• Title/Summary/Keyword: colloid

Search Result 428, Processing Time 0.033 seconds

A Study of Liver Scan using $^{113m}In$ Colloid ($^{113m}In$ 교질(膠質)에 의(依)한 간주사(肝走査)에 관(關)한 연구(硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Hong, Chang-Gi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.83-99
    • /
    • 1969
  • There have been reported numberous cases of liver scanning in use of $^{198}Au$ colloid by many investigators, however, one in use of $^{113m}In$ colloid has not been reported as yet in this country. The dose of $^{113m}In$ for high diagnostic value in examination of each organ was determined and the dignostic interpretability of liver scanning with the use of $^{113m}In$ was carefully evaluated in comparison with the results of the liver scanning by the conventionally applied radioisotopes. The comparative study of both figures of liver scannings with the use of $^{113m}In$ colloid and $^{198}Au$ colloid delivered following results: 1. The liver uptake rate and clearance into peripheral blood were accentuated more in case of $^{113m}In$ colloid than in case of $^{198}Au$ colloid. 2. The interpretability of space occupying lesion in liver scanning with $^{113m}In$ was also superior to one with $^{198}Au$. 3. The figure of liver scanning with $^{113m}In$ colloid corresponds not always to the figure with $^{198}Au$. This difference can be explained by differences of phagocytic ability of reticuloendotherial system within liver. 4. In the liver scanning with $^{113m}In$ colloid, the spleen is also visualized even in normal examinee. 5. In the cases of disturbed liver function, uptake is more decreased in use of $^{113m}In$ colloid than in $^{198}Au$, in the spleen, however, the way is contrary. 6. With use of $^{113m}In$ colloid, the time required for scanning could be shortened in comparison with $^{198}Au$. 7. The filtration of $^{113m}In$ colloid for scanning prior to human administration gives an expectation for better scanning figure.

  • PDF

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Synthesis of Nanosized Titanium-Colloid by Sol-Gel Method and Characterization of Zinc Phosphating (졸-겔법에 의한 나노크기의 티탄-콜로이드 합성 및 인산염 피막 특성)

  • Lee Man Sig;Lee Sun-Do
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2005
  • Nanosized titanium-colloid particles were prepared by sol-gel method. The physical properties, such as thermal stability, crystallite size and crystallinity according to synthesis condition have been investigated by TEM, XRD, SEM, TGA and DTA. In addition, Zinc phosphating has been studied in order to compare the phosphating characterization of prepared nanosized titanium-colloid particles. The major phase of all the prepared titanium-colloid particles was an amorphous structure regardless of synthesis temperature and the structure was composed of phoshate complex and titanium. The micrographs of HR- TEM showed that nanosized titanium-colloid particles possessed a spherical morphology with a narrow size distribution. The crystallite size of the titanium-colloid particles synthesized at 80℃ was 4-5 nm and increased to 8-10 nm with an increase of synthesis temperature (150℃). In addition, the coating weight increased with an increase of temperature of phosphating solution and when the concentration of titanium-colloid was 2.0 g/l, the coating weight was 1.0 g/㎡.

Radiocolloid Uptake in the Pancreas Islet Cell Tumor: Case Report ($^{99m}Tc$-colloid 섭취를 보인 췌장의 도세포종 : 증례보고)

  • Yang, W.J.;Chung, S.K.;Yeon, S.K.;Shinn, K.S.;Bahk, Y.W.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.145-147
    • /
    • 1994
  • Colloid uptake in various hepatic conditions such as focal nodular hyperplasia, regenerating nodules in the cirrhotic liver, hamartoma, hemangioma and rarely hepatoma has been documented. Extrahepatic tumors may show colloid uptake and they include splenic hemangioma, malignant fibrous histiocytoma, breast carcinoma and Kaposi's sarcoma. The mechanism of colloid uptake in those lesions is associated with phagocytic activity in or around the tumors. We report a pancreas islet cell tumor that showed colloid uptake on $^{99m}Tc$-phytate liver scan without histologic evidence of phagocytosis by tumor cells or infiltration of phagocytes in the tumor Microscopically the tumor was highly vascular and showed diffuse hemorrhage throughtout the tumor. We postulated that extravasation of the colloid into the tumor insterstitium caused nonspecific colloid uptake in this tumor. It is expected that hemorrhagic tumor may show nonspecific colloid uptake without phagocytosis in or about the lesion.

  • PDF

International Joint Research for the Colloid Formation and Migration in Grimsel Test Site: Current Status and Perspectives

  • Sang-Ho Lee;Jin-Seok Kim;Bong-Ju Kim;Jae-Kwang Lee;Seung Yeop Lee;Jang-Soon Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.455-468
    • /
    • 2022
  • Colloid Formation and Migration (CFM) project is being carried out within the Grimsel Test Site (GTS) Phase Ⅵ. Since 2008, the Korea Atomic Energy Research Institute (KAERI) has joined CFM to investigate the behavior of colloid-facilitated radionuclide transport in a generic Underground Research Laboratory (URL). The CFM project includes a long-term in-situ test (LIT) and an in-rock bentonite erosion test (i-BET) to assess the in-situ colloid-facilitated radionuclide transport through the bentonite erosion in the natural flow field. In the LIT experiment, radionuclide-containing compacted bentonite was equipped with a triple-packer system and then positioned at the borehole in the shear zone. It was observed that colloid transport was limited owing to the low swelling pressure and low hydraulic conductivity. Therefore, a postmortem analysis is being conducted to estimate the partial migration and diffusion of radionuclides. The i-BET experiment, that focuses more on bentonite erosion, was newly designed to assess colloid formation in another flow field. The i-BET experiment started with the placement of compacted bentonite rings in the double-packer system, and the hydraulic parameters and bentonite erosion have been monitored since December 2018.

Studies on the Preparation of $^{99m}TC$ Labelled Antimony Sulfide Colloid and Hydroxyethyl Starch for Lymphoscintigraphy (림포신티그래피용 $^{99m}TC$를 표지황화안티몬 콜로이드 및 전분의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok;Lim, Sang-Moo;Hong, Seong-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.

  • PDF

Radionuclide Transport Mediated by Pseudo-Colloid in the fractured Rock Media : Model Development

  • Baik, Min-Hoon;Hahn, Phil-Soo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.769-774
    • /
    • 1995
  • In this study, a transport model was developed in order to analyze and predict the transport behaviors of radionuclides mediated by pseudo-colloid in the fractured rock media. It was resulted that the transport of Pu-239 was faster than Ni-63 because pseudo-colloid formation constant of Pu-239 was greater than that of Ni-63. Also, the effect of pseudo-colloid formation on the transport of a radionuclide was shown to be very significant when the apparent pseudo colloid formation constant, $K_{ap}(m^{3}/kg)$, was greater than 100. Thus, it can be concluded that acceleration of radionuclide migration may be occurred because the pseudo-colloid formation of radionuclides increases the amount of mobile components in the solution and consequently decreases the amount of radionuclides adsorbed on the stationary solid medium.

  • PDF

Evaluation of Cu nano-colloid prepared by electrical wire explosion in liquid phase (액중 전기선폭발법으로 제조된 구리 나노콜로이드의 특성 평가)

  • Yoon, Jae-Cheol;Yang, Sang Sun;Yu, Ji-Hun
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.37-46
    • /
    • 2010
  • Cu nano-colloid was prepared by wire electric explosion process under de-mineralized water and anhydrous ethanol. To control the properties of Cu nano-colloid, experimental conditions such as diameter of Cu wire and applied voltage were changed. The optimal Cu nano-colloid was prepared when the 0.1mm diameter of Cu wire with the applied voltage of 2000 V was used. The shape of Cu particles in colloid was spherical and the XRD result revealed that the phase of Cu particles was cubic phase. About 20nm Cu nanoparticles with high crystallinity were successfully prepared using wire explosion process under anhydrous ethanol and they showed more than 100 hours dispersion stability.

Camparison of the Efficiency for Tc-99m Tin-colloid and Tc-99m Phytate in Sentinel Node Detection in Breast Cancer Patients (유방암 환자의 전초림프절 검사에서 Tc-99m Tin-colloid와 Tc-99m Phytate의 효용성에 대한 비교)

  • Seok, Ju-Won;Kim, In-Ju
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.451-455
    • /
    • 2008
  • Purpose: Lymphoscintigraphy and sentinel node biopsy has become a standard method for detection of axillary lymph node metastasis in breast cancer patients, but the standard radiopharmaceutical was not prepared. About detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy in breast cancer patient, we compared the results of Tc-99m Tin-colloid and Tc-99m Phytate by subareolar injection. Materials and Methods: This study included 382 breast cancer patients who were performed operation during 2001-2008. Three hundred forty nine patients was injected 0.8ml of Tc-99m Tin-colloid (37-185 MBq) by subareolar injection. Thirty three patients was injected 0.8ml of Tc-99m Phytate (37-185 MBq). Lymphoscintigraphy was performed in supine position and sentinel node localization was performed by hand-held gamma probe in operation. Result: Among 349 patients by Tc-99m Tin-colloid, 312 cases (89.4%) localized the sentinel node by lymphoscintigraphy, 304 cases (87.1%) localized by gamma probe. Among 33 patients by Tc-99m Phytate, 32 cases (97.0%) localized by lymphoscintigraphy, 33 cases (100%) localized by gamma probe. Detection rate by lymphoscintigraphy and gamma probe was superior for Tc-99m Phytate compared to that with Tc-99m Tin-colloid, with a statistically significant difference. (p<0.05, p<0.05) Conclusion: Tc-99m Phytate is a better choice for localization of sentinel node than Tc-99m Tin-colloid in breast cancer patients.