• Title/Summary/Keyword: datum fixture

Search Result 5, Processing Time 0.02 seconds

Calibration off multiple-sensor measuring system for efficient visual inspection (형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구)

  • 김승만;손석배;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF

System Architecture and Datum Reference Frame for Computer Aided Fixture Planning System (치구계획의 자동화시스템 구성 및 데이텀 체계의 결정)

  • Cho, Kyu-Kab;Jeong, Yeong-Deug
    • IE interfaces
    • /
    • v.4 no.2
    • /
    • pp.1-12
    • /
    • 1991
  • This paper deals with the development of a computer aided fixture planning system that automatically selects set-ups, set-up sequence and fixture design for prismatic parts. This study presents the hierarchical data structure for feature-based part model and the preprocessing procedure for the proposed system. The preprocessing procedure generates tools such as DDR(Degree of Dimensional Relationship), AMV(Admissible Misalignment Value) and the datum reference frame of each feature according to the proposed decision table. The proposed system is called AFIX(Automated FIXture planning system) which is implemented by using C language on the workstation. A case study for a cavity plate is presented to show the performance of the AFM.

  • PDF

Setup Planning for Machining processes Using Expert System Approach (전문가 시스템 접근법을 이용한 기계가공용 셋업계획)

  • Jeong, Yeong-Deug
    • IE interfaces
    • /
    • v.6 no.1
    • /
    • pp.31-45
    • /
    • 1993
  • Setup planning for machining processes is a part of fixture planning which is also a part of process planning. A setup of a part is defined as a group of features which are machined while the part is fixtured in one single fixture. Setup planning includes a number of tasks such as the selection of setup, sequence of setups and datum frame for each setup. Setup planning is an important function in fixture planning which must be able to support and to clamp a workpiece to prevent deflections caused by machining and clamping loads. This paper presents setup planning system using expert system approach(SPES) for prismatic parts which can be machined on vertical milling machine. SPES consists of preprocessing module and main processing module. Preprocessing module executes the conversion of feature data to frame type data and the determination of setups, and main processing module executes the determination of datum frame of each setup and sequance of setups. Preprocessing module is coded by C language and main processing module is a rule-based expert system using EXSYS pro. The performance of SPES is evaluated through case studies and the results show successful work except for operation sequence of machining holes. This is due to the limited rules for machining holes.

  • PDF

Making Teeth Models using 3-aixs CNC Milling (3축 CNC 밀링을 이용한 치아 모형 제작 방법)

  • Choe, W.C.;Seo, U.J.;Baek, J.H.;Chung, Y.
    • Transactions of Materials Processing
    • /
    • v.23 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • The current study presents a simple setup method for making teeth models using a three-axis CNC milling machine. Physical teeth models can be made by several methods: casting, machining, and three-dimensional printing. Since the shape of a teeth model requires five-axis machining, the machining of a teeth model using a three-axis CNC milling machine requires careful setup operations. In this paper a simple datum shape is designed within the work piece of the teeth model. The datum shape is an n-sided prism with regular n-polygon ends and rectangular sides. In the present study a 12-sided prism is used, which easily makes 30 degree rotations for finish machining. The proposed setup approach does not require any special tools for making the teeth model using a three-axis CNC milling machine. A test was run and the results show that the proposed approach is useful for experimental makings with the limited facilities available.

Clinical Evaluation of Guided Bone Regeneration Using 3D-titanium Membrane and Advanced Platelet-Rich Fibrin on the Maxillary Anterior Area (상악 전치부 3D-티타늄 차폐막과 혈소판농축섬유소를 적용한 골유도재생술의 임상적 평가)

  • Lee, Na-Yeon;Goh, Mi-Seon;Jung, Yang-Hun;Lee, Jung-Jin;Seo, Jae-Min;Yun, Jeong-Ho
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.242-254
    • /
    • 2018
  • The aim of the current study was to evaluate the results of horizontal guided bone regeneration (GBR) with xenograf t (deproteinized bovine bone mineral, DBBM), allograf t (irradiated allogenic cancellous bone and marrow), titanium membrane, resorbable collagen membrane, and advanced platelet-rich fibrin (A-PRF) in the anterior maxilla. The titanium membrane was used in this study has a three-dimensional (3D) shape that can cover ridge defects. Case 1. A 32-year-old female patient presented with discomfort due to mobility and pus discharge on tooth #11. Three months after extracting tooth #11, diagnostic software (R2 GATE diagnostic software, Megagen, Daegu, Korea) was used to establish the treatment plan for implant placement. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$, Rocky Mountain Tissue Bank, Denver, USA), 3D-titanium membrane ($i-Gen^{(R)}$, Megagen, Daegu, Korea), resorbable collagen membrane (Collagen $membrane^{(R)}$, Genoss, Suwon, Korea), and A-PRF because there was approximately 4 mm labial dehiscence after implant placement. Five months after placing the implant, the second stage of implant surgery was performed, and healing abutment was connected after removal of the 3D-titanium membrane. Five months after the second stage of implant surgery was done, the final prosthesis was then delivered. Case 2. A 35-year-old female patient presented with discomfort due to pain and mobility of implant #21. Removal of implant #21 fixture was planned simultaneously with placement of the new implant fixture. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$), 3D-titanium membrane ($i-Gen^{(R)}$), resorbable collagen membrane (Ossix $plus^{(R)}$, Datum, Telrad, Israel), and A-PRF because there was approximately 7 mm labial dehiscence after implant placement. At the second stage of implant surgery six months after implant placement, healing abutment was connected after removing the 3D-titanium membrane. Nine months after the second stage of implant surgery was done, the final prosthesis was then delivered. In these two clinical cases, wound healing of the operation sites was uneventful. All implants were clinically stable without inflammation or additional bone loss, and there was no discomfort to the patient. With the non-resorbable titanium membrane, the ability of bone formation in the space was stably maintained in three dimensions, and A-PRF might influence soft tissue healing. This limited study suggests that aesthetic results can be achieved with GBR using 3D-titanium membrane and A-PRF in the anterior maxilla. However, long-term follow-up evaluation should be performed.