• Title/Summary/Keyword: demagnetization

Search Result 163, Processing Time 0.02 seconds

Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients

  • Kang, Dong-Hyeok;Kim, Hyung-Kyu;Park, Jun-Kyu;Hyun, Seung-Ho;Hur, Jin
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.48-56
    • /
    • 2016
  • This paper proposes a method for detecting irreversible demagnetization using the harmonic analysis of back electromotive force (BEMF) in interior permanent magnet-type brushless DC motors. First, demagnetization patterns, such as equality, inequality, and weighted demagnetizations, are defined and classified by considering the possibility of demagnetization resulting from motor operating characteristics. Second, an available diagnostic model for the harmonic analysis of BEMFs is defined according to pole-slot coefficients because the characteristics of BEMFs under demagnetization conditions are affected by the combination of poles and slots. Third, BEMFs and their harmonic components under normal and demagnetization conditions are analyzed through simulation and experiment to verify the proposed demagnetization detection technique.

Design of SPOKE Type BLDC Motor for Traction Application Considering Irreversible Demagnetization of Permanent Magnet

  • Hur Jin;Kang Gyu-Hong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.129-136
    • /
    • 2005
  • This paper presents a design strategy of SPOKE type BLDC motors considering an irreversible demagnetization of a permanent magnet (PM). So the irreversible demagnetization characteristic of the motor is analyzed by rotor structure. The instantaneous currents in either starting or lock rotor condition, which are calculated from the current dynamic analysis, are applied to the analysis of the irreversible demagnetization field by FEM. In irreversible demagnetization analysis by FEM, the variation of residual flux density in PM is analyzed using the non-linearity of magnetic core on B-H plan. The analysis results are compared to several rotor structures and used for optimize the rotor structure.

Demagnetization Diagnosis of Permanent Magnet Synchronous Motor Using Frequency Analysis at Standstill Condition

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.249-254
    • /
    • 2016
  • Recently, electric vehicles have got significant attention because it is more eco-friendly and efficient than internal combustion engine vehicles. Instead of an internal combustion engine, the electric vehicle has a motor for propulsion. The permanent magnet synchronous motor which has permanent magnet instead of field winding in the rotor has especially higher efficiency and power density than other types of motor. When the irreversible demagnetization is occurred, drivers are exposed to high risk of accident by the fault operation of motor. Therefore, the irreversible demagnetization of permanent magnet should be detected to reduce the risk of accident. In this study, the demagnetization diagnosis method based on the result of locked rotor test is proposed. Based on short measurement time, the proposed diagnosis method aims to detect the demagnetization fault when an electric vehicle is at a complete standstill. The proposed method is verified through the finite element analysis.

Effect of Magnetization Pattern on Partial Demagnetization of Rotary Electric Machines with Ferrite Magnets (페라이트 영구자석을 이용한 회전형 전기기기의 착자 형태에 따른 부분 감자의 영향)

  • Kim, Kwan-Ho;Park, Hyung-Il;You, Dae-Joon;Jang, Seok-Myeong;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1679-1685
    • /
    • 2015
  • This paper examines the effect of the magnetization pattern on the partial demagnetization of a permanent magnet (PM) machine that uses a ferrite magnet. Although the use of halbach-magnetized PM (HMPM) arrays in PM machines has been dramatically increasing because of their attractive features, the demagnetization characteristics of HMPM arrays have not yet been examined. In this study, two analyses of the demagnetization characteristics of HMPM arrays and parallel magnetized PMs (PMPMs) are performed, with the demagnetization characteristics being analyzed using a finite element method. According to our results, partial demagnetization occurred dramatically in the HMPM arrays. Thus, it is important to consider the vulnerability of HMPM arrays when designing PM machines.

A Rotor Design of a BLDC motor used for Reciprocating Compressor Considering Demagnetization (감자 특성을 고려한 왕복동형 압축기용 BLDC모터의 회전자 설계)

  • You, Yong-Min;Kim, Dae-Kyong;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.61-63
    • /
    • 2009
  • This paper design a rotor shape of a BLDC motor used for reciprocating compressor. Demagnetization analysis of a basic model is performed by 2D finite element method. This type improved demagnetization characteristics and showed good performance to resist partial demagnetization of ferrite magnet.

  • PDF

The Design of Flux Barrier for Improvement of Demagnetization Endurance in BLDC Motor

  • Kim, Cheol-Min;Kim, Dong-Yeong;Cho, Gyu-Won;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2181-2186
    • /
    • 2014
  • Generally, the motor inside vehicle is exposed to highly ambient temperature and large vibration according to repeatedly starting and stopping for very short time. So, in this paper, the rotor shape design was performed to improve demagnetization endurance by considering the starting current of the Brushless DC (BLDC) Motor through the Finite Element Method(FEM). As a result, the partial irreversible demagnetization was occurred by starting current at the end of Permanent Magnets of the basic model. To solve this problem, the flux barrier design was performed and the flux on the rotor core was limited. Accordingly, demagnetization endurance and operating characteristics were improved.

Improvement of Demagnetization by Rotor Structure of IPMSM with Dy-free Rare-Earth Magnet

  • Imamura, Keigo;Sanada, Masayuki;Morimoto, Shigeo;Inoue, Yukinori
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.141-147
    • /
    • 2013
  • Permanent magnet (PM) motors that employ rare-earth magnets containing dysprosium (Dy) are used in electric and hybrid electric vehicles. However, it is desirable to reduce the amount of Dy used since it is expensive. This study investigates the rotor structure of a PM synchronous motor with a Dy-free rare-earth magnet. Flux barrier shapes and PM thicknesses that enhance the irreversible demagnetization are investigated. In addition, a rotor structure that improves the irreversible demagnetization is proposed. We demonstrate that the proposed rotor structure without Dy improves the irreversible demagnetization.

Demagnetization Fault Diagnosis in IPMSM Using Linear Interpolation (선형보간법을 이용한 매립형 영구자석 동기모터의 감자고장진단)

  • Jeong, Hyeyun;Moon, Seokbae;Lee, Hojin;Kim, Sang Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.568-574
    • /
    • 2017
  • This paper proposes a demagnetization fault diagnosis method for interior permanent magnet synchronous motors(IPMSMs). In particular, a demagnetization fault is one of the most frequent electrical faults in IPMSMs. This paper proposes an estimation method for permanent magnet flux. The method is based on linear interpolation. The effectiveness of the proposed method for diagnose demagnetization faults is verified through various operating conditions by finite element simulation.

The Rotor Barrier Design of the BLDC Motor Consider that Irreversible Demagnetization of Permanent Magnets (영구자석의 불가역 감자 현상을 고려한 BLDC 전동기의 회전자 자속 장벽 설계)

  • Kim, Cheol-Min;Cho, Gyu-Won;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.48-53
    • /
    • 2014
  • Generally, the usage motor in the vehicle is exposed to highly ambient temperature and large vibration according to repeatedly starting and stopping during very short time. So, in this paper, the rotor shape design was performed to improve demagnetization endurance by considering starting current of Brushless DC Motor (BLDCM) through Finite Element Method(FEM). As a result, the end of Permanent Magnet (PM) in the basic model was occurring a partial irreversible demagnetization by starting current. To solve this problem, the installing flux barrier was limited to flux line on the core. Accordingly, demagnetization endurance and operating characteristics were improved.

Dynamic Analysis Algorithm of Irreversible Demagnetization of IPM-type Brushless DC Motor by Stator Turn Fault (고정자 절연파괴 고장에 의한 매입형 영구자석 BLDC 모터의 불가역 감자에 대한 동적해석 알고리즘)

  • Lee, Yoon-Seok;Kim, Kyung-Tae;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1661-1667
    • /
    • 2013
  • This paper studies the dynamic irreversible demagnetization characteristics of an interior permanent magnet (PM) brushless DC motor with a stator turn fault. A new algorithm, which is a finite element method (FEM) combined with a line voltage equation of the motor, is developed to analyze irreversible demagnetization under dynamic and transient states and considers a stator turn fault. The input current, circulating current, magnetic distribution characteristics, and operating property of the PM, including the irreversible demagnetization in the fault state, are analyzed using this algorithm by considering the magnetic saturation effect. The feasibility of the proposed method confirmed from the analysis results is verified via an experiment. Through this fault analysis, we can accurately check the fault phenomena of a PM motor against the demagnetization fault for fault prevention.