• Title/Summary/Keyword: concrete-filled tubular flange

Search Result 23, Processing Time 0.026 seconds

Experimental study on shear behavior of I-girder with concrete-filled tubular flange and corrugated web

  • Shao, Y.B.;Wang, Y.M.
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1465-1486
    • /
    • 2016
  • Conventional plate I-girders are sensitive to local buckling of the web when they are subjected mainly to shear action because the slenderness of the web in out-of-plane direction is much bigger. The local buckling of the web can also cause the distorsion of the plate flange under compression as a thin-walled plate has very low torsional stiffness due to its open section. A new I-girder consisted of corrugated web, a concrete-filled rectangular tubular flange under compression and a plate flange under tension is presented to improve its resistance to local buckling of the web and distorsion of the flat plate flange under compression. Experimental tests on a conventional plate I-girder and a new presented I-girder are conducted to study the failure process and the failure mechanisms of the two specimens. Strain developments at some critical positions, load-lateral displacement curves, and load-deflection curves of the two specimens have all be measured and analyzed. Based on these results, the failure mechanisms of the two kinds of I-girders are discussed.

Stress analysis of a new steel-concrete composite I-girder

  • Wang, Yamin;Shao, Yongbo
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.51-61
    • /
    • 2018
  • A new I-girder consisted of top concrete-filled tubular flange and corrugated web has been proved to have high resistance to both global buckling of the entire girder and local buckling of the web. This study carries out theoretical analysis and experimental tests for this new I-girder to investigate the stress distribution in the flanges and in the corrugated web. Based on some reasonable assumptions, theoretical equations for calculating the normal stress in the flanges and the shear stress in the corrugated web are presented. To verify the accuracy of the presented equations, experimental tests on two specimens were carried out, and the experimental results of stress distribution were used to assess the theoretical prediction. Comparison between the two results indicates that the presented theoretical equations have enough accuracy for calculating the stress in the new I-girder, and thus they can be used reliably in the design stage.

An experimental study of connections between I-beams and concrete filled steel tubular columns

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.303-315
    • /
    • 2004
  • Frame composed of concrete-filled steel tubular columns and I-shaped steel beam has been researched in order to development reasonable connection details. The present paper describes the results of an experimental program in four different connection details. The connection details considered include through-bolt between I-shaped steel beams and concrete-filled steel tubular columns and two details of welded connections. One of the welded connection details is stiffened by angles welded in the interior of the profile wall at the beam flange level. The specimens were tested in a cruciform loading arrangement with variable monotonic loading on the beams and constant compressive load on the column. For through-bolt details, the contribution of friction and bearing were investigated by embedding some of the bolts in the concrete. The results of the tests show that through-bolt connection details are very ductility and the bearing is not important to the behavior of these moment connections. The angles welded in the interior of the profile wall increase the strength and stiffness of the welded connection detail. In addition, the behavior curves of these connections are compared and some interesting conclusions are drawn. The results are summarized for the strength and stiffness of each connection.

Tensile Behavior of Concrete-Filled Square Steel Tubular Column-Beam Flange Connections with Stiffeners (강관 보강형 충전 각형강관 기둥-보 플랜지 접합부의 인장거동에 관한 실험적 연구)

  • Yoo, Yeong Chan;Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • The purpose of this study is to examine the utility of concretefilled steel tubular column to H-beam connections with tubular stiffener. As a preliminary step. a tensile experiment was undertaken to scrutinize characteristics of the structural behavior that take place between beam flanges and column with tubular stiffener. A total of 4 types of experimental settings were developed as tabular stiffeners are made up 9, 18, and 27 mm of thickness and 50 and 80 mm of height respetively Along with the overall load subsequently the degree of displacement and strain were recorded. Based on the yield line theory results of this of this study were evaluated and further critically reviewed the applicability of the strength formula. This study found that collapse mechanism was emerged on the beam flange as reinforcing tabular stiffeners Complementary studies of this sort, including numerical analyses should be undertaken in order to develope specific design critera.

  • PDF

Experimental Study on the Structural Behavior of Concrete-Filled Circular Tubular Column to H-Beam connections without Diaphragm (다이아프램이 없는 콘크리트 충전 원형강관 기둥-H형강 보 접합부의 구조적 거동에 관한 실험적 연구)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.13-22
    • /
    • 1997
  • This paper is concerned with an experimental study on structural behavior of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections. The important parameters are the number of inner reinforced rib and the width of H-beam flange(100, 150, 200mm) with variable column thickness(5.8mm, 9.2mm, 12.5mm) around the joint between CFCT and H-beam. Test results are summarized for the displacement, strength, initial stiffness, failure mode and energy absorption capacity of each specimen. The purpose of this paper is to investigate the initial stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections. From the discussion about the test results, the basic data for non diaphragm connection design would be suggested.

  • PDF

Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Exterior Diaphragm (외부다이아프램으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동)

  • Yoo, Yeong Chan;Lee, Seung Joon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.205-220
    • /
    • 1997
  • The objective of this study is to investigate the structural behavior of concrete-filled steel tubular column-H beam connections with exterior stiffeners. As a preliminary test, simple tensile test on the column to H-beam flange connections stiffened were conducted The paramaters of tensile test are the thickness(T=9, 12, 15m) and the width(W=50, 75, 100, 150mm) of exterior stiffeners. The simple tensile test were conducted to 7 kinds of specimens. Estimating the load, displacement, and strain from each kind, results of simple tensile test were compared with results of second test. On the basis of simple tensile test, test on the column to H-km connections stiffened with the sames under monotonic and cyclic load were conducted. Specimens of 5 for the second experiment were made. In analysis, comparing each strengthes and stiffnesses we estimated deformation capacity. Comparing and estimating each yielding strength ratios and maxium-strength ratios on the basis of yield line theory, new strength formula of beam-to-column connections was suggested.

  • PDF

Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Plates (강판보강 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동)

  • Yoo, Yeong Chan;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.161-175
    • /
    • 1998
  • The objective of this study is to investigate the structural behavior of Concrete-Filled Steel Tubular Column-H Beam connections with plate stiffeners. The first, we made experiment on the Column to H-beam flange connections stiffened with simple tensile loading. The paramaters of tensile experiment are the area of each plates. The simple tensile experiment is conducted to 5 kinds of specimens. Eestimating the load, displacement, and strain from each kind, we compared them with results of second experiment. The second, we made experiment on the Column to H-beam connections stiffened with the sames under monotonic and cyclic load. we made specimens of 5 for the second experiment. In analysis, comparing each strengthes and stiffnesses we estimated deformation capacity. Comparing and estimating each yielding strength ratios and maxium-strength ratios on the basis of Yield line theory, we suggested new Strength Formula of Beam-to-Column Connections.

  • PDF

Seismic behavior of full-scale square concrete filled steel tubular columns under high and varied axial compressions

  • Phan, Hao D.;Lin, Ker-Chun
    • Earthquakes and Structures
    • /
    • v.18 no.6
    • /
    • pp.677-689
    • /
    • 2020
  • A building structural system of moment resisting frame (MRF) with concrete filled steel tubular (CFST) columns and wide flange H beams, is one of the most conveniently constructed structural systems. However, there were few studies on evaluating seismic performance of full-scale CFST columns under high axial compression. In addition, some existing famous design codes propose various limits of width-to-thickness ratio (B/t) for steel tubes of the ductile CFST composite members. This study was intended to investigate the seismic behavior of CFST columns under high axial load compression. Four full-scale square CFST column specimens with a B/t of 42 were carried out that were subjected to horizontal cyclic-reversal loads combined with constantly light, medium and high axial loads and with a linearly varied axial load, respectively. Test results revealed that shear strength and deformation capacity of the columns significantly decreased when the axial compression exceeded 0.35 times the nominal compression strength of a CFST column, P0. It was obvious that the higher the axial compression, the lower both the shear strength and deformation capacities were, and the earlier and faster the shear strength degradation occurred. It was found as well that higher axial compressions resulted in larger initial lateral stiffness and faster degradation of post-yield lateral stiffness. Meanwhile, the lower axial compressions led to better energy dissipation capacities with larger cumulative energy. Moreover, the study implied that under axial compressions greater than 0.35P0, the CFST column specimens with B/t limits recommended by AISC 360 (2016), ACI 318 (2014), AIJ (2008) and EC4 (2004) codes do not provide ultimate interstory drift ratio of more than 3% radian, and only the limit in ACI 318 (2014) code satisfies this requirement when axial compression does not exceed 0.35P0.

Non-linear Analysis of Full Scaled CFT Column to H-Beam Connections with T-Stiffeners (T 스티프너를 이용한 CFT기둥-H 형강보 실대형 접합부의 비선형 해석)

  • Lee, Seung Woo;Kim, Young Joo;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.835-843
    • /
    • 2002
  • The goal of this paper is to understand the stress-transfer mechanism of concrete-filled tubular column to H-beam connection with external T stiffener through the elasto-plastic finite element method and to offer basic data for the design of T stiffener. For the accuracy, analysis results are compared with experimental results. It makes use of several stress and strain indices to understand the stress-transfer mechanism of connection. An alternative plan that decreases the stress concentration of beam flange to horizontal stiffener connection is proposed through the elasto-plastic finite element method.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.