• Title/Summary/Keyword: e-Actuator

Search Result 176, Processing Time 0.039 seconds

Realtime e-Actuator Fault Detection using Online Parameter Identification Method (온라인 식별 및 매개변수 추정을 이용한 실시간 e-Actuator 오류 검출)

  • Park, Jun-Gi;Kim, Tae-Ho;Lee, Heung-Sik;Park, Chansik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.376-382
    • /
    • 2014
  • E-Actuator is an essential part of an eVGT, it receives the command from the main ECU and controls the vane. An e-Actuator failure can cause an abrupt change in engine output and it may induce an accident. Therefore, it is required to detect anomalies in the e-Actuator in real time to prevent accidents. In this paper, an e-Actuator fault detection method using on-line parameter identification is proposed. To implement on-line fault detection algorithm, many constraints are considered. The test input and sampling rate are selected considering the constraints. And new recursive system identification algorithm is proposed which reduces the memory and MCU power dramatically. The relationship between the identified parameters and real elements such as gears, spring and motor are derived. The fault detection method using the relationship is proposed. The experiments with the real broken gears show the effectiveness of the proposed algorithm. It is expected that the real time fault detection is possible and it can improve the safety of eVGT system.

Microgripper driven by E-T(Electro-Thermal) actuator (E-T(Electro-Thermal) 액츄에이터를 이용한 microgripper)

  • Park, Ho-Joon;Lee, Hyun-Ki;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3325-3327
    • /
    • 1999
  • A microgripper driven by E-T (electro-thermal) actuators has been designed and fabricated by surface micromachining. This microgripper consists of two E-T actuators. Each actuator has two arms with different widths joined at the end to form a 'U' shape. The wider 'cold' arm has a narrow flexure at the end (anchor or electrode side) for easy bending, This actuator can be fabricated with only two masks - one for the sacrificial layer and the other for the poly-Si structure layer. An E-T actuator bends its arm due to unequal thermal expansion between the 'cold' arm and the 'hot' arm, This actuator tip moves laterally in an arcing motion towards the cold arm side when the structure is unevenly heated by the applied current. Therefore each microgripper is actuated inwards and can hold a micro object. The fabricated E-T actuator was operated in the range of $2{\sim}12V$ and $1{\sim}5mA$. and maximum tip displacement was $13.6{\mu}m$. This device may become useful in many applications because an E-T actuator can be designed and fabricated easily, and obtain large displacement.

  • PDF

Analysis for Dynamic Characteristics of Magnetic Actuator According to Input Current (입력전류에 따른 Magnetic Actuator의 동작특성 해석)

  • Oh, Y.H.;Song, K.D.;Kim, K.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.813-815
    • /
    • 2003
  • In this study, two magnetic actuator models are chosen to interpret dynamic characteristics. First model has no permanent magnet, on the contrary second has magnet that hold plunger to keep steady state. Both models are dynamically analyzed according to input current, and also compared with spending time and magnetic force at that moving is finished.

  • PDF

Development of a pneumatic actuator for Micro-Positioning control (미세 변위제어를 위한 공압 액추에이터 개발)

  • 손영선;이동주;이종옥
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.429-434
    • /
    • 2002
  • In order to improve the accuracy in the field of simiconductor and LCD research equipment, the demand of XYZ stage which is possible to control X axis, Y axis and Z axis has been increased steadly in place of the existing XY stage which is only practicable to X & Y axis positioning control. This paper presents a new pneumatic actuator for Micro-positioning control in the XYZ stage. Air pressure in a pneumatic actuator is controlled by the E/P Regulator. The control range of pneumatic actuator is about 100 micro-meters and it's construction concept is easy to apply a practical state

  • PDF

Design of Large Displacement Piezoelectric Bimorphs with Finite Element Method (유한 요소법을 이용한 대변위 압전 Bimorph 설계)

  • 임종인;노용래;김선욱
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.4
    • /
    • pp.337-342
    • /
    • 1997
  • This paper describes the design and evaluation of new type piezoelectric bimorph actuator that shows much large mechanical response than those conventional types. The bimorph actuator has modified structure combined with the multilayer actuator(MLA) and the composite multilayer actuator called "Moonie". The design and performancean alysis of bimorph actuator are carried out with Finite Element Method (FEM). Theoretical calculation results show that the generating force and displacement of Moonie-modified bimorph actuator can be improved by about 130% and 150%, respectively. The overshooting and ringing phenomena of the bimorph can be effectively restrained by the pseudo step electric field having a rising time coincied with a period of the fundamental vibration mode of the bimorph.e bimorph.

  • PDF

Relationship Between CFRP Ply Orientation and Performance Stroke in Piezoelectric Zirconate Titanate Composite Actuator(PZTCA) of Artificial Muscle (인공근육에 적용되는 압전복합재료 작동기의 탄소섬유 배향각과 작동변위의 관계)

  • Kim Cheol-Woong;Lee Sung-Hyuk;Yoon Kwang-Joon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.641-644
    • /
    • 2005
  • The aim of this research is to evaluate the relationship between the total effective moment $(M^E)$ and Bemoulli-Euler bending moment (M) when the ply orientations of UD CFRP in Piezoelectric Zirconate Titanate Composite Actuator (PZTCA) are changed. The obtained results as follows. Firstly, as the performance test results by the CFRP ply orientation, the performance of [0] and [90] were stable. However, while the performance of [+45] was suddenly decreased after 5 hours. Secondly, the change of $M^E$ by the CFRP ply orientation was evaluated. As the CFRP ply orientation was increased from [0] to [+60], the $M^E$ were gradually decreased. However, they became a little bit increased from [+60] to [90]. Finally, after the change of M by the CFRP ply orientation was evaluated, it was found that $M^E=2.2M$ was valid for just [0] and that there was a relationship between $M^E$ and M according to the ply orientation.

  • PDF

Numerical Study of 3D Unsteady Flow in a Blood Sac of TPLS: Effect of Actuator Speed (TPLS 혈액주머니 내의 3차원 비정상유동에 대한 수치해석 연구: 액추에이터 속도의 영향)

  • Jung G. S.;Seong H. C.;Park M. S.;Ko H. J.;Shim E. B.;Min B. G.;Park C. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.206-211
    • /
    • 2003
  • This paper reports the numerical results for blood flow of the sac squeezed by moving actuator in the TPLS(Twin Pulse Life Support System). Blood flow in the sac is assumed to be 3-dimensional unsteady newtonian fluid. where the blood flow interacts with the sac, which is activated by the moving actuator. The flow field is simulated numerically by using the FEM code, ADINA. It is well known that hemolysis is closely related to shear stress acted on blood flow. According to this fact, we simulate four models with different speed for moving actuator and examine the distribution of shear stress for each model. Numerical results show that maximum shear stress is strongly dependent on the actuator speed.

  • PDF

Vibration Analysis of HDD Actuator with Equivalent Finite Element Model of VCM Coil

  • Kim, Dong-Woohn;Lee, Jin-Koo;Park, No-Cheol;Park, Young-Pil
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.679-690
    • /
    • 2003
  • As the rate of increase in areal density of the HDD has accelerated, dynamic characteristics of the HDD actuator need to be improved with respect to the performance of the tracking servo and shock transmission. Therefore, it is important to analyze the vibration characteristic of the HDD actuator that consists of the VCM part, E-block and pivot bearing. In this paper, vibration modes of the HDD actuator are investigated the using finite element and experimental modal analyses methods. To develop a detailed finite element model, finite element models of each components of the actuator assembly are constructed and tuned to the results of the EMA. The VCM coil is modeled as an equivalent finite element model that has an orthotropic material property using auto-model updating program. Auto-model updating program with improved sensitivity based iterative method is applied to build a detailed finite element model using the result of the EMA. A detailed finite element model of the HDD actuator is then constructed and analyzed.