• Title/Summary/Keyword: contaminated ground water

Search Result 119, Processing Time 0.024 seconds

Treatment of the fuel oxygenate, MTBE, contaminated ground water using Sequence Batch Bioreactor

  • ;Robert M. Cowan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.92-95
    • /
    • 2000
  • A mixed bacterial culture capable of mineralizing methyl tort-butyl ether (MTBE), other fuel oxygenates ethers, tertiary carbon alcohols, benzene and toluene was used to inoculate batch reactor and sequence batch reactor (SBR) to treat gasoline contaminated ground water containing about 60 mg/L MTBE, 5 mg/L benzene, 5 mg/L toluene, and low concentrations of several other aromatic and aliphatic hydrocarbons. Respirometery studies showed that MTBE degrading mixed culture could treat MTBE contaminated ground water with addition of nitrogen and phosphate. SBR was operated to demonstrate the feasibility of using suspended growth activated system for the treatment of ground water and to confirm that the respirometry derived kinetics and stoichiometric coefficients were useful for predicting reactor performance. Theoretical performance of the reactor was predicted using mathematical models calibrated with biokinetic parameters derived from respirometry studies.

  • PDF

Epidemiologic Investigation to Identify the Cause of an Infant Methemoglobinemia (서울 S지역에서 발생한 영아 메트헤모글로빈혈증 1례의 원인구명을 위한 역학조사)

  • Kim, Young-Yeul;Choi, Bo-Youl;Park, Hang-Bae;Kim, Min-Young;Yeo, In-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.192-201
    • /
    • 1993
  • Epidemiologic investigation was conducted on January, 1993 in Seoul to identify the cause of an infant methemoglobinemia. Field investigation of the area of outbreak, survey of household and family members, analysis of ground water, and blood tests of involved family members were performed. Following results were obtained On analyzing the quality of the ground water on patient's household high levels of nitrate was found indicating contamination of water as the cause of a methemoglobinemia outbreak. On analysing the quality of the ground waters on seven other places within the neighborhood five were contaminated by nitrate in concentration that exceeded the permissible limit implying presence nearby source of contamination. Sources of contamination were thought to be originating from human waste in conventional bathroom facilities, chicken manure used in nearby orchards and plant fields or fertilizers. But the results of water analysis with presence of bacteria or E.coli, concentration of potassium, phosphate and the past history of diarrhea among family members, chicken manure suggested the most possible source of contamination. To evaluate the health status of members in the neighborhood past history was reviewed revealing no prior existence of patient with cyanosis and 65 people in the neighborhood had normal levels of methemoglobin concentration in their blood. Conclusively, the ground water on patient's household was contaminated with nitrate and despite provision of adequate water supply, family members of the patient along with their distrust in the water supply system had used ground water as their source of drinking water resulting of methemoglobinemia. Many suburban area of Seoul and country side thought to be having similar problems concerning contaminated ground water supply and dormant outbreak of patients as a result of the drinking of the contaminated water. Epidemiologic investigation and water analysis of ground waters are advised.

  • PDF

다중 환경추적자를 이용한 제주도 지하수 유동 및 수질 특성 분석

  • 고동찬;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.138-141
    • /
    • 2004
  • The environmental tracers tritium/helium-3 (3H/3He) and chlorofluorocarbons (CFCs) were investigated in ground water from Jeju Island, Korea, a basaltic volcanic island. The apparent 3H/3He and CFC-12 ages were in relatively good agreement in samples with low concentrations of terrigenic He. Ground water mixing was evaluated by comparing 3H and CFC-12 concentrations with mixing models, which distinguished old water with negligible 3H and CFC-12, young water with piston flow, and binary mixtures of the two end members. The ground water CFC-12 age is much older in water from wells completed in confined zones of the hydro-volcanic Seoguipo formation in coastal areas than in water from the basaltic aquifer. Comparison of major element concentrations in ground water with the CFC-12 age shows that nitrate contamination processes contribute more solutes in young water than are derived from water-rock interactions in non-contaminated old water. Chemical evolution of ground water resulting from silicate weathering in basaltic rocks reaches the zeolite-smectite phase boundary. The calcite saturation state of ground water increased with the CFC-12 apparent (piston flow) age. In agricultural areas, the temporal trend of nitrate concentration in ground water was consistent with the known history of chemical fertilizer use on Jeju Island, but the response of nitrate concentration in ground water to nitrogen inputs follows an approximate 10-year delay. Based on mass balance calculations, it was estimated that about 40% of the nitrogen applied by fertilizers reached the water table and contaminated ground water resources when the fertilizer use was at the highest level.

  • PDF

Biological Monitoring of Arsenic Concentrations According to Exposure to Arsenic-contaminated Ground Water (모 지역 소규모급수시설 비소검출에 따른 생물학적 노출 평가)

  • Seo, Jeong-Wook;Choi, Jae-Won;Oh, Yu-jin;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.513-524
    • /
    • 2020
  • Objective: The main purpose of this study is to evaluate the environmental and biological exposure of local residents who consumed arsenic-contaminated drinking water for less than one year. Methods: As a part of water quality inspections for small-scale water supply facilities, surveys were conducted of residents of two villages that exceeded the arsenic threshold for drinking water. The environmental impact survey consisted of surveys on water quality, soil, and crops in the surveyed area. Biological monitoring was performed by measuring the separation of arsenic species in urine and total arsenic in hair. Results: In the results of biological monitoring, the concentrations of AsIII and AsV were 0.08 and 0.16 ㎍/L, respectively. MMA and DMA were 0.87 and 36.19 ㎍/L. There was no statistically significant difference between the group who drank arsenic-removed groundwater or water from the small-scale supply facility and the group who drank tap water, purified water, or commercial bottled water. Some of the water samples exceeded the arsenic threshold for drinking water. There were no samples in the soil or rice that exceeded the acceptable threshold. Conclusion: In the case of short-term exposure to arsenic-contaminated drinking water for less than one year, there were no significant problems of concern from the evaluation of biological monitoring after arsenic was removed.

Experimental Study on Freezing Soil Barrier Wall for Contaminant Transfer Interception (오염물질 이동 차단을 위한 동결차수벽 형성에 관한 실험적 연구)

  • Shin, Eun-Chul;Kim, Jin-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2011
  • The purpose of this study was to prevent spreading of contaminants from movement of underground water by creating a barrier using artificial freezing method on a soil contaminated by oils and various DNAPLs. Specimens with 80% and 90% degrees of saturation were prepared to form freezing barrier using artificial freezing method. As the results of freezing specimen within soil bin with artificial ground freezing system, artificial contaminated soil cut off wall formed the thinnest wall after 12 hours. It is judged that this cut off wall will control the second soil pollution by intercepting expansion and movement of pollutants and DNAPLs within artificial contaminated soil cut off wall by underground water, intercepting inflow or outflow of underground water. Cut off walls formed by artificial ground freezing system had each other freezing speed according to degree of saturation.

A study of the pollution of ground water in the basin of the river Baem Nae Chun, Sorae-Myun, Shihoong-gon, Kyonggi-Do, Korea (경기도 시흥군 소래면 뱀내하천 유역의 지하수 오염에 관한 연구)

  • 김윤종;정봉일
    • Water for future
    • /
    • v.6 no.2
    • /
    • pp.19-29
    • /
    • 1973
  • The progressive contamination of water resulted from man's activity and the use of fertilizers is not restricted only to surface water, but also the shallow groundwater is affected. This type of groundwater contamination is mainly restricted to areas composed of permeable, nonconsolidated sediments forming a shallow aquifer. The chloride and the sulfate resulted from man's activity and the use of fertilizers were measured to study the variations of the groundwater contamination. In general, (1) When water level rises, the rate of groundwater contamination becomes less and when water level declines, the rate of contamination is increased. (2) The highly contaminated season is the early-summer and the less contaminated season is the winter or after rainy season. (3) The groundwater in weathering zone without covering layer. (4) The degree of contamination of wells is increased with the increase of well depth and lowing the water table, because of increasing contaminated water from enlargement of the area of influence of the well.

  • PDF

Investigation into circulation of ground water by air sparging (Air sparging에 의한 지하수 순환에 관한 연구)

  • 이준희;강구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.232-235
    • /
    • 1998
  • Air sparging system is a kind of in-situ bioremediation method in the contaminated ground water. When Air sparging, the both of water circulation and oxygen transfer happend in the same time. The hydraulic differential head is zero at the middle height of well, is negative below the height and is possitive above the height. Hydroraulic head gradient is proportioned to air superficial velocity in the well. But over 24m/min of the superficial velocity, the hydraulic head gradient increase little.

  • PDF

Determination of Icing Inhibitors (Ethylene Glycol Monomethyl Ether and Diethylene Glycol Monomethyl Ether) in Ground Water by Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang;Jung, Dong-Gyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.806-808
    • /
    • 2004
  • A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of icing inhibitors, ethylene glycol monomethyl ether and diethylene glycol monomethyl ether in ground water contaminated with JP-8. Ethylene glycol monobutyl ether and ethylene glycol monoethyl ether were used as the internal standard and surrogate, respectively. 100 mL of ground water was extracted twice with 20 mL of methylene chloride. The extract was concentrated to dryness, dissolved with 100 ${\mu}$L of methanol and analyzed by GC-MS (SIM). The use of an Innowax column gave the peaks good chromatographic properties, and the extraction of these compounds from samples gave recoveries of about 50% with small variations. The method detection limits of the target compounds were in a range of 0.5-0.8 ng/mL in ground water.