• 제목/요약/키워드: dew point

검색결과 192건 처리시간 0.025초

기상자료를 활용한 도로표지 결로의 지역별 발생가능성 분석 (Regional Analysis of Dew Possibility in Road Sign Using Meteorological Data)

  • 오세창;김정민;최기주;안영미
    • 한국도로학회논문집
    • /
    • 제15권5호
    • /
    • pp.195-202
    • /
    • 2013
  • PURPOSES : This study analyzed the regional dew possibility in road sign using meteorological data. METHODS : Four years of meteorological data such as temperature, humidity, dew point, wind velocity were collected and analyzed. As a result of literature review, dew was frequent in large diurnal range, high humidity and weak wind. So, dew possibility was analyzed by (temperature-dew point ${\leq}1^{\circ}C$ and wind velocity ${\leq}$ 1.5m/s). RESULTS : The possibility was analyzed for each meteorological observation point and the point of Suncheon and Bonghwa were selected as the most likely points of dew in road sign. The area of East Coast, Kyungbuk and Kyungnam were relatively low potential. CONCLUSIONS : Alternative with high effect of preventing dew should be selected in high possibility dew area despite of low economics.

천연가스의 탄화수소 및 물 이슬점 계산 (Calculation of the Hydrocarbon and Water Dew points of Natural Gas)

  • 하영철;이성민;허재영;이강진;이승준
    • Korean Chemical Engineering Research
    • /
    • 제47권5호
    • /
    • pp.565-571
    • /
    • 2009
  • 본 연구에서는 천연가스의 탄화수소 이슬점과 물 이슬점을 계산하고자 하였다. 이를 위해 임계압력 근방까지 탄화수소 이슬점이 계산되도록 발산 방지 로직을 고안하였고 물 이슬점의 대해서는, 상용프로그램과 달리 탄화수소 이슬점 이하에서도 이슬점이 계산될 수 있도록 로직을 개발하였다. 그리고 계산결과는 국외 상용프로그램 및 ISO와 비교하였으며 차이는 없는 것으로 나타났다.

산화 알루미늄 및 냉각거울 노점계의 온도 의존성에 관한 연구 (The Effect of Temperature on Aluminum Oxide and Chilled Mirror Dew-point Hygrometers)

  • 김종철;최병일;우상봉;김용규;이상욱
    • 센서학회지
    • /
    • 제26권1호
    • /
    • pp.50-55
    • /
    • 2017
  • The measurement of absolute humidity of gases is essential in many industries. The effect of temperature on aluminum oxide and chilled mirror dew-point hygrometers is investigated. The temperature of laboratory, pipe line, and sensor is varied and the dew point is measured by two different aluminum oxide hygrometers. In all cases, the dew point of hygrometers is increased as the temperature is elevated. The reason behind this observation is due to desorption of water from the inside of pipe line and/or sensor surroundings at elevated temperature that result in the increase of the absolute humidity. Moreover, the sensor itself shows a certain degree of temperature dependency in sensing the humidity especially at low temperature. It is also studied that chilled mirror dew-point hygrometer may indicate a higher dew point than the reference at high temperature because the cooling capability of mirror is decreased at high temperature. Our study will provide evidences in the incorporation of the temperature effect as uncertainty factors in the standard calibration procedure for dew point hygrometers.

SOx노점의 전기적 측정 (Electrical Measurement of SOx Dew Point)

  • 전영남;용기중;채지우
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.600-610
    • /
    • 1995
  • When combustion gas is cooled down below the dew point of sulfuric acid vapor in the heat recovery systems, condensation occurs. Since the condensed sulfuric acid solution causes low-temperature corrosion in materials, it is important to measure the SOx dew point by electric measurement. In this study, two kinds of probes having electric gaps of 1mm or 2mm were used. and experiments were carried out by the parameters of sulfuric acid vapor and water vapor concentration. The changes of electric current caused by sulfuric acid condensed on the surface of probe according to the cooling rate and the probe head surface temperature were sudied. The opimum cooling rate was decreased with the increasing of water vaper concentration regardless of sulfuric acid concentration. The sensitivity of electric current is improved for the narrower gap(1mm) of ring electrodes, but it rarely affects the SOx dew point measuring of different probes according to the change of cooling rate.

  • PDF

발전소 공기예열기 소재의 배기가스 농도 및 온도에 따른 내식성 및 노점 분석 (Analysis of Corrosion Resistance and Dew Point with Exhaust Gas Concentration and Temperature for Air Preheater Materials in Power Plants)

  • 이승준
    • Corrosion Science and Technology
    • /
    • 제22권5호
    • /
    • pp.351-358
    • /
    • 2023
  • Although many thermal power plants use heat recovery systems, high exhaust gas temperatures are maintained due to corrosion at dew points and ash deposits caused by condensate formation. The dew point of exhaust gas is primarily determined by the concentration of SO3 and steam, and various experiments and calculation equations have been employed to estimate it. However, these methods are known to be less suitable for exhaust gases with low SO3 concentrations. Therefore, in this study, since the temperature of the exhaust gas is expected to decrease due to the low-load operation of the coal-fired power plant, sulfuric acid condensation and low-temperature corrosion are anticipated. We aimed to conduct a quantitative evaluation to propose ways to prevent damage by limiting operating conditions and improving facilities. The experimental results showed that the corrosion rate increased linearly with rising temperatures at a certain sulfuric acid concentration. Furthermore, variations in sulfuric acid concentrations generated during the current power plant operation process did not significantly affect the dew point, and the dew point of sulfuric acid under these conditions was observed to be between 120 - 130 ℃.

수정미소저울 노점센서 제작 및 반응특성 연구 (Development of QCM dew point sensor and its sensing characteristics study)

  • 권수용;김종철;최병일
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.269-276
    • /
    • 2006
  • This paper represents development of quartz crystal microbalance (QCM) and usage as a dew point sensor. The temperature of a quartz resonator was controlled precisely from $20^{\circ}C$ to $-30^{\circ}C$ with the ramping rate of $0.1^{\circ}C/s$ by using a custom-made crystal holder housing the quartz resonator associated with a thermoelectric cooler (Peltier cooler), which results in the working range from $15.2^{\circ}C$ to $-24.0^{\circ}C$ based on an accurate holder temperature compensation and temperature effect compensation process. The developed QCM dew point sensor and analysis techniques show very good sensing characteristics at measurement of moist air with the relative humidity from 10 %R.H. to 90 %R.H. generated by a divided-type humidity generator and the dew point temperatures were determined with an accuracy of less than ${\pm}0.18^{\circ}C$, which also showed good agreement with reference values in their error range.

발전소 절탄기 튜브의 배기가스 온도와 황산 농도에 따른 노점 및 내식성 분석 (Analysis of dew point and corrosion resistance for power plant economizer tube with exhaust gas temperature and sulfuric acid concentration)

  • 최재훈;이승준
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.433-440
    • /
    • 2022
  • Environmental pollution caused by power plant exhaust gas is highlighted and eco-friendly regulations are being strengthened. However, due to the abundant reserves and low prices of coal, still the most used for power generation in the world. Therefore, flexible operation of coal-fired power plants to reduce emissions has become an inevitable option. However, lowering the output increases the possibility of acid dew point corrosion as the exhaust gas temperature decreases. The dew point corrosion occurs when condensable gases such as SO3, HCl, NO2 and H2O cools below the saturation temperature. SO3 is already well known to cause severe low- temperature corrosion in coal-fired power plants. Therefore, this study aims to prevent damage that may occur during operation by analyzing the dew point and corrosion resistance with exhaust gas temperature and sulfuric acid concentration of the power plant economizer tube.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

천연가스의 탄화수소 이슬점 측정방법 비교 연구 (A Study on the Comparison of Methods for the Measurement of Hydrocarbon Dew Point of Natural Gas)

  • 이강진;하영철;허재영;우진춘;김용두;배현길
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.496-502
    • /
    • 2015
  • 탄화수소 이슬점은 천연가스 응축형태를 특성화하는 가장 일반적이고 자주 이용되는 물성으로 가스 품질 사양의 중요한 항목이다. 탄화수소 이슬점은 미량의 고탄화수소 성분에도 매우 민감한 것으로 알려져 있어, 특히 천연가스를 공급하는 가스 회사 입장에서는 기존 합의된 가스 사양을 만족하는 것 뿐만 아니라, 발생된 탄화수소 응축물에 의해 운영설비 및 안전에 심각한 문제를 일으킬 수 있으므로 탄화수소 이슬점을 정확하게 구하는 절차를 확립하는 것이 중요하다. 본 연구에서는 실제 현장조건 하에서 탄화수소 이슬점을 측정하기 위해 냉각 거울 방식의 이슬점 측정기를 설치, 운영하였으며, 측정된 이슬점 온도는 가스분석기에 의해 분석된 조성 및 천연가스 산업계에서 인정된 상태방정식을 이용하여 계산된 이슬점 온도와 비교하였다. 시험 결과 탄화수소 이슬점 측정기는 매우 안정되게 이슬점을 측정하였으며, 이슬점 측정기를 검증하기 위한 시험 가스로는 순수 프로판 가스가 적정하였다. 제조 표준가스 및 실제가스의 측정결과를 가스분석기에 의한 간접 측정 결과와 비교시에도 적정한 범위 내에서 일치하는 것을 확인하였다.

이슬 결로점 기반 수배전반 결로 방지 장치 제작 (System Implementation for Dew Condensation Prevention of Distributing Boards based on the Dew Point)

  • 김태명;지석근;김영완
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.645-650
    • /
    • 2018
  • 본 논문에서는 옥내 외에 설치 운영되는 수배전반의 결로 현상을 방지하는 IT 기반 자동 온습도 제어기를 설계하고 제작하였다. 이슬 결로점 온도가 실내공간의 습도와 온도로부터 산출되고, 이슬 결로점 온도와 결로 부위의 온도를 비교하여 수배전반의 결로 현상을 방지할 수 있는 시설이 순차적으로 제어 동작되도록 구현하였다. 아울러 원격지의 수배전반의 결로 기반 제어기 동작 상태를 모니터링 할 수 있는 원격 모니터링 장치를 LoRa 무선통신 방식을 사용하여 구현하였다. 제어기와 원격 모니터링 장치를 설치 운영하여 전송되는 데이터의 정확성과 결로 기반 제어기 동작상태의 안정성을 확인하였다. 본 제어 장치는 수배전반 이외에 결로가 발생되는 장비에 설치되어 결로를 방지할 수 있는 장치로 용이하게 활용될 수 있다.