Experimental Study on Interface Shear Strength of Concrete in Vertical Construction Joint (콘크리트 수직시공이음 접합면의 전단강도에 대한 실험적 연구)

  • Kim, Ook-Jong;Kim, Young-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.125-129
    • /
    • 2004
  • In masive concrete placement, cracking problem due to hydration heat is frequently encountered. One of measure to solve this problem is to make a construction joint. However, it is cumbersome to make it by chipping the surface of joint. In this study, push-out test for 18 specimens was conducted to compare the interface shear strength of consturction joints whose surfaces were prepared with three methods; chipping, rib-lath, folded rib-lath. Compared to the specimens made with conventional surface chipping, those with rib-lathe showd excellent preformance increasing shear resistance capacity and the role of shear key conceived by folding rib-lath played important role in enhancing shear resistance.

Compressive Strength Control of High Strength Concrete Using Transparent Joint Separation Test Body (투명접합분리 시험체를 활용한 고강도 콘크리트의 강도관리에 관한연구)

  • Ki, Jun-Do;Jung, Kwang-Sik;Kim, Hak-Young;Kim, Kwang-Ki;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.49-52
    • /
    • 2009
  • This paper aims to evaluate hydration and intensity property of different kind of members and intensity in order to evaluate compressive strength of structural concrete using Joint Separation Test Body(JSTB). In fact it is difficult to test and evaluate already have constructed member. In this case, common method used by construction engineer is that ; Schmidt rebound hammer test, Ultrasonic pulse test, Method of using test specimen previously cast. However, these method to control the structural intensity involve many problem and impossibility to adapt construction. 80, this paper proposes advance an opinion which have proper to examine intensity. has also aims to examine its validity and the plan to make similar environment with structural concrete and joint separation test body in order to verify efficiency assessment and on-site application.

  • PDF

A Case Study on the Application of Echelon Paving Method Using a 12m-Wide Screed Finisher on Flexible Airfield Pavements (광폭 Echelon 공법의 연성 활주로 포장 적용에 관한 사례 연구)

  • Jeon, Kook-Il;Choi, Heung-Sup;Bin, Cheol-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.353-356
    • /
    • 2007
  • Asphalt pavements of the airport in service were monitored to construct new runway and taxiway and longitudinal cracks were found on the pavements. The sources of the longitudinal cracks were the low density which was caused by the longitudinal cold joint with asphalt Pavement constructions and the excessive loads of aircraft. Therefore, the echelon paving method using a 12m-wide screed finisher was used to eliminate longitudinal cracks. When the echelon paving is used, construction of the longitudinal joint is changed so that the compaction of the unconfined edge of the first lane is delayed until the second lane is placed. In conclusion, the use of this construction method results in the density of the longitudinal joint being equal to that of the adjacent mat.

  • PDF

A Study on the Effective Operation Model of Joint-Venture Contract - With a Focus on the Example of Domestic Construction Industry - (효율적인 공동도급 운영모델에 관한 연구 -국내 대규모 건축공사 사례를 중심으로-)

  • Suhr Myong Suk;Kim Moo Han
    • Korean Journal of Construction Engineering and Management
    • /
    • v.3 no.3 s.11
    • /
    • pp.103-111
    • /
    • 2002
  • A joint venture approach to the marketing, organization, and execution of a project should be considered when the combined strengths of two or more entities result in a joint organization with unique credentials in a targeted business area. A joint venture is based on a complementary relationship: one party may lack one or more major elements needed for market penetration, such as technology, design-construct capabilities, geographic location, or financial strength; the other party should be able to compensate for these areas of weakness. The purpose of this study is that suggests the development direction of a joint venture, the proper organizational approach

Experimental study on simplified steel reinforced concrete beam-column joints in construction technology

  • Teraoka, Masaru;Morita, Koji;Sasaki, Satoshi;Katsura, Daisuke
    • Steel and Composite Structures
    • /
    • v.1 no.3
    • /
    • pp.295-312
    • /
    • 2001
  • The purpose of this paper is to propose a new type of steel reinforced concrete (SRC) beam-column joints and to examine the structural performance of the proposed joints, which simplify the construction procedure of steel fabrication, welding works, concrete casting and joint strengthening. In the proposed beam-column joints, the steel element of columns forms continuously built-in crossing of H-sections (${\Box}$), with adjacent flanges of column being connected by horizontal stiffeners in a joint at the level of the beam flanges. In addition, simplified lateral reinforcement (${\Box}$) is adopted in a joint to confine the longitudinal reinforcing bars in columns. Experimental and analytical studies have been carried out to estimate the structural performance of the proposed joints. Twelve cruciform specimens and seven SRC beam-column subassemblage specimens were prepared and tested. The following can be concluded from this study: (1) SRC subassemblages with the proposed beam-column joints show adequate seismic performances which are superior to the demand of the current code; (2) The yield and ultimate strength capacities of the beam-to-column connections can be estimated by analysis based on the yield line theory; (3) The skeleton curves and the ultimate shear capacities of the beam-column joint panel are predicted with a fair degree of accuracy by considering a simple stress transfer mechanism.

The Properties for Structural Behavior of Beam-Column Joint Consisting of Composite Structure (혼합구조로 이루어진 보-기둥 접합부의 구조적 거동 특성)

  • Lee, Seung Jo;Park, Jung Min;Kim, Wha Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.445-455
    • /
    • 2000
  • This study proposed to beam-column joint model consisting of different type structural member to develop new structural system in the structural viewpoint as to a method to overcome various problem according to change of construction environment. This study promoted rigidity and capacity to stiffen reinforced concrete for steel structure end to increase rigidity of long spaned steel beam, and welt to steel flange to anchor U-shaped main bar of SRC structure end to easy stress flow between the different type structure. Through the series of experiments, proposed to possibility of this joint model, and investigated joint rigidity and capacity.

  • PDF

A basic study of steel-joint connection method of composite precast concrete members (합성 PC부재의 Steel-joint Connection Method 개발 기초연구)

  • Kim, Geun-Ho;Lee, Dong-Hoon;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.10-11
    • /
    • 2013
  • Green Frame is a column-beam system formed by composite precast concrete column and beam connected with steel buried in both members. During the installation of Green columns, the columns of Green Frame, covering 3 floors per each piece and beams, the eccentricity can be observed due to the construction error and the weight of beam itself. Such eccentricity may have a little influence on a single frame, yet, it can develop critical issues to the installation of subsequent beams or beams on the upper floors in the context of a building as a whole that has multiple frames. These issues lead to delay in frame installation, decrease of productivity and increase of cost, etc. Therefore, this study presents a steel-joint connection method in order to solve the issues. The steel-joint connection method exists on slope plane and reinforcing plate in steel frame buried in composite PC members. Through this method, the issues can be resolved without requiring additional equipment or manpower.

  • PDF

An Experimental Study on Allowable Size of Incomplete Penetration in Butt Joint Bridge Weld Considering Fatigue Strength (교량의 피로강도를 고려한 맞대기용접부 불안전용입 한계결함 결정에 관한 연구)

  • 백영남;장영권
    • Journal of Welding and Joining
    • /
    • v.18 no.3
    • /
    • pp.68-75
    • /
    • 2000
  • The incomplete penetration(IP) discontinuity in butt joint weld, which is detected during safety analysis of the steel bridge by nondestructive evaluation(NDE) method, is classified as unacceptable defect according to the NDE codes and standards. In fact, there are a little allowance in butt joint weld in the view point of design criterion, and also detected IP discontinuity should be classified and evaluated for the fatigue strength and residual life estimation. In this study, we performed fatigue test to evaluate the fatigue strength of high strength steel(SWS490A) containing IP discontinuities in various size, the results compared and classified according to the bridge construction standard specification which published by korea administration of construction and traffic. Experimental results could be used to evaluate and estimate the IP discontinuities considering different stress range in butt joint bridge weld during periodic safety inspection.

  • PDF

Compressive Strength of Horizontal Joints Pocket in Precast Concrete Large Panel System (대형판 PC 구조 시스템의 수평접합부 충전부위 구조성능에 관한 실험연구)

  • Yoo, Seong-Hoon;Cho, Seung-Ho;Park, Hyun-Soo;Euh, Yang-Suk;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.597-602
    • /
    • 1997
  • The compressive strength of horizontal joints in precast concrete large panel structures depends on parameters such as grout and panel strength, detail of joint, joint moment, width of grout column etc. As the panels are only connected at the pocket, it results in the reduction of compressive strength area. The purposes of this study are to develop the suitable grout material the joint pocket and to enable us to evaluate structural capacity. The validity of the design formulas provides us more economic system in construction. Test results of 15 specimens show that the proper construction procedure and grouting material develop the sufficient compressive strength of the wall as monolithic system.

  • PDF

An Experimental Study on Bond Properties the ways of Disposal Horizontality Placing Joint of Concrete Structure (콘크리트 구조체의 수평 이어치기 처리방법별 부착성에 관한 실험적 연구)

  • Kim, Doo-Bea;Heo, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.1-4
    • /
    • 2006
  • Because do placing joint after smallest $1{\sim}3$ day about concrete that is placed beforehand in field, it is difficult that remove laitance happening harden concrete. This laitance happens a problem of bond properties, deterioration in strength. In this research got following conclusion as result that do research about bond properties the way of disposal placing joint. Air Jet is loft interior and exterior. Water Jet appeared that laitance Removal Capacity is superior to dimension within 5%. Deterioration in strength is measured 37% by splitting tensile strength test result by laitance. Deterioration in strength by laitance do more than 30% that removal of laitance is predicted must consist necessarily at concrete horizontality placing joint stroke.

  • PDF