• 제목/요약/키워드: column-slab joint

검색결과 56건 처리시간 0.033초

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

플랫 플레이트 구조의 기둥.슬래브 접합부 연성에 관한 연구 (Ductility of Column-Slab eoint in R/C Flat Plate System)

  • 김형기;박복만
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.113-119
    • /
    • 2000
  • The R/C flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problems in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab joint. Recently, the flat plate system accompanied with shear walls to resist the lateral loads is applied to high-rise buidings. Although the flat plate system is not considered in design as part of the lateral load-resisting system, it is required that this system keeps the ductile behavior for the lateral displacement of the building. However, it is unclear whether the column-slab joint possesses ductility enough to survive the lateral deformation. The objective of this paper is to investigate the major parameters that influence the ductility of R/C flat plate system by examining the existing experiments on column-slab joint. The effects of gravity load and shear reinforcement on the ductility of the flat plate system are presented.

보-기둥 접합부의 전단거동에 대한 슬래브 및 횡구속 영향 (Transverse Concinement and Slab Effect on Shear Behavior of Beam-Column Connection)

  • 장극관;서대원;방세용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.419-422
    • /
    • 1999
  • This study was intended to investigate the cyclic behavior of high strength concrete beam-column connection. Four assemblies were designed 2/3 scale beam-column-slab joint and tested. The obtained results are follows. 1) The transverse beams increase the shear resistance and ductility of joint, 2) The slab was contributed to increase of the flexural capacity of the beam, but was not contributed to increase the joint ductility under lateral loads.

  • PDF

Benefits of Puddling of Fiber Reinforced UHSC for Enhanced Transmission of Column Loads

  • Lee, Joo-Ha;Kim, Gyu-Dong;Yoon, Young-Soo
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.75-78
    • /
    • 2005
  • This study reports on the structural characteristics of slab-column connections using an ultra-high-strength-fiber-reinforced concrete. Compression tests were performed on two slab-column and four isolated column specimens. During the column load tests were performing on the slab-column specimens, the slab loads were also applied to consider actual confinement condition at the slab-column joint. The main parameter investigated was the ' puddling ' of ultra-high-strength-fiber-reinforced concrete. This paper also investigates the effects of some parameters on slab-column specimens and isolated column specimens without the surrounding slab for their ability to transmit axial loads from the ultra-high-strength concrete columns through slab-column connections. The beneficial effects of the ultra-high-strength-fiber-reinforced concrete puddling on the transmission of column loads through slab-column connections are demonstrated.

  • PDF

강섬유 보강 초고강도 콘크리트의 확대 타설을 통한 기둥 하중 전달 성능 향상 (Improved Transmission of UHSC Column Loads by Puddling of Fiber Reinforced UHSC)

  • 이주하;양준모;이승훈;윤영수
    • 콘크리트학회논문집
    • /
    • 제19권2호
    • /
    • pp.209-216
    • /
    • 2007
  • 본 연구는 강섬유 보강 초고강도 콘크리트가 적용된 슬래브-기둥 접합부의 구조적 특성을 파악하였다. 2개의 슬래브-기둥 시험체와 4개의 독립 기둥 시험체의 기둥 하중 전달 실험이 수행되었다. 기둥 하중 실험 수행시, 슬래브-기둥 접합부의 실제 구속 상태를 고려하기 위해 슬래브 하중을 적용하였다. 주 변수로는 강섬유 보강 초고강도 콘크리트의 확대 타설이며, 이에 더하여 슬래브의 접합부 구속 효과, 강섬유 보강, 그리고 접합부의 콘크리트 강도 등이 실험을 통해 파악되었다. 또한, ACI Code(2005)와 CSA Standard(2004)의 예측식과 실험 결과를 비교하였다. 슬래브-기둥 접합부를 통한 기둥 하중 전달에 대한 강섬유 보강 초고강도 콘크리트의 효과를 실험을 통해 확인하였다.

Seismic behavior of reinforced concrete column-steel beam joints with and without reinforced concrete slab

  • Tong Li;Jinjie Men;Huan Li;Liquan Xiong
    • Structural Engineering and Mechanics
    • /
    • 제86권3호
    • /
    • pp.417-430
    • /
    • 2023
  • As the key part in the reinforced concrete column-steel beam (RCS) frame, the beam-column joints are usually subjected the axial force, shear force and bending moment under seismic actions. With the aim to study the seismic behavior of RCS joints with and without RC slab, the quasi-static cyclic tests results, including hysteretic curves, slab crack development, failure mode, strain distributions, etc. were discussed in detail. It is shown that the composite action between steel beam and RC slab can significantly enhance the initial stiffness and loading capacity, but lead to a changing of the failure mode from beam flexural failure to the joint shear failure. Based on the analysis of shear failure mechanism, the calculation formula accounting for the influence of RC slab was proposed to estimate shear strength of RCS joint. In addition, the finite element model (FEM) was developed by ABAQUS and a series of parametric analysis model with RC slab was conducted to investigate the influence of the face plates thickness, slab reinforcement diameter, beam web strength and inner concrete strength on the shear strength of joints. Finally, the proposed formula in this paper is verified by the experiment and FEM parametric analysis results.

고강도 콘크리트 보-기둥-슬래브 접합부의 반복하중 실험 (Experimental Study of High Strength Concrete Beam-Column-Slab Connections subjected to cyclic loading)

  • 오영훈;오정근;장극관;김윤일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.339-344
    • /
    • 1995
  • In the design of ductile moment-resisting frames (DMRFs) following the strong column-weak beam dsign philosophy, it is desirable that the joint and column remain essentially elastic in order to insure proper energy dissipation and lateral stability of the structure. The joint has been identified as the "weak link" in DMRFs because any stiffness or strength deterioration in this region can lead to substantial drifts and the possibility of collapse due to P-delta effects. Moreover, the engineer is faced with the difficult task of detailing an element whose size is determined by the framing members, but which must resist a set of loads very different from those used in the design of the beams and columns. Four 2/3-scale beam-column-slab joint assemblies were designed according to existing code requirements of ACI 318-89, representing interior joints of DMRFs with reinforced high strength concrete. The influence on aseismic behavior of beam-column joints due to monolithic slab, has been investigated.estigated.

  • PDF

절곡형 전단보강근을 사용한 슬래브-기둥 접합부의 이력 거동 (Hysteretic Behavior of Slab-Column Joint Using Bended Type Shear Reinforcement)

  • 이현호;이도범;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.211-218
    • /
    • 2006
  • 본 연구에서는 거주형 무량판 구조의 뚫림 전단을 방지하기 위한 연속 절곡된 전단 보강근을 개발하였다. 이를 적용한 슬래브-기둥 접합부에 있어 개발 전단 보강근의 뚫림 전단 성능을 평가하기 위하여, 구조 성능 실험을 수행하였다. 실험 변수는 전단보강근이 없는 경우, 개발 전단보강근을 사용한 경우, 헤드 스터드를 사용한 경우이다. 수평하중에 대한 저항성능을 평가하기 위하여 일정축력하에서의 이력 하중 실험을 수행하였다. 실험결과는 전체 변위 및 접합부 강도 등으로 평가되었다. 이러한 결과로부터, 개발된 전단보강근이 층간변위비 거동에 있어 우수한 성능을 보유함을 확인할 수 있었다.

Cyclic behaviour of concrete encased steel (CES) column-steel beam joints with concrete slabs

  • Chu, Liusheng;Li, Danda;Ma, Xing;Zhao, Jun
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.735-748
    • /
    • 2018
  • In this paper, the cyclic behavior of steel beam-concrete encased steel (CES) column joints was investigated experimentally and numerically. Three frame middle joint samples with varying concrete slab widths were constructed. Anti-symmetrical low-frequency cyclic load was applied at two beam ends to simulate the earthquake action. The failure modes, hysteretic behavior, ultimate load, stiffness degradation, load carrying capacity degradation, displacement ductility and strain response were investigated in details. The three composite joints exhibited excellent seismic performance in experimental tests, showing high load-carrying capacity, good ductility and superior energy dissipation ability. All three joint samples reached their ultimate loads due to shear failure. Numerical results from ABAQUS modelling agreed well with the test results. Finally, the effect of the concrete slab on ultimate load was analyzed through a parametric study on concrete strength, slab thickness, as well as slab width. Numerical simulation showed that slab width and thickness played an important role in the load-carrying capacity of such joints. As a comparison, the influence of concrete grade was not significant.

Seismic behavior and strength of L-shaped steel reinforced concrete column-concrete beam planar and spatial joints

  • Chen, Zongping;Xu, Deyi;Xu, Jinjun;Wang, Ni
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.337-352
    • /
    • 2021
  • The study presented experimental and numerical investigation on the seismic performance of steel reinforced concrete (SRC) L-shaped column- reinforced concrete (RC) beam joints. Various parameters described as steel configuration form, axial compressive ratio, loading angle, and the existence of slab were examined through 4 planar joints and 7 spatial joints. The characteristics of the load-displacement response included the bearing capacity, ductility, story drift ratio, energy-dissipating capacity, and stiffness degradation were analyzed. The results showed that shear failure and flexural failure in the beam tip were observed for planar joints and spatial joint, respectively. And RC joint with slab failed with the plastic hinge in the slab and bottom of the beam. The results indicated that hysteretic curves of spatial joints with solid-web steel were plumper than those with hollow-web specimens. The capacity of planar joints was higher than that of space joints, while the opposite was true for energy-dissipation capacity and ductility. The high compression ratio contributed to the increase in capacity and initial stiffness of the joint. The elastic and elastic-plastic story deformation capacity of L-shaped column frame joints satisfied the code requirement. A design formula of joint shear resistance based on the superposition theory and equilibrium plasticity truss model was proposed for engineering application.