• 제목/요약/키워드: cryogenic

검색결과 1,149건 처리시간 0.025초

Investigation on the tensile properties of glass fiber reinforced polymer composite for its use as a structural component at cryogenic temperature

  • Shrabani Ghosh;Nathuram Chakrobarty;Swapan C. Sarkar
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.43-48
    • /
    • 2023
  • Polymer composites, especially glass fiber reinforced polymer (GFRP) are finding ever-increasing applications in areas such as superconductivity, space technology, cryogenic rocket engines, and cryogenic storage vessels. Various components made of polymer composites are much lighter than their metallic counterparts but have equivalent strength for ultra-low temperature applications. In this paper, we have investigated the tensile properties of an indigenously prepared unidirectional cylindrical hollow composite tube for its use as a neck of the cryogenic vessel. XRD and SEM of the tube are completed before cryogenic conditioning to ascertain the fiber and resin distribution in the matrix. The result shows that for composites, after 15, 30, 45, and 60 minutes of cryogenic conditioning at 77K in a liquid nitrogen bath, the strength and modulus increase significantly with the increase of strain rate and reach the optimum value for 45 minutes of conditioning. The results are encouraging as they will be helpful in assessing the suitability of GFRP in the structural design of epoxy-based components for cryogenic applications.

극저온 유체 화물창 방벽 내의 액체유동 및 기화 시뮬레이션 (LIQUID FLOW AND EVAPORATION SIMULATION OF CRYOGENIC FLUID IN THE WALL OF CRYOGENIC FLUID CARGO CONTAINMENT SYSTEM)

  • 박범진;이희범;이신형;배준홍;이경원;정왕조;안상준
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.9-18
    • /
    • 2009
  • The cargo containment system (CCS) for ships carrying cryogenic fluid consists of at least two levels of barriers and insulation layers. It is because, even though there is a small amount of leak through the primary barrier, the liquid tight secondary barrier blocks further leakage of the cryogenic fluid. However, once the secondary barrier is damaged, it is highly possible that the leaked cryogenic fluid flows through the flat joint made of glass wool and reaches the inner hull of the ship. The primary objective of the present study is to investigate the influence of the damage extent in the secondary barrier on the amount of leaked cryogenic fluid reaching the inner hull and the temperature distribution there. Simulation results using a computational fluid dynamics tool were compared with the experimental data for the leaked cryogenic fluid flow and evaporation in the secondary insulation layer. The experimental and computational results suggest that, unless there is a massive leak, the cryogenic fluid mostly evaporates in the insulation layer and does not reach the inner hull in the state of liquid.

극저온용 액중펌프 구조해석에 관한 연구 (A Study on the Structural Analysis of Cryogenic Submerged Pump)

  • 진도훈;이중섭
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.727-733
    • /
    • 2020
  • Recently, reciprocating cryogenic pumps are mainly developed for small-and-mid sized fuel supply systems. Centrifugal type pumps are not actively developed. Most cryogenic submerged pumps are imported. For transportation, cryogenic liquefied natural gas requires the liquid pump technology that can works in extreme evironments. In order to transport liquefied natural gas, it is necessary to apply pump technology. This is the fundamental research for developing the submerged pump technology applicable to the transportation and storage system equipment of cryogenic liquefied system. It tries to secure basic design materials through reverse-engineering in the cryogenic submerged pump development. Regarding materials, STS-304 and STS-431 which are stainless materials widely used in the cryogenic area are applied. Aluminum alloy is applied to impeller and upper manifolder and the pump rotates at the high speed of 6,000rpm.

고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성 (Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

극저온 볼 밀링을 통한 Ibuprofen 분말의 마이크로화 (Micronization of Ibuprofen by Cryogenic Ball Milling)

  • 조현갑;이경엽;백영남;박훈재;이상목
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.195-199
    • /
    • 2004
  • For the present study, the cryogenic ball milling process was applied to make Ibuprofen microsized. The cryogenic ball milling was performed at low temperature of about -18$0^{\circ}C$ for 6 hours. The particle size distribution was determined before and after the cryogenic process. X-ray diffraction (XRD) measurement was made to determine the effect of cryogenic process on the crystallinity of Ibuprofen. The results showed that the size of Ibuproffn was reduced about 10 times by the cryogenic process. The degree of crystallinity of Ibuproffn was slightly reduced by the cryogenic process.

극저온 LNG 배관냉각 특성에 대한 연구 (A Study on Cryogenic Line Chill Down Characteristics of LNG)

  • 변병창;김경중;정상권;김모세;이상윤;이근태;김동민
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.808-818
    • /
    • 2022
  • In this research paper, we investigated the cryogenic line chill down characteristics of liquefied natural gas (LNG). A numerical analysis model was established and verified so that it can calculate the precise cooling characteristics of cryogenic fluid for the stable and safe utilization especially such as LNG and liquid hydrogen. The numerical modeling was programmed by C++ as an one-dimensional homogeneous model. The thermohydraulic cooling process was simulated using mass, momentum, energy conservation equations and appropriate heat transfer correlations. In this process, the relevant heat transfer correlations for nuclear boiling, transition boiling, film boiling, and single-phase heat transfer that can predict the experimental results were implemented. To verify the numerical modeling, several cryogenic line chill down experiments using LNG were conducted at the Korea Institute of Machinery & Materials (KIMM) LNG and Cryogenic Technology Center.

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

Helium guard system design for HIAF iLinac cryogenic distribution system

  • Xianjin Wang;Shuping Chen;Wen Jun;Dajun Fan;Liming Zhu;Yanan Lib;Xiaofei Niu;Junhui Zhang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-10
    • /
    • 2023
  • 2 K superfluid helium cryogenic system is the crucial component of many large accelerators. When the cryogenic system is operating at 2K@3129Pa, many room-temperature parts are connected to superfluid helium via tubes. Air Leakage in these connections may lead to air contamination of the cryogenic system. Air contamination may cause equipment failure in cryogenic systems and, in extreme cases, render the entire accelerator system inoperable. Helium guard is a technique that guards against air contamination of these sub-atmospheric pressure connections in 2 K superfluid helium cryogenic system. This paper introduces a typical 2 K cryogenic distribution design for large accelerators, and make risk analysis of air contamination. Finally, the analysis of specific leakage points and detailed engineering design are presented, which may be used as a reference when designing of a 2 K superfluid helium cryogenic distribution system.

동결정액 포장방법이 돼지정액의 성상 및 번식성적에 미치는 영향 (Effect of Packing Materials of Frozen Boar Semen on Sperm Characteristics and Reproductive Performance)

  • 김인철;이장희;김현종;이성호;박창식
    • 한국가축번식학회지
    • /
    • 제26권2호
    • /
    • pp.119-124
    • /
    • 2002
  • 본 연구는 돼지에서 동결정액을 이용한 번식능력을 개선하기 위한 동결정액 포장재료의 효과를 구명하기 위하여 실시하였다. 본 시험에는 축산기술연구소 종축개량부 (충남, 성환)의 인공수정센터에서 사육중인 종모돈이 사용되었다. 기존의 돼지 동결정액 포장방법인 maxi-straw 동결정액 포장방법과 5$m\ell$빈 cryogenic-vial 및 aluminum-pack 포장방법을 비교한 결과 cryogenic-vial로 포장하여 액체질소 상단 15cm에서 동결한 후 52$^{\circ}C$ water bath에서 190초 융해한 방법이 기존의 maxi-straw 방법과 비슷한 결과를 나타내었다. Cyogenic-vial 포장방법의 동결-응해 방법을 설정하기 위하여 융해시간을 달리하여 시험한 결과 액체질소 상단 15cm에서 동결하고 52$^{\circ}C$에서 190초 간 융해하였을 때 정자운동성이 120초 및 150초 응해시 보다 우수하였다 (P<0.05). 그러나 정상첨체비율은 응해시간 간에 차이가 없었다. 52$^{\circ}C$에서 45초간 응해 한 maxi-straw 포장방법과 52$^{\circ}C$에서 190초 융해한 cryogenic-vial 포장방법간에 정액성상을 비교한 결과 총정자운동성과 정자의 빠르기는 maxi-straw가 우수하였다 (P<0.05). 그러나 직진성과 정상첨체비율은 두 포장방법간에 차이가 없었다. 동결정액 포장방법별 인공수정시 번식성적은 maxi-straw 동결정액이 cryogenic-vial 동결정 액보다 수태율, 분만율, 그리고 산자수가 높았으나 통계적 유의차는 인정되지 않았다. 이상의 결과를 종합해 보면 cryogenic-vial 포장 방법의 동결 및 음해방법을 좀 더 연구개발하면 기존의 maxi-straw포장방법을 대체하여 실용화 할 수 있을 것으로 사료된다.