• Title/Summary/Keyword: direct bus lines

Search Result 10, Processing Time 0.018 seconds

A Study of Origin and Destination Decision for a Direct Bus Line in a City with Transit Mobility and Potential Demand (대중교통 이동성과 잠재수요를 이용한 도시 내 지역 간 직결노선버스 기종점 선정에 관한 연구)

  • Chang, Kyung Uk;Kim, Hwang Bae;Park, Hong Sik;Park, Seon Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.547-553
    • /
    • 2011
  • This study has redefined the concepts of mobility indexes and potential demand, standards to evaluate areas with the worst public transportation system and applied the relevant indexes to select the areas with the worst public transportation mobility and present a method to set direct public transportation lines between these regions. The mobility indexes and indexes to evaluate potential demand were applied to select the regions with the worst public transportation systems in four metropolitan cities and case studies were carried out on direct lines provided between these regions. The analysis results showed that in public transportation mobility blind spots, public transportation takes much longer than driving an automobile or public transportation services are not provided. In addition, the analysis showed that a direct lines system to solve such worst off regions should be built to have public transportation take as much time as driving an automobile by establishing lines for automobiles only, minimize time lost from hopping up and down a bus and maximize connections.

A Congestion Management Approach Using Probabilistic Power Flow Considering Direct Electricity Purchase

  • Wang, Xu;Jiang, Chuan-Wen
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.820-831
    • /
    • 2015
  • In a deregulated electricity market, congestion of the transmission lines is a major problem the independent system operator (ISO) would face. Rescheduling of generators is one of the most practiced techniques to alleviate the congestion. However, not all generators in the system operate deterministically and independently, especially wind power generators (WTGs). Therefore, a novel optimal rescheduling model for congestion management that accounts for the uncertain and correlated power sources and loads is proposed. A probabilistic power flow (PPF) model based on 2m+1 point estimate method (PEM) is used to simulate the performance of uncertain and correlated input random variables. In addition, the impact of direct electricity purchase contracts on the congestion management has also been studied. This paper uses artificial bee colony (ABC) algorithm to solve the complex optimization problem. The proposed algorithm is tested on modified IEEE 30-bus system and IEEE 57-bus system to demonstrate the impacts of the uncertainties and correlations of the input random variables and the direct electricity purchase contracts on the congestion management. Both pool and nodal pricing model are also discussed.

Contingency Severity Ranking Using Direct Method in Power Systems (전력계통에 있어서 직접법을 활용한 상정사고 위험순위 결정)

  • Lee, Sang-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.67-72
    • /
    • 2005
  • This paper presents a method to select contingency ranking considering voltage security problems in power systems. Direct method which needs not the detailed knowledge of the post contingency voltage at each bus is used. Based on system operator's experience and knowledge, the membership functions for the MVAR mismatch and allowable voltage violation are justified describing linguistic representation with heuristic rules. Rule base is used for the computation of severity index for each contingency by fuzzy inference. Contingency ranking harmful to the system is formed by the index for security evaluation. Compared with 1P-1Q iteration, this algorithm using direct method and fuzzy inference shows higher computation speed and almost the same accuracy. The proposed method is applied to model system and KEPCO pratical system which consists of 311 buses and 609 lines to show its effectiveness.

A study on Voltage Stability Analysis by the Lyapunov Direct Method in 2-bus Systems (Lyapunov 직접법에 의한 2모선 개통의 전압안정도 해석)

  • Moon, Young-Hyun;Lee, Tae-Shik;Kim, Baik;Lee, Eung-Hyuk;Park, Neung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.106-108
    • /
    • 1993
  • This paper gives derivations of voltage collapse conditions by using the Lyapunov function, which yields the exactly same results with the sensitivity analysis approach. On the other hand, the voltage collapse phenomenon is interpreted in the physical sense, and causes of the static voltage unstability and the dynamic voltage unstability are analyzed with the use of proposed Lyapunov function. In addition a new method is developed to calculate the power capacity limit of transmission lines with respect to voltage stability. This paper shows that it is able to analyze the voltage collapse with the Lyapunov direct method in the simple 2-bus system and proposes that the method works well by observing the variation of Lyapunov function as the load is increased in the system.

  • PDF

Load Shedding Algorithm Using Linear Programming for Congestion Problems by a Major Contingency

  • Shin Ho-Sung;Song Kyung-Bin
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.371-377
    • /
    • 2005
  • Congestion problems of transmission lines are very important research issues in power system operations. Load curtailment is one of the ways to solve congestion problems by a major contingency. A systematic and effective mechanism for load shedding has been developed by investigating congestion distribution factors and the direct load control program. In this paper, a load shedding algorithm using linear programming for congestion problems by a major contingency is presented. In order to show the effectiveness of the proposed algorithm, it has been tested on the 6-bus sample system and the power system of Korea, and their results are presented.

A Study on Power System Voltage Stability Analysis by the Direct Lyapunov Function (Luapunov 직접법에 의한 전력계통 전압안정도 해석)

  • 문영현;박능수;이태식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.693-702
    • /
    • 1994
  • This paper deals with direct voltage stability analysis using a power system energy function. The structure preserved energy function is proposed as an energy function for voltage stability analysis. With the use of the proposed energy function voltage collapse conditions are derived, which yields the exactly same results with the Jacobian matrix approach. The voltage collapse phenomenon is analyzed by several methods, which shows that all of the methods produce the same voltage condition. This study also investigates the voltage collapse dynamics by using the proposed energy function. As a result, it has been found that the voltage collapse can be classified into two categories: static and dynamic instablilties which have quite different behaviors. In addition a new method is presented to calculate the power capacity limit of transmission lines with respect to voltage stability. The proposed method is tested for a 2-bus sample system, which shows the characteristics of voltage collapse phenomenon via the energy function.

Probabilistic Reliability Based HVDC Expansion Planning of Power System Including Wind Turbine Generators (풍력발전기를 포함하는 전력계통에서의 신뢰도 기반 HVDC 확충계획)

  • Oh, Ungjin;Lee, Yeonchan;Choi, Jaeseok;Yoon, Yongbeum;Kim, Chan-Ki;Lim, Jintaek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • New methodology for probabilistic reliability based grid expansion planning of HVDC in power system including Wind Turbine Generators(WTG) is developed in this paper. This problem is focused on scenario based optimal selection technique to decide best connection bus of new transmission lines of HVDC in view point of adequacy reliability in power system including WTG. This requires two kinds of modeling and simulation for reliability evaluation. One is how is reliability evaluation model and simulation of WTG. Another is to develop a failure model of HVDC. First, reliability evaluation of power system including WTG needs multi-state simulation methodology because of intermittent characteristics of wind speed and nonlinear generation curve of WTG. Reliability methodology of power system including WTG has already been developed with considering multi-state simulation over the years in the world. The multi-state model already developed by authors is used for WTG reliability simulation in this study. Second, the power system including HVDC includes AC/DC converter and DC/AC inverter substation. The substation is composed of a lot of thyristor devices, in which devices have possibility of failure occurrence in potential. Failure model of AC/DC converter and DC/AC inverter substation in order to simulate HVDC reliability is newly proposed in this paper. Furthermore, this problem should be formulated in hierarchical level II(HLII) reliability evaluation because of best bus choice problem for connecting new HVDC and transmission lines consideration. HLII reliability simulation technique is not simple but difficult and complex. CmRel program, which is adequacy reliability evaluation program developed by authors, is extended and developed for this study. Using proposed method, new HVDC connected bus point is able to be decided at best reliability level successfully. Methodology proposed in this paper is applied to small sized model power system.

A Study on the Automation of MVDC System-Linked Digital Substation (MVDC 시스템연계 디지털변전소 자동화 연구)

  • Jang, Soon Ho;Koo, Ja Ik;Mun, Cho Rong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.199-204
    • /
    • 2021
  • Digital substation refers to a substation that digitizes functions and communication methods of power facilities such as monitoring, measuring, control, protection, and operation based on IEC 61850, an international standard for the purpose of intelligent power grids. Based on the intelligent operating system, efficient monitoring and control of power facilities is possible, and automatic recovery function and remote control are possible in the event of an accident, enabling rapid power failure recovery. With the development of digital technology and the expansion of the introduction of eco-friendly renewable energy and electric vehicles, the spread of direct current distribution systems is expected to expand. MVDC is a system that utilizes direct current lines with voltage levels and transmission capacities between HVDCs applied to conventional transmission systems and LVDCs from consumers. Converting existing lines in substations, where most power equipment is alternating current centric, to direct current lines will reduce transmission losses and ensure greater current capacity. The process bus of a digital substation is a communication network consisting of communication equipment such as Ethernet switches that connect installed devices between bay level and process level. For MVDC linkage to existing digital substations, the process level was divided into two buses: AC and DC, and a system that can be comprehensively managed in conjunction with diagnostic IEDs as well as surveillance and control was proposed.

Direct Patterning Technology of Indium Tin Oxide Layer using Nd:$YVO_4$ Laser Beam (Nd:$YVO_4$ 레이저 빔을 이용한 인듐 주석 산화물 직접 묘화 기술)

  • Kim, Kwang-Ho;Kwon, Sang-Jik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.8-12
    • /
    • 2008
  • For the reduction of fabrication cost and process time of AC plasma display panel (PDP), indium tin oxide (ITO) layer was patterned as bus electrode using Nd:$YVO_4$ laser. In comparison with the chemically wet etched ITO patterns, laser ablated ITO patterns showed the formation of shoulders and ripple-like structures at the edge of the ITO lines. For the reduction of shoulders and ripple-like structures, pulse repetition rate and scan velocity of laser was changed. In addition, we analyzed a discharge characteristic of PDP test panel to observe how the shoulders and ripple-like structures influence on the PDP. Based on experimental results, the pattern etched at the 500 mm/s and 40 kHz was better than any other condition. From this experiment we could see the possibility of the laser direct patterning for the application to the patterning of ITO in AC-PDP.

KTX Impact on the Inter-Regional Transportation System (고속철도 개통후 지역간 교통체계의 변화)

  • Lee, Jin-Seon;Kim, Gyeong-Tae
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.2
    • /
    • pp.75-82
    • /
    • 2005
  • To relieve congestion in the current system of intercity transportation, the Korea decided in 1990 to construct a high-speed railroad between Seoul and Busan and it is now in operation. This new mode of transportation significantly cut travel time between major cities and a trip from Seoul to the southeastern port of Busan. Since the KTX opening, average daily passenger numbers on both the Gyeongbu and Honam lines have increased about 1.3 fold over 2003 levels. As of December 2004, the KTX trains are carrying about 81,000 people a day. On KTX routes, the daily number of airline passengers dropped. Express long-distance bus traffic also dropped by 20% to 30%, while that on short-distance routes (100km or less) increased by about 20%. These figures clearly indicate that the Korean transportation network is becoming railroad-centric. However, the number of KTX passengers is fewer than anticipated possibly due to the Korean economic downturn and the operation of the KTX will leave many existing Saemaul and Mugunghwa train sets idle, which will be put into operation for areas, not covered by the KTX. When all the existing major lines have been electrified, more high-speed rail services will be phased in using direct connections to maximize operational efficiency. And also, the dual management by KTX and conventional rail will be regarded as the promotion of the benefit of the public.