An Experimental Study on the Properties of Porous Concrete according to Correction Factor and Specimen Thickness (보정계수 및 시험체두께가 포러스콘크리트의 기초물성에 미치는 영향에 관한 실험적 연구)

  • 김재환;이성일;장종호;오시덕;박정호;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.55-58
    • /
    • 2002
  • This study is to analyze the influence of correction factor and specimen thickness on the fundamental properties of porous concrete. Results of this study were shown as follows; 1) As correction factor decrease, compaction time according to correction factor and specimen thickness decrease. Also, though correction factor is same, as specimen thickness increase, compaction time increase. So It mutt be considered that the influence of compaction time according to correction factor and specimen thickness. 2) As correction factor decrease, difference of measured thickness and designed thickness according to correction factor and specimen thickness decrease. Also, correction factor of aggregate of 10~l5mm is smaller than that of 5~l0mm. So It must be considered that the influence of correction factor according to size of aggregate.

  • PDF

New Speed Adjustment Factor for Analyzing Level of Service at Multi-Lane Highway (다차로도로의 서비스수준 분석을 위한 속도보정계수 개선에 관한 연구)

  • Kim, Wongil;Kang, Woneui;Noh, Chang-Gyun;Park, Bumjin
    • International Journal of Highway Engineering
    • /
    • v.14 no.6
    • /
    • pp.167-173
    • /
    • 2012
  • PURPOSES : This study is to develop speed correction factor for more realistic Level-of-Service(LOS) at multilane highway. METHODS : In this study, we compared speed difference the degree of speed reductions in actual multilane road conditions with speed reduction considering speed correction factor presented in highway capacity manual using statistical techniques. And also we presents new speed correction factor analyzing collected data at national highway No.1 (Goyang~Wolrung). RESULTS : The result of analyzing and comparing new suggested speed correction factor with speed correction factor in Korea Highway Capacity Manual (KHCM) shows RMSE (Root Mean Square Error) in new speed correction factor (RMSE 1.5) is much lower than existing speed correction factor (RMSE 13.4). New suggested speed correction can be used for analyzing Level-of-Service at multilane highway. And also we suggests improvements for analysis procedure in analyzing Level-of-Service at multilane highway CONCLUSIONS : As a result of comparing differences, we draw the causes that effect the differences in speed and suggest new speed correction factor that consider traffic volumes. It can be more rational because it uses speed correction factor which can consider more realistic traffic conditions, etc.

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Proposal of New Correction Factors for New and Renewable Energy Sources in Public Building (공공건축물에 적용되는 신·재생에너지원의 새로운 보정계수 제안)

  • Kim, Yun-Ho;Park, Yun-Ha;Won, An-Na;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.13-24
    • /
    • 2016
  • The government introduced a mandatory installation system of new & renewable energy for public building to meet the target of greenhouse gas reduction and also suggest a correction factor for new renewable energy to expand the installation of various new & renewable energy systems. The introduction of correction factors, however, was followed by the reduction of installation size of new & renewable energy sources. Assuming that it was caused by a correction factor for each new renewable energy source calculated by the initial costs, this study proposed a new correction factor approach based on payback periods to reflect the technology element in the calculation process of correction factors additionally. The application results of new correction factors show that it was possible to do complex calculations including the economic and technological aspects to select a new & renewable energy system and that the installation size was also enlarged.

Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber

  • Yu, Jili;Wu, Jinjie;Liao, Zhenyu;Zhou, Zhenjie
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1466-1472
    • /
    • 2018
  • A key comparison has been made between the air-kerma standards of the National Institute of Metrology (NIM), China, and other Asia Pacific Metrology Programme (APMP) members in the medium-energy X-ray. This paper reviews the primary standard Free-air ionization chamber correction factor experimental method and Monte Carlo simulation method in the NIM. The experimental method and the Monte Carlo simulation method are adopted to obtain the correction factor for the medium-energy X-ray primary standard free-air ionization chamber at 100 kV, 135 kV, 180 kV, 250 kV four CCRI reference qualities. The correction factor has already been submitted to the APMP as key comparison data and the results are in good agreement with those obtained in previous studies. This study shows that the experimental method and the EGSnrc simulation method are usually used in the measurement of the correction factor. In particular, the application of the simulation methods is more common.

Colour Interpolation of Tongue Image in Digital Tongue Image System Blocking Out External Light (디지털 설진 시스템의 색상 보정)

  • Kim, Ji-Hye;Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2012
  • Objectives The aim of this study is to propose an optimized tongue colour interpolation method to achieve accurate tongue image rendering. Methods We selected 60 colour chips in the chips of DIC color guide selector, and then divided randomly the colour chips into two groups. The colour chips of a group (Gr I) were used for finding the optimized colour correction factor of error and those of the other group (Gr II) were used for verifying the correction factor. We measured colour value of the Gr I colour chips with spectrophotometer, and took the colour chips image with a digital tongue image system (DTIS). We adjusted colour correction factor of error to equal the chip colour from each method. Through that process, we obtained the optimized colour correction factor. To verify the correction factor, we measured colour value of the Gr II colour chips with a spectrophotometer, and took the colour chips image with the DTIS in the two types of colour interpolation mode (auto white balance mode and optimized colour correction factor mode). And then we calculated the CIE-$L^*ab$ colour difference (${\Delta}E$) between colour values measured with the spectrophotometer and those from images taken with the DTIS. Results In auto white balance mode, The mean ${\Delta}E$ between colour values measured with the spectrophotometer and those from images taken with the DTIS was 13.95. On the other hand, in optimized colour correction factor mode, The mean ${\Delta}E$ was 9.55. The correction rate was over 30%. Conclusions In case of interpolating colour of images taken with the DTIS, we suggest that procedure to search the optimized colour correction factor of error should be done first.

Analytical determination of shear correction factor for Timoshenko beam model

  • Moghtaderi, Saeed H.;Faghidian, S. Ali;Shodja, Hossein M.
    • Steel and Composite Structures
    • /
    • v.29 no.4
    • /
    • pp.483-491
    • /
    • 2018
  • Timoshenko beam model is widely exploited in the literature to examine the mechanical behavior of stubby beam-like components. Timoshenko beam theory is well-known to require the shear correction factor in order to recognize the nonuniform shear distribution at a section. While a variety of shear correction factors are appeared in the literature so far, there is still no consensus on the most appropriate form of the shear correction factor. The Saint-Venant's flexure problem is first revisited in the frame work of the classical theory of elasticity and a highly accurate approximate closed-form solution is presented employing the extended Kantorovich method. The resulted approximate solution for the elasticity field is then employed to introduce two shear correction factors consistent with the Cowper's and energy approaches. The mathematical form of the proposed shear correction factors are then simplified and compared with the results available in the literature over an extended range of Poisson's and aspect ratios. The proposed shear correction factors do not exhibit implausible issue of negative values and do not result in numerical instabilities too. Based on the comprehensive discussion on the shear correction factors, a piecewise definition of shear correction factor is introduced for rectangular cross-sections having excellent agreement with the numerical results in the literature for both shallow and deep cross-sections.

Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT (PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰)

  • Kim, June;Kim, Jae-II;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted $^{18}F-FDG$ 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count -to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient($66{\pm}15age$) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is $8{\pm}0.5%$, correction factor of organs with CT number similar to soft tissue is $6{\pm}2%$ and correction factor of organs with low CT number(-100>) is $3{\pm}1%$. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn't happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -to-non attenuation correction image count ratio is one of the methods to reduce metal artifact affect.

  • PDF

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

Design of Zero Cross Detection Power Factor Correction IC (Zero Cross Detection Power Factor Correction IC 설계)

  • Seo, Kil-Soo;Kim, Hyoung-Woo;Kim, Ki-Hyun;Park, Hyeon-Il;Kim, Nam-Kyun;Park, Ju-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.519-520
    • /
    • 2008
  • In this paper, we design and implement the monolithic zero crossing detection power factor correction IC using a high voltage 30V BCD process. The ZCD PFC IC is designed for power applications, such as notebook, LCD monitor, etc. It includes power factor correction function and several protection circuit, regulator, high-voltage high current output drivers. And also, the designed IC has restart timer function which the output pulse is generated if the output signal of IC is not in a 200us. The simulation results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF