlight 구동을 위한 Dual charge pump inverter)

  • Jang, Doo-Hee;Kwon, Gi-Hyun;Roh, Chung-Wook;Han, Sang-Kyoo;Hong, Sang-Kyoo;SaKong, Sug-Chin;Lee, Hyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.375-377
    • /
    • 2007
  • 본 논문에서는 LCD backlight 구동을 위한 Dual charge pump inverter를 제안하였다. 제안 회로는 넓은 입력 및 부하 범위에서 영전압 스위칭(Zero Voltage Switching) 동작을 보장하여 효율이 높은 장점을 가진다. 기존 full bridge 방식의 회로와 비교하여 동등한 수준의 소자 전압 스트레스를 가지며, 트랜스포머 1차측 양단 전압을 Full_Bridge 방식에 비해 2배로 만들 수 있어 트랜스포머의 턴비 감소 효과를 얻을 수 있다. 또한 각 소자 전류 스트레스를 기존 대비 1/2로 줄일 수 있는 장점을 가진다. 위와 같이 제안한 회로의 타당성 검증을 위해 시뮬레이션과 40인치 LCD Pannel에 적용하여 실험을 수행하였다.

  • PDF