• Title/Summary/Keyword: contamination measurement

Search Result 231, Processing Time 0.029 seconds

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Yoo, Dong-Ju;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF

A Estimation of Contamination Degree by the Measurement of Phase Difference on the Outdoor Insulator (옥외절연물의 오손도 파악을 위한 위상차 측정)

  • 심규일;이원영;한상옥;박강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.443-446
    • /
    • 2002
  • In this paper, a phase difference of liveline insulator was measured and analyzed to estimate the contamination degree. The probability of accident rises according to the increase of the contamination. So the estimation of contamination degree is very important in design and maintenance of outdoor insulator. There are many methods to measure the contamination degree, but those methods use the spacial sense to measure the contamination degree. So, we have no information about the contamination from the liveline insulator, but there is a measurement of phase difference to estimate the contamination degree. The phase difference is varied with the increase of ESDD, so the contamination degree could be estimated by using those characteristics. The experiment is performed to analyze the interrelationship between contamination degree and phase difference. The variable condition is relative humidity that increases from 30 to 100 % in a chamber. We use the DAS program to measure and analyze the data. From the result, the variation of phase difference is different by the contamination degree, so we can confirm the possibility of estimating the contamination degree by the phase difference.

  • PDF

Estimation of Pollution Degree for Liveline Insulator with Leakage Current Measurement (누설전류 측정을 통한 활선 절연물의 오손도 추정)

  • Shim, Kyu-Il;Choi, Nam-Ho;Park, Kang-Sik;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1472-1474
    • /
    • 2001
  • In this paper, a method was presented to estimate the contamination degree of outdoor insulator by the measurement of surface leakage current. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, the estimation technique for contamination has been needed to monitor the accurate pollution degree of insulator in situ. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity. From the result, we could confirm the capability of the estimation method.

  • PDF

A Study on the Laser Aided Measurement of Salt Contamination of Porcelain Insulators (레이저를 이용한 활선 염해 측정)

  • Cho, C.H.;Lee, H.S.;Choi, Y.W.;Kweon, D.J.;Choi, I.H.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1807-1809
    • /
    • 1997
  • The salt contamination on the surface of the porcelain insulators used electric power systems causes flash-over accidents. Therefore the quantity of salt contamination should be monitored not to exceed a limit. In this study, we tried laser aided measurement of salt contamination. The Nd:YAG laser beam was focused on the surface of the porcelain insulators which were artificially contaminated, and we detected the D-Line (${\cong}589nm$) of spontaneous emission from the excited sodium atoms with a PMT and an oscilloscope. And we deduced the relation between the detected signals and degree of salt contamination.

  • PDF

A Fundamental Investigation to Develope a Automatic Apparatus for Contamination Measurement (오손도 자동측정장치 개발을 위한 기초연구)

  • 최남호;한상옥
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.74-82
    • /
    • 2001
  • To reduce the maintenance expense and the possibility of electric outage and/or accident, which causes the decrease in stability and reliability of transmission/distribution line, most of all, accurate measurement for the degree of contamination should be preceded. But the conventional method (brush wiping method), which is recommended in IEC 60815, has sow significant problem in the aspect of man power, expense, error, and so forth. In this investigation, we purpose the development of a new type automatic measuring apparatus, which could measure the degree of contamination on the surface of insulator in outdoor condition. To design and evaluate the apparatus, a FLUX 2D is used, and various laboratory tests, artificial contamination tests, were carried to proof the actual performance. With the result of these effort, we can get the meaningful conclusion to develope a new type automatic apparatus for contamination measurement.

  • PDF

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.45-54
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.

An Experimental Study on the Measurement of Soot Contamination in A Diesel Engine Oil (디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰)

  • Jo, Seong-Yong;Gong, Ho-Seong;Yun, Ui-Seong;Han, Heung-Gu;Jeong, Dong-Yun
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.120-129
    • /
    • 2002
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. Various laboratory tests of the detector were performed mainly with carbon black particles of different contamination levels. It was found that the proposed detector could be well used to monitor oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles to a measurement surface was considered to be a critical problem in the new detector. Effects of particle deposition onto the interface was experimentally evaluated with the oil temperature and turbulence and discussed throughout this work.

  • PDF

A Study of Radioactive Contamination in Hospital Toilet (병원 화장실의 방사성 오염에 관한 연구)

  • Kim, Ki-Jin;Kim, Gha-Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.241-246
    • /
    • 2015
  • Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is $25.69Bq/cm^2$(a restroom near admission and administration), $19.39Bq/cm^2$(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.

Contamination measurement, Analysis & Control for Satellite (인공위성의 오염 측정, 분석 및 관리)

  • Lee, Sang-Hoon;Hong, Seok-Jong;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • It is necessary to be careful about contamination control to minimize the accumulation of the contamination material on satellite surface during the I&T phase. In the space environment which characterized by high vacuum, high and very low temperature, contamination material causes satellite to lose its own performance. Especially, contamination material can accumulate on critical surfaces such as lenses, mirrors, and sensors. KARI(Korea Aerospace Research Institute) conducts the clean room to control and minimize the contamination effect. This paper introduces the principle of contamination and the method of measure and analysis for the contamination.