• Title/Summary/Keyword: composite membrane

Search Result 757, Processing Time 0.032 seconds

Enhanced Sensitivity of PEDOT Microtubule Electrode to Hydrogen Peroxide by Treatment with Gold (금 처리를 통한 PEDOT 마이크로튜브 전극의 과산화수소 검출 특성 향상)

  • Park, Jongseo;Son, Yongkeun
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.809-814
    • /
    • 2014
  • An array structure of conducting polymer microtubule was fabricated for an amperometric biosensor. 3,4-Ethylenedioxythiophene (EDOT) was electropolymerized in the microporous template membrane with poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid) (PEDOT/PSS) composite as a binder. The array structure can provide enhanced current collecting capability due to large active surface area compared to the macroscopic area of the electrode itself. For a biosensor application, the array electrode was tested for $H_2O_2$ detection and showed very sluggish electrochemical response to $H_2O_2$. To enhance the detection efficiency to the oxidation of $H_2O_2$, gold was treated on the electrode by two different approaches: sputtering and electrochemical deposition. Gold treatment with either method greatly enhanced the sensitivity of the electrode to $H_2O_2$. So, conducting polymer microtubule array with gold treatment was expected to be a sensitive amperometric biosensor system based on the detection of $H_2O_2$.

Synthesis and Characterization of Non-precious Metal Co-PANI-C Catalysts for Polymer Electrolyte Membrane Fuel Cell Cathodes (고분자 전해질 연료전지 캐소드용 코발트-폴리아닐린-탄소로 구성된 비귀금속 촉매의 제조 및 특성 평가)

  • Choi, Jong-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • In order to overcome the cost issue for commercialization of polymer electrolyte membrane fuel cell (PEMFC), this research was conducted for replacing platinum cathode catalyst with non-precious metal catalyst. The non-precious metal catalyst (Co-PANI-C) was synthesized by the simple reduction method with polyaniline (PANI), carbon black, and cobalt precursor without any heat treatment. Characterization of new Co-PANI-C composite catalysts was done by the measurement of X-ray diffraction (XRD) and thermogravimetric analysis (TGA) for structure analysis and performed by rotating disk electrode (RDE) and rotating ring disk electrode (RRDE) for electrochemical analysis. As a result, Co-PANI-C catalyst showed 60 mV lower on-set potential for oxygen reduction reaction (ORR) than Pt/C catalyst, but the overall reduction current of Co-PANI-C catalysts by ORR was still smaller than that of Pt/C. In addition, the ORR behavior of Co-PANI-C catalysts depending on the rotation speed of electrode and the stability of Co-PANI-C catalyst under potential cycling and the performance of fuel cell conditions are also discussed.

Joint Displacement Resistance Evaluation of Waterproofing Material in Railroad Bridge Deck (철도교량상판 방수재료 선정을 위한 균열거동저항 성능평가)

  • Bae, Young-Min;Oh, Dong-Cheon;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.683-692
    • /
    • 2020
  • A joint displacement resistance evaluation method for selecting waterproofing materials in railway bridge decks is proposed. The displacement range for an evaluation is determined by finite element method (FEM) analysis of a load case based on an existing high-speed PSC Girder Box railroad bridge structure. The FEM analysis results were used to calculate the minimum joint displacement range to be applied during testing (approximately 1.5 mm). For the evaluation, four commonly used waterproofing membrane types, cementitious slurry coating (CSC), polyurethane coating system (PCS), self-adhesive asphalt sheet (SAS), and composite asphalt sheet (CAS), were tested, with five specimens of each membrane type. The joint displacement width range conditions, including the minimum displacement range obtained from FEM analysis, were set to be the incrementing interval, from 1.5, 3.0, 4.5, and 6.0 mm. The proposal for the evaluation criteria and the specimen test results demonstrated how the evaluation method is important for the sustainability of high-speed railway bridges.

Characteristics of CL-SPEEK/HPA Membrane Electrodes with Pt-Ni and Pt-Co Electrocatalysts for Water Electrolysis (전극 촉매 Pt-Ni 및 Pt-Co를 이용한 수전해용 공유가교 CL-SPEEK/HPA 막전극의 특성)

  • Woo, Je-Young;Lee, Kwang-Mun;Jee, Bong-Chul;Chung, Jang-Hoon;Moon, Sang-Bong;Kang, An-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.1
    • /
    • pp.26-34
    • /
    • 2010
  • The electrocatalystic prperties of Pt-Co and Pt-Ni with heteropolyacids (HPAs) entrapped in covalently cross-linked sulfonated poly(ether ether ketone) (CL-SPEEK)/HPA membranes were investigated for water electrolysis. The HP As, including molybdophosphoric acid (MoPA), and tungstophosphoric acid (TPA) were both used as membrane additives and electrocatalysts. The membrane electrode assembly (MEA) was prepared by a nonequilibrium impregnation-reduction (I-R) method. $Pt(NH_3)_4Cl_2$, $NiCl_2$ and $CoCl_2$ as electrocatalytic materials and $NaBH_4$ as reducing agent were used. I order to enhance electrocatalytic activity, the catalyst layer prepared above was electrodeposited (Dep) with HP A. Surface morphologies and physico-chemical properties of MEA were investigated by means of SEM, EDX and XRD. The electrocatalytic properties of composite membranes such as the cell voltage and coulombic charge in CV were in the order of magnitude: CL-SPEEK/MoPA40 (wt%) > CL-SPEEK/TPA30 > Nafion117. In the optimum cell applications for water electrolysis, the cell voltage of Pt/CL-SPEEK-MoPA40/Pt-Co (Dep-MoPA) and Pt/CL-SPEEK-TPA30/Pt-Co (Dep-TPA) was 1.75 Vat $80^{\circ}C$ and $1\;A/cm^2$ and voltage efficiency was 87.1%. Also, the observed activity of Pt-Co (84:16 atomic ratio by EDX) is a little higher than that of Pt-Ni (86: 14). The current density peak of electrodeposited electrodes were better a little than those of unactivated electrodes based on the same membranes.

Application Assessment of Passive Sampling to Monitor Polybrominated Diphenyl Ethers in Water Environment as Alternative Sampling Method for Grab Sampling (수계 중 폴리브롬화 디페닐에테르 모니터링을 위한 Passive Sampling 적용 및 그랩 시료채취법의 대체 활용가능성 평가)

  • Kim, Un-Jung;Seo, Chang Dong;Im, Tae-Hyo;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • PBDEs (polybrominated diphenyl ehters) are rarely dissolved in water due to their strong hydrophobicity and large molecular mass so not many researches were done in aqueous environment compared to other environmental compartments. However, the mass loading from wastewater treatment plant into aquatic environment, re-suspension from bottom sediment and partitioning from floating particles and colloids may not be negligible. It is, therefore, important but also difficult to investigate PBDEs in water environment. Recent overcoming resolution towards this barrier to monitor hydrophobic organic compounds in aquatic environment is using passive sampling technique like semipermeable membrane device. By using passive sampling, it might be possible to obtain long-term reproducible monitoring result and detect the trace amounts of PBDEs, with controlling fluctuation of surrounding environmental factors during the sampling event. So therefore, this study is purposed to confirm the possibility of using SPMD (semi-permeable membrane device) as water monitoring tool. Grab samples, composite samples and SPMDs were applied in river bank to evaluate the concentration difference and temporal fluctuation by various water sampling method, and to assess the water concentration prediction capability of SPMD for the PBDEs.

A Fundamental Study on Induction Technology of Separation Behavior Using Two-sided Adhesion of Joint of Composites Waterproofing System (시트-도막 복합방수공법의 접합부 2면 접착을 통한 분리거동 유도 기술에 관한 기초적 연구)

  • Park, Jin-Sang;Lee, Tae-Yang;Kim, Dong-Bum;Park, Wan-Goo;Heo, Neung-Hoe;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.212-219
    • /
    • 2015
  • This study focuses evaluating the efficiency and performance evaluation of composite type sheet-membrane waterproofing method that utilizes a separation behavior inducement system designed to resolve the chronic problems of disintegration and damage of overlap areas of waterproofing layers. As the result of the test, the tensile strength value was at 13.8N/mm and elongation rate at 587% for the separation behavior inducement type specimen, and the compared specimens had 14.2N/mm for tensile strength and 335% for elongation rate. For the separation behavior adhesion method specimen, when tensile stress or displacement occurred, the Zero-Span tension occurrence did not follow, which resulted in that the bottom sheet layer and the top membrane layer did not simultaneously becoming damaged. When undergoing the top and bottom layers were separated through separation behavior due to lack of flexibility, the bottom layer began to damage at the primary stage, and with the allowed boundary the upper membrane layer began to display flexibility and showed continuous displaced resulting in secondary phase damaging.

Fabrication of Silane-crosslinked Proton Exchange Membranes by Radiation and Evaluation of Fuel Cell Performance (방사선을 이용한 실란 가교구조의 유/무기 복합 수소이온 교환막 제조 및 연료전지 성능 평가)

  • Lee, Ji-Hong;Sohn, Joon-Yong;Shin, Dong-Won;Song, Ju-Myung;Lee, Young-Moo;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.525-530
    • /
    • 2012
  • In this study, silane-crosslinked organic/inorganic composite membranes were prepared by simultaneous irradiation grafting of binary monomer mixtures (styrene and 3-(trimethoxysilyl)propyl methacrylate (TMSPM)) with various compositions onto a poly(ethylene-alt-tetraethylene) (ETFE) film and followed by sol-gel processing and sulfonation to provide a silane-crosslinked structure and a proton conducting ability, respectively. The Fourier transform infrared spectroscopy (FTIR) and thermo gravimetric analysis (TGA) were utilized to confirm the crosslinking of ETFE-g-PS/PTMSPM films. The prepared membranes with similar ion exchange capacity but a different TMSPM content were selected and their membrane properties were compared. The ETFE-g-PSSA/PTMSPM membranes were characterized by water uptake, dimensional stability, and proton conductivity after sulfonation. The membrane electrode assemblies (MEA) of the prepared membranes were fabricated and their single cell performances were measured.

Fabrication of a palladium alloy composite membrane by vacuum electrodeposition (Vacuum electrodeposition에 의한 팔라듐 합금 금속막 제조 및 수소 분리에 관한 연구)

  • 남승은;이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.96-98
    • /
    • 1998
  • 1. 서론 : 팔라듐이나 이의 합금막들은 높은 선택적 투과특성으로 인해 수소 정제나 분리막 반응기와 같은 산업응용 분야에서 매우 높은 관심을 갖고 있다. 상업적으로 이용되고 있는 이러한 막들은 통상적인 metallugical process에 의해 제조괸 self-supported type으로 수소 투과 속도가 낮을 뿐만 아니라 팔라듐 등은 고가의 귀금속이므로 비경제적이다. 따라서 현재 대부분의 연구자들은 기계적 강도를 유지하기 의한 다공성 지지체 위에 얇은 금속 박막을 코팅함으로서 투과성을 높이는 동시에 경제적인 복합막 형태의 막을 만드는데 연구의 촛점을 맞추고 있다. 이러한 형태의 막을 제조하기 위한 금속 박막 제조법은 무전해 도금법(electroless deposition), 화학증착법(CVD), 스퍼터링(sputtering), 전해도금법(electrodeposition) 등이 시도되었다. 그러나 수소에 대한 우수한 선택적 투과 특성을 갖기 의해서는 대부분 5$\mu$m 이상의 두꺼운 막을 제조하였으며 이보다 얇은 막의 제조에 한계가 있기 때문에 이들 막에 대한 기체 투과 특성에 대한 연구결과는 많지 않다. 본 연구에서는 기존의 전기도금법을 응용한 소위 'vacuum electrodeposition' 이란 새로운 기술을 도입함으로써 우수한 선택적 투과성을 갖는 2$\mu$m 이하의 팔라듐 합금 박막 제조를 가능하게 하였다. 지지체 표면의 거칠음 정도, 평균 기공 크기 등의 지지체 성질의 조절에 의한 금속 박막의 핀홀을 최소화함으로써 질소와 같은 inert gas의 투과도는 거의 없게 유지하는 동시에 금속 박막 두께, 결정 구조(e.g. grain size), 합금 조성 등을 조절함으로써 수소의 투과도를 높이고자 하였다. 있다. 후자의 경우, 미량의 과산화수소수 (1~10,000 ppm)를 이용해 처리 해주는 방법의 경우 경제적으로 큰 장점이 있고, 처리가 단순하다는 장점이 있으나 과산화수소수 자체에 포함하고 있는 높은 impurit level, 그리고 처리후 장시간의 flushing time을 가져야 한다는 단점등이 존재 하고 있다.요구된다. 몰입이 가능하여 임계치가 저하된 것으로 여겨진다. 또한 광학적 이득의 존재는 이 구조에 의한 극단파장 반도체 레이저다이오드의 실현 가능성을 나타내는 것이다.548 mL에 비해 통계학적으로 의의 있게 적었다(p<0.05). 결론: 관상동맥우회로 조성수술에서 전방온혈심정지액을 사용할 때 희석되지 많은 고농도 포타슘은 fliud overload와 수혈을 피하고 delivery kit를 사용하지 않음으로써 효과적이고 만족할 만한 심근보호 효과를 보였다.를 보였다.4주까지에서는 비교적 폐포는 정상적 구조를 유지하면서 부분적으로 소폐동맥 중막의 비후와 간질에 호산구 침윤의 소견이 특징적으로 관찰되었다. 결론: 분리 폐 관류는 정맥주입 방법에 비해 고농도의 cisplatin 투여로 인한 다른 장기에서의 농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술

  • PDF

Biodentine-a novel dentinal substitute for single visit apexification

  • Nayak, Gurudutt;Hasan, Mohammad Faiz
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.120-125
    • /
    • 2014
  • Use of an apical plug in management of cases with open apices has gained popularity in recent years. Biodentine, a new calcium silicate-based material has recently been introduced as a dentine substitute, whenever original dentine is damaged. This case report describes single visit apexification in a maxillary central incisor with necrotic pulp and open apex using Biodentine as an apical barrier, and a synthetic collagen material as an internal matrix. Following canal cleaning and shaping, calcium hydroxide was placed as an intracanal medicament for 1 mon. This was followed by placement of small piece of absorbable collagen membrane beyond the root apex to serve as matrix. An apical plug of Biodentine of 5 mm thickness was placed against the matrix using pre-fitted hand pluggers. The remainder of canal was back-filled with thermoplasticized gutta-percha and access cavity was restored with composite resin followed by all-ceramic crown. One year follow-up revealed restored aesthetics and function, absence of clinical signs and symptoms, resolution of periapical rarefaction, and a thin layer of calcific tissue formed apical to the Biodentine barrier. The positive clinical outcome in this case is encouraging for the use of Biodentine as an apical plug in single visit apexification procedures.

Immobilization of oxidative enzymes onto Cu-activated zeolite to catalyze 4-chlorophenol decomposition

  • Zol, Muhamad Najmi Bin;Shuhaimi, Muhammad Firdaus Bin;Yu, Jimin;Lim, Yejee;Choe, Jae Wan;Bae, Sungjun;Kim, Han S.
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.195-200
    • /
    • 2020
  • In this study, a biocatalyst composite was prepared by immobilizing oxidoreductases onto Cu-activated zeolite to facilitate biochemical decomposition of 4-chlorophenol (4-CP). 4-CP monooxygenase (CphC-I) was cloned from a 4-CP degrading bacterium, Pseudarthrobacter chlorophenolicus A6, and then overexpressed and purified. Type X zeolite was synthesized from non-magnetic coal fly ash using acetic acid treatment, and its surfaces were coated with copper ions via impregnation (Cu-zeolite). Then, the recombinant oxidative and reductive enzymes were immobilized onto Cu-zeolite. The enzymes were effectively immobilized onto the Cu-zeolite (79% of immobilization yield). The retained catalytic activity of CphC-I after immobilization was 0.3423 U/g-Cu-zeolite, which was 63.3% of the value of free enzymes. The results of this study suggest that copper can be used as an effective enzyme immobilization binder because it provides favorable metalhistidine binding between the enzyme and Cu-zeolite.