• Title/Summary/Keyword: curvature calibration

Search Result 17, Processing Time 0.02 seconds

Comparison of linear and non-linear equation for the calibration of roxithromycin analysis using liquid chromatography/mass spectrometry

  • Lim, Jong-Hwan;Yun, Hyo-In
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • Linear and non-linear regressions were used to derive the calibration function for the measurement of roxithromycin plasma concentration. Their results were compared with weighted least squares regression by usual weight factors. In this paper the performance of a non-linear calibration equation with the capacity to account empirically for the curvature, y = ax$^{b}$ + c (b $\neq$ 1) is compared with the commonly used linear equation, y = ax + b, as well as the quadratic equation, y = ax$^{2}$+ bx + c. In the calibration curve (range of 0.01 to 10 ${\mu}g/mL$) of roxithromycin, both heteroscedasticity and nonlinearity were present therefore linear least squares regression methods could result in large errors in the determination of roxithromycin concentration. By the non-linear and weighted least squares regression, the accuracy of the analytical method was improved at the lower end of the calibration curve. This study suggests that the non-linear calibration equation should be considered when a curve is required to be fitted to low dose calibration data which exhibit slight curvature.

Measurement Errors of Non-contact Type Vibration Sensors Used for Precision Measurement of Shaft Vibration (정밀 축진동 측정에 사용되는 비접촉식 진동센서의 측정오차)

  • 전오성;김동혁;최병천
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.107-113
    • /
    • 1991
  • When non-contact type vibration probes are used for the precision measurement of shaft vibration, they can induce the measurement errors due to the shaft curvature since they have been calibrated for the flat plate. In this study the errors due to the shaft radius and the misalignment between the shaft and probe centerlines are analyzed, and an in-situ calibration tool, which can be conveniently used for calibration independent of the shaft curvature and material, is introduced.

  • PDF

Development of Automatic Measurement and Inspection System for ALC Block Using Camera (카메라를 이용한 ALC 블록의 치수계측 및 불량검사 자동화 시스템 개발)

  • 허경무;김성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.448-455
    • /
    • 2003
  • A system design technique of automatic thickness measurement and defect inspection system, which measures the thickness of the ALC(Autoclaved Lightweight Concrete) block and inspects the defect on a realtime basis is proposed. The image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by this system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. For the realization of the proposed algorithm, the preprocessing method that can be applied to overcome uneven lighting environment, an enhanced edge decision method using 8 edge-pairs with irregular and rough surface, the unit length decision method in uneven condition with rocking objects, and the curvature calibration method of camera using a constructed grid are developed. The experimental results, show that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

Calibration of Laser Scribe Force Using Finite Element Method (유한요소법을 이용한 레이저 화선력의 보정)

  • Chung, Chul-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1319-1324
    • /
    • 2007
  • Accurately controlling the shape of the read/write head structure is critical in the performance of a modem hard disk drive. The sliders investigated are composed of alumina and titanium carbide(AITiC) and act as an air bearing when passing over the disks. Controlling the curvature of the slider is of primary importance. A laser scribing system that produces curvature by inducing residual stress into the slider can be utilized. Predicting the curvature created by a pattern of scribes is of great importance to increase the control over the sliders' shape. The force system that produces stresses similar to the laser scribing is applied to the finite element analysis model. The curvatures created by the force system are calibrated to experimental measurements.

  • PDF

End Bearing Capacity of a Pile in Cohesionless Soils (사질토에 있어서 말뚝의 선단부 지지력)

  • 이명환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1988.06c
    • /
    • pp.71-123
    • /
    • 1988
  • The aim of this paper is to examine the end bearing capacity of a pile in cohesionless soils. The ode of failure of soil due to pile installation is assumed from experimental observation of actual soil deformation. A new solution is proposed complying with the assumed mode of failure by employing the theory of cavity expansion. The effect of curvature of failure envelope is studied in relation to tile proposed solution. The influence of a curved failure envelope becomes larger with increasing degree of curvature and the level of confining stress. This effect in some cases or reduce the end bearing capacity by tore the 80 percent compared with that given by a straight failure envelope. For practical application of tile proposed solution, the method of determining the average volume change in the plastic zone is re-evaluated. The proposed solution is confirmed by comparing the theoretical values with experimental results obtained from model pile tests in a calibration chamber. The comparison shows that the proposed solution provides a reasonable prediction of end bearing capacity for both weak and strong grained soils.

  • PDF

A Study on the Contact Error of Dial Gauge (DIAL GAUGE 측정자의 접촉오차에 관한 연구)

  • 강석수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.138-143
    • /
    • 2000
  • In order to maintain the faith and accuracy with precision of machinery, it is recently required the precise comprehension about approach which is appeared in the contact area between two bodies, because approach affects the static stiffness and dynamic characteristic of contact area. This study applied H. Hertz's circle contact area theory as much lower measuring force. It is measured approach influenced by various factors which were concerned with contact errors like material, form of two bodies, using calibration tester. As a result, the following conclusion can be obtained. 1) The approach appears greatly in order of carbon steel(SM20C), aluminum(A601-T6) and high density polyethylene(5305E) 2) The approach appears in order of concave, disc, convex form, in the ration of contact area size by the difference of curvature.

  • PDF

Improvement of Calibration Method of Thermochromic Liquid Crystal Reflecting Measurement Angle (측정각도를 고려한 액정교정기법의 개선)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Woo, Chang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.188-194
    • /
    • 2000
  • Thermochromic liquid crystal reflect a unique color at even temperature. Therefore, they have been successfully applied to non-intrusive heat transfer research. Hue capturing method is widely used in the quantitative measurement from the TLC image. However it is affected by several measurement conditions. The distances of camera and light source have little influence on the color, but the value of hue is seriously affected by the measurement angle. In this study, the hue capturing method is improved by considering the effect of measurement angle. This improved calibration method can diminish the misreading of temperature caused by curvature of test surface.

Linearity Analysis and Calibration of a Cable-Conduit Bend Sensor (케이블 컨듀잇 굽힘 센서의 선형 특성 분석 및 켈리브레이션)

  • Jeong, Useok;Cho, Kyu-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.1
    • /
    • pp.26-32
    • /
    • 2017
  • Previous shape sensors including bend sensors and optic fiber based sensors are widely used in various applications including goniometer and surgical robots. But theses sensors have large nonlinearity, limited in the range of sensing curvature, and sometimes are expensive. This study suggests a new concept of bend sensor using cable-conduit which consists of the outer sheath and the inner wire. The outer sheath is made of helical coil whose length of the central line changes as the sheath bends. This length change of the central line can be measured with the length change of the inner cable. The modeling and the experimental results show that the output signal of the proposed sensor is linearly related with the bend angle of the sheath with root mean square error of 5.3% of $450^{\circ}$ sensing range. Also the polynomial calibration of the sensor can decrease the root mean square error to 2.1% of the full sensing range.

Full-field Distortion Measurement of Virtual-reality Devices Using Camera Calibration and Probe Rotation (카메라 교정 및 측정부 회전을 이용한 가상현실 기기의 전역 왜곡 측정법)

  • Yang, Dong-Geun;Kang, Pilseong;Ghim, Young-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.237-242
    • /
    • 2019
  • A compact virtual-reality (VR) device with wider field of view provides users with a more realistic experience and comfortable fit, but VR lens distortion is inevitable, and the amount of distortion must be measured for correction. In this paper, we propose two different full-field distortion-measurement methods, considering the characteristics of the VR device. The first is the distortion-measurement method using multiple images based on camera calibration, which is a well-known technique for the correction of camera-lens distortion. The other is the distortion-measurement method by measuring lens distortion at multiple measurement points by rotating a camera. Our proposed methods are verified by measuring the lens distortion of Google Cardboard, as a representative sample of a commercial VR device, and comparing our measurement results to a simulation using the nominal values.

Development of Automatic ALC Block Measurement System Using Machine Vision (머신 비전을 이용한 ALC 블록 생산공정의 자동 측정 시스템 개발)

  • 엄주진;허경무
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.6
    • /
    • pp.494-500
    • /
    • 2004
  • This paper presents a machine vision system, which inspects the measurement of the ALC block on a real-time basis in the production process. The automatic measurement system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. Images obtained by this system was processed by an algorithm, specially designed for an enhanced measurement accuracy. For the realization of the proposed algorithm, a preprocessing method that can be applied to overcome uneven lighting environment, boundary decision method, unit length decision method in uneven condition with rocking objects, and a projection of region using pixel summation are developed. From our experimental results, we could find that the required measurement accuracy specification is sufficiently satisfied by using the proposed method.