• Title/Summary/Keyword: classification of the causes of fire

Search Result 26, Processing Time 0.025 seconds

A New Approach to Statistical Analysis of Electrical Fire and Classification of Electrical Fire Causes

  • Kim, Doo-Hyun;Lee, Jong-Ho;Kim, Sung-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • This paper aims at the statistical analysis of electrical fire and classification of electrical fire causes to collect electrical fires data efficiently. Electrical fire statistics are produced to monitor the number and characteristics of fires attended by fire fighters, including the causes and effects of fire so that action can be taken to reduce the human and financial cost of fire. Electrical fires make up the majority of fires in Korea(including nearly 30% of total fires according to recent figures), The incorrect and biased knowledge for electrical fires changed the classification of certain types of fires, from non-electrical to electrical. It is convenient and required to develop the standardized form that makes, in the assessment of the cause of electrical fires, the fire fighters directly ticking the appropriate box on the fire report form or making an assessment of a text description. Therefore, it is highly recommended to develop electrical fire cause classification and electrical fire assessment on the fire statistics in order to categorize and assess electrical fires exactly. In this paper newly developed electrical fire cause classification structure, which is well-defined hierarchical structure so that there are not any relationship or overlap between cause categories, is suggested. Also fire statistics systems of foreign countries are introduced and compared.

Development of a Classification System for an Electrical Fire Investigation (전기화재 조사를 위한 분류체계 개발)

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

Classification of Hazard Events and Causes for Railway Fire Accident (열차 화재안전성 향상을 위한 위험사건 정의 및 원인분류 연구)

  • Kwak, Sang-Log;Wang, Jong-Bae;Park, Chan-Woo;Park, Joo-Nam
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1163-1167
    • /
    • 2007
  • Many railway safety measures are carried out after Daegue subway fire accident. Such as replacement of train interior material, fire extinguish and toxic gas evacuation facilities, exercise on emergency response, setting up of national safety management system, and safety technology research. But these safety measures are not considered by system safety due to lack of risk and hazard information. In order to assess fire risk on system level, we proposed hazard events and causes classification for railway fire accident risk analysis.

  • PDF

Development of Cause Classification Method for Improving Reliability of Electrical Fire Statistics (전기화재 조사 및 통계의 신뢰성 향상을 위한 원인분류방법의 개발)

  • Jeon, Jeong-Chay;Jeon, Hyun-Jae;Lee, Sang-Ick;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.466-471
    • /
    • 2007
  • Electrical fires form over 30 percent of fires, but the study on the reliability of electrical fire statistics is not performed. Electrical roe occupancy was very high due to investigating and classifying fires, which is not directly continuous with electrical cause, as electrical fire because insufficiency of cause classification method or system, and the problems of the reliability of electrical fire statistics were presented. So, the reliability of electrical fire statistics must be guaranteed by improvement of the existing cause classification method of electrical fire. This paper analyzed the problems of electrical rue statistics by the existing cause classification method of electrical fire and presented the new method to classify causes of electrical fire.

  • PDF

Gas Fire Accident Cause Survey Study (가스화재사고 원인조사 연구(LP가스를 중심으로))

  • Kim, Young-Cheol;Cha, Jong-Ho
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this paper is to report gas fire accident based on classification of the major gas fire causes (including handling mistakes, inferior goods, etc.), fire classifications (fire, explosion, leakages, etc.), damage levels(1st, 2nd, 3rd, 4th grade levels), casualties (death, serious wound, slight injury) since gas fire has been generated according to growth of gaseous fuel consumption on home and enterprises with various accident causes. Among gaseous fuels, LPG facility can be c1assified as gas container, pressure regulator, gas hose, interim valve, combustion port. Any fire or any explosion can be caused from handling mistakes, inferior goods on each parts as stated above. Exact gas fire causes shall be identified based on previous case studies on similar fires with consideration of lesson learns.

  • PDF

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.

A Study on the Analysis and Classification of Types and Causes of Railway Accidents (철도사고 위험분류 및 원인분석에 관한 연구)

  • Park Chan-Woo;Park Joo-Nam;Wang Jong-Bae;Cho Yun-ok
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.599-604
    • /
    • 2005
  • As a public transportation possible to convey a large quantity, the railway is safe and keeps time, but it has hazards to cause a disaster if the accidents such as collision, derailment, and fire occur. So advanced countries carry out System Safety Plan with various program activities which have connected orders to maintain or improve safety level by finding hazards, evaluation, taking measures and practice, and improving problems. Especially they systematically manage hazards to cause railway accidents and the factors which possibly threat safety, using national classification of risk and causes with analysis of the related data such as establishing accident/incident data and safety regulations/standards. As executing railway safety regulations, domestic railway is currently trying to improve railway safety management system. The research of classification system of accidents/incidents is one thing to make railway safety management systems better. In this research, we reviewed hazardous factors of railway systems and classification of the causes as the beginning of system safety management, and we conducted study on development of railway accident classification based on findings of this research. The results are able to be used in identifying hazards and activities of systemic safety management at the step of railway accident report and investigation.

  • PDF

Analysis for Forest Fire Damage Severity Map in Cheongyang

  • Jung Tae-Woong;Yoon Bo-Yeol;Yoo Jae-Wook;Kim Choen
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.537-540
    • /
    • 2004
  • Space-borne multi-sensor data could provide fire scar and bum severity mapping. This paper will present detail mapping of burnt areas in Cheongyange Yesan of Korea with ETM+ image. Burn severity map based on ETM+ image was found to be affected by strong topographic illumination effects in mountainous forest area. Topographic effect is a factor which causes errors in classification of high spatial resolution image like IKONOS image. Minnaert constants J( in each band of ETM+ image is derived for reduction of mountainous terrain effects. Finally, this paper computes quantitative analysis of forest fire damage by each forest types.

  • PDF

Performance Analysis and Improvement of National Fire Safety Code elements of Sprinkler System (스프링클러설비의 화재안전기준 요소의 성능분석 및 개선방안)

  • Oh, Taekhum;Lee, Jungil
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.413-422
    • /
    • 2013
  • This study evaluated the fire safety code elements through analyze the loss of life when the fire occurred in the facility sprinklers installed evaluated. And through comparison with national fire safety code elements and standards of NFPA 13 in the United States, Was looking for ways to improve for Life and property damage. In the United States, in some cases, if you do not install the sprinkler are installed as per the fire death rate compared to 83 % lower. By contrast, If the domestic rate of 280 % fatalities were 3.37 times than the United States. This lack of fire performance were analyzed uniform occupancy classification, the amount of source of water supply, live not consider the density according to the standard number and the horizontal distance that causes the installation of sprinkler facilities were analyzed.

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF